Skip to main content
Skip to content
Case File
efta-efta00612233DOJ Data Set 9Other

ARS Export Supply / Little St. James

Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta00612233
Pages
2
Persons
0
Integrity
No Hash Available

Summary

Ask AI About This Document

0Share
PostReddit

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
ARS Export Supply / Little St. James Dehumidification Control Description - The existing facility is receiving a new air-cooled chiller to handle temperature and dehumidification for the facility library and temperature for the island manager's office; the island mangers office will also receive a zero flow damper to stop air flow when temperature is satisfied. EMSBD has been asked to provide DDC mechanical control hardware and sequencing to accomplish said control parameters. Proposed Solution - EMSBD will provide a Small Building Controller and a Universal Unitary Controller 8s (both manufactured and warranted by HI Solutions, Inc.) to accomplish aforementioned control sequencing. The newly installed DDC system will control: chiller supply water temperature, chiller start/stop enable, chiller demand limit - via dry contact closure on chiller proprietary controls. The DDC system will control the island managers office temperature via analog control output to damper actuator (actuator provided by others) through analog output voltage / current signal from DDC. The damper adjustment will control airflow and subsequently temperature. Airflow will be set to a minimum adjustment to make certain that there is always fresh air in the space. The office temperature will be averaged with the library temperature (taking the active humidity value) to provide chill water setback temperature. Ambient air temperature adjustment for the island manger's office will be provided through web based interface and local access through wall-mounted temperature adjustment module in the office. The DDC system will control temperature and dehumidification in the library through the adjustment of the chiller supply water temperature and cycling of the strip heaters in the supply air duct. If available, air handler blower speed will be controlled via analog output signal from DDC. If the owner provided chiller has BACnet IP access available, the DDC system will provide available BACnet points and statuses via web-based interface. A web-based graphical users interface will be provided via the DDC small building controller. The GUI will be customized for the users specific needs. Coordination with the facility network administrator will be required to integrate the GUI into the network. It is highly recommended that a VPN/VNC access be configured for short- term use; this access would enable EMSBD to remotely assist in/troubleshoot system issues with quick response times. EMS by Design, tic 6110 Cedorcrest Road Suite 350 #275 • (770)542-9114 EFTA00612233 Sequencing of mechanical equipment PID loops will be 'tuned' while onsite installation is taking place, Although a target of 50/55% humidity is the goal, facility structure may come into play e.g., constant volume air handlers with fixed outside air, etc. EMSED will qualify and commission finished installation with ARS (and a representative of the owner if requested). All work to be performed within this scope is software based or specific to low voltoge termination on u CLASS II control system. As suck It is assumed that permitting is not necessary therefore it will not be covered within the scope of this proposal. if it is determined Not permitting is necessary, all permitting costs will be billed Installation of cabling will be completed per NEC and local code Accommodations and transportation costs while ante are not included within the scope of this proposal; arrangements for these expenses have been mode with ARS Shipping earn for equipment are not included within the scope of this proposal; arrangements have been modeler these expenses with ARS EMS by Design, LW 6110 Cedorcrest Rood Suite 350 #275 (770) 542-9114 EFTA00612234

Technical Artifacts (2)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

Phone(770) 542-9114
Phone(770)542-9114

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.