Skip to main content
Skip to content
Case File
efta-efta00926250DOJ Data Set 9Other

From: Richard Kahn

Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta00926250
Pages
3
Persons
0
Integrity

Summary

Ask AI About This Document

0Share
PostReddit

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
From: Richard Kahn To: "Jeffrey E." <[email protected]> Subject: Fwd: LSJ RO profibus Date: Fri, 22 Jun 2018 20:59:45 +0000 Richard Kahn HBRK Associates Inc. 575 Lexington Avenue 4th Floor New York NY 10022 tel fa, ce ] Begin forwarded message: From: brice gordon Subject: Re: LSJ RO profibus Date: June 22, 2018 at 2:17:51 PM EDT To: Richard Kahn < Cc: michael gliddenin No I need to be there while they remote And I haven't had the time to dedicate to this. Sent from my iPhone On Jun 22, 2018, at 2:08 PM, Richard Kahn > wrote: has this been resolved? please advise thank you Richard Kahn HBRK Associates Inc. 575 Lexington Avenue 4th Floor New York, NY 10022 tel fa cel EFTA00926250 On Jun 21, 2018, at 7:07 AM, brice gordon > wrote: good morning will reset team viewer in 10 minutes also confirm status of Heaters in each location thank you On Thu, Jun 21, 2018 at 7:01 AM, Tony Bell > wrote: Brice, Good morning. I was unable to remote into the PC at LSJ. The TeamViewer password changed overnight. From the picture you sent of the repeater in the control cabinet, you still do not have communication with the intake panel. There are 2 Amber LEDs behind the clear window in the center of the repeater. From your picture only the top LED (DPI) is illuminated. The top LED being ON is showing that there is PROFIBUS communication coming into the top of the repeater, the bottom LED (DP2) being OFF is showing that there is no communication leaving the bottom of the repeater. This means there is no communication happening between the repeater in control cabinet and the remote I/O in the intake panel. Possible causes are: The remote I/O in the intake panel is damaged, the repeater in the intake panel is damaged, the repeater in the main control cabinet is damaged, all 3 are damaged, or bad cabling or connections. <image001.png> From: brice gordon Sent: Wednesday, June 20, 2018 3:15 PM To: Dean Bedford Subject: LSJ RO profibus The Saint James Group USVI EFTA00926251 Ph: EFTA00926252

Technical Artifacts (1)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.