Skip to main content
Skip to content
Case File
efta-efta01198319DOJ Data Set 9Other

1 OF 2

Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta01198319
Pages
3
Persons
0
Integrity

Summary

Ask AI About This Document

0Share
PostReddit

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
1 OF 2 150526 WRO BBJ PIC0082015 NOT SUBMITTED YET iii WORK REQUEST ORDER PICTON II LTD VP-BBJ I B737-72U I SN 29273 I YG006 AFT AFL E1T E1C E2T E2C I APUT I APUC TO: FROM (CAM): Seyidi Ersevik Steve Wilson COMPANY: Jet Aviation Geneva FAX NUMBER: DATED: 26.05.2014 QUOTATION REFERENCE: N/A EMAIL ADDRESS: WORK REQUEST ORDER NUMBER: [email protected] PIC0082015 ITEM DESCRIPTION W/O ENTRY SIGNATURE 1. WHILE AIRCRAFT IS NOT IN MAINTENANCE: Perform "Aircraft Active Storage once per week. Engines / APU should be run and if possible aircraft taxied every 2 weeks. GPU to be connected every week for at least 45 minutes. NOTE 1: Breaks and Reverse Thrust to be activated as often as possible. NOTE 2: All Active Storage activities to be signed off individually in the Flight Log with relative DATES showing in the WP. New Flight Log pages to be printed as required. 2. Perform Engine Lip polishing and protection as required - every 2 weeks to check on condition please. 3. Comply with Due Maintenance CAMP WO attached - "VP-BBJ MONTHLY JUN 2015". 4. Perform with NDB Update. 5. THANK YOU EXPECTED ARRIVAL: 05.06.2015 REQUESTED AVAILABILITY: 30.06.2015 CONTINUED AIRWORTHINESS MANAGEMENT (on behalf of PICTON II Ltd) Qjet Aero I Switzerland I [email protected] I Tel EFTA01198319 2 OF 2 150526 WRO BB] PIC0082015 NOT SUBMITTED YET WORK REQUEST ORDER INSTRUCTIONS RELEVANT - CERTIFICATE OF RELEASE TO SERVICE (CRS) 1. After entry of Work Request Items into MRO system, Planning or Technical Support shall sign in the allocated space. Signature indicates that request(s) have been transferred to the actual project. 2. Item numbers showing "*" have been amended/added after original order was issued. 3. Certificate of Release to Service (CRS) shall refer Work Request Order Number and encompass all requested items unless otherwise specified or communicated. 4. Work Order entries (items) shall detail maintenance reference/specific chapters in all cases. Generic references and vague statements will not be accepted. AMM revision status shall also be indicated. 5. CRS shall comprise Flight Log Entry/Stamp/Signature and printed Certificate for Aircraft/Engine/APU Logbook(s). INSTRUCTIONS RELEVANT - CONTINUED AIRWORTHINESS MANAGEMENT 1. Before aircraft departure CRS, WO and Flight Log Entry shall be scanned and sent to the Continued Airworthiness Manager (CAM) for review. 2. After project closing, all CAMP Cards including CRS shall be scanned and sent to CAMP SYSTEMS for update within 5 working days. 3. Original Work Package documents shall be handed to the Operator or CAM as arranged. Note: There is no requirement for originals/copies of procedures used during maintenance to be provided. CONTINUED AIRWORTHINESS MANAGEMENT (on behalf of PICTON II Ltd) Qjet Aero I Switzerland I [email protected] I Tel: EFTA01198320 CAMP Work Order Contents Report SERIAL: 29273 (YG006) REGNO : VP-BBJ MODEL NAME : BBJ 737-700IGW/-800/-900ER WORK ORDER #: VP-BBJ MONTHLY JUN 2015 DATE IN : UTC:03-Jun-2015 12:00 AM DATE OUT : UTC:12-Jun-2015 12:00 AM ICAO : SERVICE CENTER : JET AVIATION (GENEVE) S.A. SORT ITEM NO DESCRIPTION STATUS COMPLIANCE NEXT DUE TIME REMAINING 1.0 05-00014 ACTIVE STORAGE PROCEDURE OPEN 2.0 050060 MONTHLY CHECK OPEN 2.1 267001 VISUAL INSPECT PORTABLE HALON FIRE EXTINGUISHERS FOR GENERAL CONDITION AND SERVICEABILITY OPEN 2.2 32.36000 VISUAL CHECK NOSE AND MAIN LANDING GEAR TIRES MD WHEELS FOR CONDITION AND WEAR. OPEN 2.3 330040 CHECK EXTERIOR LIGHTING FOR PROPER OPERATION OPEN 2.4 351040 PERFORM CREW OXYGEN SERVICING OPEN 2.5 290040 PERFORM HYDRAULIC OIL LEVEL SERVICING OPEN 2.6 240040 PERFORM IDG OIL LEVEL SERVICEING OPEN 2.7 490040 PERFORM MU OIL LEVEL SERVICING OPEN 2.8 2741-00 PERFORM REPETITIVE GV INSPECTION OF STABILIZER CONTROL CABLE AREA MARKED WITH RED PAINT IN OPEN THE AFT/LOWER FUSELAGE REGION, FOR CONDITION DETERIORATION. 2.9 24.10000 OPERATIONAL CHECK OF THE STANDBY POWER CONTROL UNIT (SPCU). OPEN 2.10 32.35000 CHECK NOSE AND MAIN LANDING GEAR TIRES FOR PROPER INFLATION, SERVICE AS REQUIRED OPEN 2.11 256151 INSPECT SMOKE GOGGLES OPEN 2.14 737.32-1448 TABLE 1.1 LUBRICATE LANDING GEAR - MAIN LANDING GEAR - FORWARD AND AFT TRUNNION PIN ASSEMBLIES OPEN INSPECTION MD CHANGE, SERVICE BULLETIN THE MLG FORWARD AND AFT TRUNNION PIN ASSEMBLIES FOR ALL AIRPLANES 3.0 252501 VISUALLY CHECK FORWARD ENTRY DOOR EMERGENCY ESCAPE SLIDE PRESSURE BOTTLE FOR PROPER OPEN PRESSURE 4.0 252502 VISUALLY CHECK FORWARD SERVICE DOOR EMERGENCY ESCAPE SLIDE PRESSURE BOTTLE FOR PROPER OPEN PRESSURE 5.0 252503 VISUALLY CHECK AFT ENTRY DOOR EMERGENCY ESCAPE SLIDE PRESSURE BOTTLE FOR PROPER PRESSURE OPEN 6.0 252504 VISUALLY CHECK AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE PRESSURE BOTTLE FOR PROPER PRESSURE OPEN 7.0 347101 UPDATE NAV DATABASE OPEN Prepared By: Date: Approved By: Date: 03-JUN-2015 © CAMP SYSTEMS 1 of 1 EFTA01198321

Technical Artifacts (6)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

Wire RefREFERENCE
Wire Refreference
Wire Refreferences

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.