Skip to main content
Skip to content
Case File
efta-efta01216572DOJ Data Set 9Other

SIEMENS

Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta01216572
Pages
140
Persons
0
Integrity

Summary

Ask AI About This Document

0Share
PostReddit

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
SIEMENS ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23, OXYMAT 61 Schnittstelle / Interface PROFIBUS DP / PA Beschreibung / Description Detektor 1 Detektor 2 Detektor 3 Detektor 4 SIMATICi a Device Management sty ial 1 Transducer -Block Sensor 1 signal 2 Transducer Block Sensor 2 sty 'al 3 Transducer Block -NO Sensor 3 4 signal 1 A5E00054148-03 4 4 Physical Block , Func ion Block Analog Input 1 Function Block Analog Input 2 Transducer -Block Sensor 4 4 Func Ion Block Analog Input 3 Function Block Analog Input 4 Function Block Digital Output AUTOCAL CFC-diagnosis-tool PCS 7 02 / 2002 EFTA01216572 The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights created by the granting of patents or registration of a design are reserved. Technical data are subject to change without notice. Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadensersatz. Alle Rechte vorbehalten, insbesonders für den Fall der Patenterteilung oder GM.Eintragung. Technische Änderungen vorbehalten. ULTRAMAT, OXYMAT, CALOMAT, SIPAN are Siemens registrated trademarks. All other product or system names are (registered) trademarks of their respective owners and must be treated accordingly. According to the German law an units in measuring technology, data in inches only apply to devices for export. ULTRAMAT, OXYMAT, CALOMAT, SIPAN sind Marken der Siemens AG. Die übrigen Bezeichnungen in diesem Handbuch können Marken sein, deren Benutzung durch Dritte für deren Zwecke die Rechte der Inhaber verletzen können. Die Angaben in Zoll(inch) gelten gemäß dem Gesetz über Einheiten im Messwesen nur für den Export. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 1 OXYMAT 61 2 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148.03 EFTA01216573 DEUTSCHER TEIL 1. HINWEISE FUR DEN BETREIBER 7 1.1 SICHERHEITSTECHNISCHE HINWEISE 8 1.2 PROFIBUS EIGENSCHAFTEN 10 1.2.1 PROFIBUS-PA 10 2. MONTAGEHINWEISE 11 2.1 BUSANSCHLUSS BEI ULTRAMAT / OXYMAT / CALOMAT 6 IM FELDGEHÄUSE 11 2.2 BUSANSCHLUSS BEI ULTRAMAT / OXYMAT / CALOMAT 61 OXYMAT 61 EINSCHUB 12 2.3 BUSANSCHLUSS BEI ULTRAMAT 23 13 2.4 PROFIBUS-PA BUSANSCHLUSS-STECKVERBINDER 14 2.4.1 Pin-Belegung PROFIBUS-PA Busanschluss-Steckverbinder 14 2.4.2 PROFIBUS — PA Kabel 14 2.5 PROFIBUS-DP BUSANSCHLUSS-STECKVERBINDER 15 2.5.1 Pin-Belegung PROFIBUS-DP Busanschluss-Steckverbinder 16 2.5.2 PROFIBUS — DP Kabel 16 2.6 PIN-BELEGUNG BINÄREINGÄNGE UND RELAISAUSGÄNGE 17 2.6.1 Pin-Belegung ULTRAMAT 6 E/OXYMAT 6 E/CALOMAT 6 E/OXYMAT 61 17 2.6.2 Pin-Belegung ULTRAMAT 23 18 2.6.3 Pin-Belegung ULTRAMAT 6 F/ OXYMAT 6 F /CALOMAT 6 F 19 2.7 AUFBAU DER OPTIONSBAUGRUPPE 20 2.8 EINBAU DER OPTIONSBAUGRUPPE (NACHRÜSTUNG 20 2.8.1 Einbau der Optionsbaugruppe ULTRAMAT/OXYMATICALOMAT 6 Einschub/OXYMAT 61 21 2.8.2 Einbau der Optionsbaugruppe ULTRAMATIOXYMATICALOMAT 6 Feldgehäuse 22 2.8.3 Einbau der Optionsbaugruppe ULTRAMAT 23 23 3. NUTZDATEN UBER DEN PROFIBUS 24 3.1. PROFIL BEI ULTRAMAT, OXYMAT UND CALOMAT 25 3.1.1 Transducer Block bei ULTRAMAT, OXYMAT und CALOMAT 26 3.1.2 Analog Input Block bei ULTRAMAT, OXYMAT und CALOMAT 27 3.1.3 Zyklische Datenübertragung /Messwert-Status 28 3.1.4 Discrete Output Block bei ULTRAMAT, OXYMAT und CALOMAT 30 3.1.5 Nutzdaten Discrete Output Block beim ULTRAMAT, OXYMAT und CALOMAT 30 3.1.6 Physical Block bei ULTRAMAT, OXYMAT und CALOMAT 32 3.1.7 Spezifische Parameter im Physical Block 34 4. INBETRIEBNAHME FUNKTIONEN/BEDIENUNG UBER PROFIBUS PA. 36 5. BEDIENUNG 47 5.1. EINSTELLEN DER STATIONSADRESSE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / OXYMAT 61 47 5.2. EINSTELLEN DER STATIONSADRESSE ULTRAMAT 23 48 6. WARTUNG 49 6.1. RÜCKLIEFERUNG 49 6.2. FIRMWARE 50 6.2.1 Firmware ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23 und OXYMAT 61 50 ULTRAMAT 6 / OXYMAT 6 I CALOMAT 6 I ULTRAMAT 23 / OXYMAT 61 3 Schnittstelle PROFIBUS DP / PA Interface ME00064148-03 EFTA01216574 7. ANHANG 51 7.2. BEDIENUNG MIT SIMATIC PDM 51 7.3. GSD GERATESTAMMDATEI 51 7.3 TECHNISCHE DATEN 51 7.4. DIAGNOSEINFORMATION 52 7.4.1 Diagnoseinformation ULTRAMAT 6 52 7.4.2 Diagnoseinformation OXYMAT 6 and OXYMAT 61 53 7.4.3 Diagnoseinformation CALOMAT 6 54 7.4.4 Diagnoseinformation ULTRAMAT 23 55 7.5. OBJEKTTABELLEN 56 7.5.1 Device Managment 56 7.5.2 Function Block At 1 57 7.5.3 Transducer Block TB 1 59 7.5.4 Physical Block 60 7.5.5 Function Block Al 2 62 7.5.6 Transducer Block 2 64 7.5.7 Function Block Al 3 65 7.5.8 Transducer Block TB 3 67 7.5.9 Function Block Al 4 68 7.5.10 Transducer Block TB 4 70 7.5.11 Function Block DO 71 ULTRAMAT 6 / OXYMAT 6 / CALMAT 6 / ULTRAMAT 23 / OXYMAT 61 4 Schnittstelle PROFIBUS DP / PA Interface ME00064148-03 EFTA01216575 ENGLISH PART 1. INFORMATION FOR THE USER 73 1.1. SAFETY NOTES 74 1.2. PROFIBUS PROPERTIES 76 1.2.1 PROFIBUS-PA 76 2. ASSEMBLY INFORMATION 77 2.1. Bus CONNECTION FOR ULTRAMAT / OXYMAT / CALOMAT 6 IN FIELD HOUSING 77 2.2 Bus CONNECTION FOR ULTRAMAT / OXYMAT / CALOMAT 6 / OXYMAT 61 MODULE 78 2.3 Bus CONNECTION FOR ULTRAMAT 23 79 2.4 PROFIBUS-PA Bus CONNECTORS 80 2.4.1 Pin Assignment PROFIBUS-PA Bus Connector 80 2.4.2 PROFIBUS-PA Cable 80 2.5 PROFIBUS-DP Bus CONNECTORS 81 2.5.1 Pin Assignment of PROFIBUS-DP Bus Connector 82 2.5.2 PROFIBUS-DP Cable 82 2.6 PIN ASSIGNMENT ON BINARY AND RELAY OUTPUTS 83 2.6.1 ULTRAMAT 6 E/OXYMAT 6 E/CALOMAT 6 E/OXYMAT 61 Pin Assignment 83 2.6.2 ULTRAMAT 23 Pin Assignment 84 2.6.3 ULTRAMAT 6 F/OXYAAAT 6 F/CALOMAT 6 F Pin Assignment 85 2.7 OPTIONAL MODULE SETUP 86 2.8 INSTALLING THE OPTIONAL MODULE (RETROFITTING) 86 2.8.1 Installing the Optional ULTRAMAT / OXYMAT/ CALOMAT 6 Module and OXYMAT 61 87 2.8.2 Installing the Optional ULTRAMAT/ OXYMAT/ CALOMAT 6 Field Housing Module 88 2.8.3 Installing the ULTRAMAT 23 Optional Module 89 3. TRANSMITTING USER DATA VIA PROFIBUS 90 3.1. PROFILE FOR ULTRAMAT, OXYMAT AND CALOMAT 91 3.1.1 Transducer Block with ULTRAMAT, OXYMAT and CALOMAT 92 3.1.2 Analog Input Block with ULTRAMAT, OXYMAT and CALOMAT 93 3.1.3 Cyclical data transmission/measured value status 94 3.1.4 Discrete Output Block with ULTRAMAT, OXYMAT and CALOMAT 96 3.1.5 User Data Discrete Output Block with ULTRAMAT, OXYMAT and CALOMAT 97 3.1.6 Physical Block with ULTRAMAT, OXYMAT and CALOMAT 98 3.1.7 Specific parameters physical block 100 4. COMMISSIONING FUNCTIONS/OPERATIONS USING PROFIBUS PA 102 5. OPERATION 113 5.1. SETTING THE STATION ADDRESS ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / OXYMAT 61 113 5.2. SETTING THE STATION ADDRESS ULTRAMAT 23 114 6. MAINTENANCE 115 6.1. RETURN 115 6.2. FIRMWARE 116 6.2.1 ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23 and OXYMAT 61 Firmware 116 ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 5 Schnittstelle PROFIBUS DP / PA Interlace A5E00054148-03 EFTA01216576 7. APPENDIX 117 7.1. OPERATION WITH SIMATIC PDM 117 7.2. DEVICE DATA BASE FILE (GSD) 117 7.3. TECHNICAL DATA 117 7.4. DIAGNOSTIC INFORMATION 118 7.4.1 ULTRAMAT 6 Diagnostic Information 118 7.4.2 OXYMAT 6 and OXYMAT 61 Diagnostic Information 120 7.4.3 CALOMAT 6 Diagnostic Information 120 7.4.4 ULTRAMAT 23 Diagnostic Information 121 7.5. COMPLETE OBJECT LIST 122 7.5.1 Device Managment 122 7.5.2 Function Block Al 1 123 7.5.3 Transducer Block TB 1 125 7.5.4 Physical Block 126 7.5.5 Function Block Al 2 128 7.5.6 Transducer Block 2 130 7.5.7 Function Block Al 3 131 7.5.8 Transducer Block TB 3 133 7.5.9 Function Block Al 4 134 7.5.10 Transducer Block TB 4 136 7.5.11 Function Block DO 137 ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 6 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216577 1. Hinweise für den Betreiber Die Beschreibung gilt für die die ULTRAMAT 6 OXYMAT 6 ULTRAMAT/OXYMAT 6 CALOMAT 6 ULTRAMAT 23 OXYMAT 61 SIEMENS - Analysengeräte: 7M82111, 7MB2112, 7MB2117, 7MB2121, 7MB2123, 7MB2124, 7MB2127, 7MB2128 7M82011, 7MB2017, 7MB2021, 7MB2027 7M82023, 7MB2028 7M82511, 7MB2521 7M82331, 7MB2333, 7MB2334 7M82001 In dieser Beschreibung werden wichtige Hinweise, Ergänzungen und Korrekturen zu den Gerätehandbüchern gegeben. Der Aufbau von PROFIBUS Netzwerken ist mit Komponenten aus dem Katalog ST PI durchzuführen. Bestellnummern: E86060-K4660-A101-A3 (deutsch) bzw. E86060-K4660-A101-A3-7600 (englisch) Informationen zum Aufbau von PROFIBUS-Netzen sind im Handbuch "PROFIBUS-Netze" zu finden: Bestellnummern: 6GK1970-5CA10-0AA0 (deutsch) 6GK1970-5CA10-0AA1 (englisch). 6GK1970-5CA10-0AA2 (französisch) 6GK1970-5CA10-0AA3 (spanisch) 6GK1970-5CA10-0AA4 (italienisch) Informationen zum Aufbau von PROFIBUS-Komponenten bei SIEMENS unter: http://www.ad.siemens.de/profibus/html 00/ueber.htm: Weitere Informationen können auch bei der Profibus Nutzer Organisation oder über das Internet unter bezogen werden. Anschrift: PROFIBUS Nutzerorganisation Haid-und-Neu-Str. 7 D-76131 Karlsruhe Tel.: ++49 721 / 96 58 590 Fax: ++49 721 / 96 58 589 ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 7 Schnittstelle PROFIBUS DP I PA Interface A5E00054148-03 EFTA01216578 1.1 Sicherheitstechnische Hinweise Bedeutung der Hinweise A Warnung bedeutet, daß Tod, schwere Körperverletzung oder erheblicher Sachschäden eintreten können, wenn die entsprechenden Vorsichtsmaßnahmen nicht getroffen werden. Hinweis ist eine wichtige Information über das Produkt, dessen Handhabung oder den jeweiligen Teil der Dokumentation, auf den besonders aufmerksam gemacht werden soll. Einführung Die Beschreibung gilt im Sinne der Richtlinie des Rates der Europäischen Gemeinschaft vom 23. März 1994 (94/9/EG) als Betriebsanleitung. In ihr werden die grundlegenden Schritte zu Montage, Anschluß und Inbetriebsetzung beschrieben. Diese Anleitung ist eine Ergänzung zum Gerätehandbuch. Die Gerätehandbücher sind im Lieferumfang der Gasanalysengeräte enthalten. Diese Beschreibung ist fester Bestandteil des Lieferumfangs. Sie enthält aus Gründen der Übersichtlichkeit nicht sämtliche Details zu allen Ausführungen des beschriebenen Produktes und kann auch nicht jeden erdenklichen Fall der Aufstellung, des Betriebes, der Instandhaltung und des Einsatzes in Systemen berücksichtigen. Sollten Sie weitere Informationen benötigen oder sollten Probleme auftreten, die in dieser Unterlage nicht ausführlich genug behandelt werden, dann fordem Sie bitte die benötigte Auskunft von Ihrer örtlichen bzw. zuständigen Siemens-Niederlassung an. Insbesondere vor einem Einsatz des Geräts für neue Anwendungen, zum Beispiel in Forschung und Entwicklung, empfehlen wir eine Durchsprache Ihrer Applikation mit unserer Fachberatung" Gefahrloser Betrieb Die Geräte und die Baugruppe haben das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen. Um diesen Zustand zu erhalten und um einen gefahrlosen Betrieb des Gerätes sicherzustellen, sind die in dieser Anleitung gegebenen Hinweise und Warnvermerke vom Anwender zu beachten. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 1 OXYMAT 61 8 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216579 Qualifiziertes Personal im Sinne dieser Anleitung sind Personen, die mit Montage, Inbetriebnahme und Betrieb dieses Produktes vertraut sind und über ihrer Tätigkeit entsprechende Qualifikationen verfügen, wie z. B.: Ausbildung oder Unterweisung bzw. Berechtigung, Stromkreise und Geräte bzw. Systeme gemäß den aktuellen Standards der Sicherheitstechnik ein— und auszuschalten, zu erden und zu kennzeichnen; 3 Ausbildung oder Unterweisung gemäß den aktuellen Standards der Sicherheitstechnik in Pflege und Gebrauch angemessener Sicherheitsausrüstungen; 3 Schulung in Erster Hilfe; O Für den Explosionsschutz: Ausbildung oder Unterweisung bzw. Berechtigung, Arbeiten an elektrischen Kreisen explosionsgefährdeter Anlagen durchzuführen. A Warnung Die Geräte dürfen nur von qualifiziertem und sachkundigem Personal montiert und in Betrieb genommen werden. Auf die ggf. notwendige Beachtung von Sicherheitsvorschriften für explosionsgefährdete Anlagen wird hiermit ausdrücklich hingewiesen. lir Hinweis ic A Der einwandfreie und sichere Betrieb der Geräte setzt sachgemäßen Transport, fachgerechte Lagerung, Aufstellung und Montage sowie sorgfältige Bedienung und Instandhaltung voraus. Hinweis EMV Zur Gewährleistung der angegebenen elektromagnetischen Verträglichkeit müssen geschirmte Leitungen verwendet werden und die Schirme im Buchsen- bzw. Stecker-Gehäuse aufgelegt werden. Hinweis Aufbau von PROFIBUS Netzwerken Für den Aufbau von PROFIBUS Netzwerken sind folgende Handbücher zu beachten: Buskopplung DP/PA Ausgabe 2 Bestellnummer 6ES7 157-0AA00-8AA0 sowie Handbuch für PROFIBUS-Netze Bestellnummer 6GK1 970-5CA10-0AA0 (deutsch) bzw. 6GK1 970-5CA10-0AA1 (englisch) Dokumentationspaket Bestellnummer 6ES7 398-8RA00-8AA0 Warnung Geräte der Zündschutzart "Eigensicherheit" verlieren ihre Zulassung, sobald sie an Stromkreisen betrieben wurden, die nicht den in der EG-Baumusterprüfbescheinigung festgelegten Anforderungen entsprechen. ULTRAMAT 61OXYMAT 6 / CALOMAT 6 / ULTRAMAT 231 OXYMAT 61 9 Schnittstelle PROFIBUS DP t PA Interface A5E00054148.03 EFTA01216580 1.2 PROFIBUS Eigenschaften Der PROFIBUS (PROcess Field BUS) ist ein offenes und genormtes Kommunikationssystem für die Automatisierungstechnik. Mit Optionsbaugruppen besteht die Möglichkeit die SIEMENS- Gasanalysengeräte ULTRAMAT, OXYMAT und CALOMAT entweder an den PROFIBUS-PA oder an den PROFIBUS-DP anzukoppeln. 1.2.1 PROFIBUS-PA PROFIBUS-DP - Kommunikationsprotokoll IEC-1158-2 Übertragungstechnik PROFIBUS-PA Die Optionsbaugruppe A5E00015899 Exi ermöglicht die eigensichere Ankopplung an PROFIBUS-PA Die Optionsbaugruppe A5E00034504 ermöglicht die nicht-eigensichere Ankopplung an PROFIBUS-PA Die Optionsbaugruppe A5E00019145 ermöglicht die Ankopplung an den PROFIBUS-DP. Hinweis Explosionsschutz Die Optionsbaugruppe A5E00015899 Exi ist ein zugehöriges Betriebsmittel und darf nur in Geräten ULTRAMAT 6 F / OXYMAT 6 F / CALOMAT 6F mit der Schutzart EExp[ia/ib] IIC T4 montiert werden. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 10 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216581 2. Montagehinweise 2.1 Busanschluß bei ULTRAMAT / OXYMAT / CALOMAT 6 im A Feldgehäuse 37-polige Sub-D-Buchse für zusätzliche Binäreingänge und Relaisausgänge: Wie Option Autocal Warnung 9-poligen Sub-D-Buchsenleiste PROFIBUS-DP Anschluß 9-poligen Sub-D-Stiftleiste PROFIBUS-PA Anschluß ( Exi oder nicht Exi ) In Feldgeräten mit Profibusanschluß, die in explosionsgefährdeten Bereichen eingesetzt werden, darf nur die Baugruppe A5E 00015899 Exi verwendet werden. Die Ein- und Ausgänge der 37-poligen Sub-D-Buchse dürfen nur mit besonderem Schutz angeschlossen und benutzt werden. (Siehe Gerätehandbücher OXYMAT 6 / ULTRAMAT 6 / CALOMAT 6.) Die einschlägigen Bestimmungen für das Errichten und Betreiben von Anlagen in diesen Bereichen sind zu beachten. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 11 EFTA01216582 2.2 Busanschluß bei ULTRAMAT / OXYMAT / CALOMAT 6 Einschub und OXYMAT 61 7- Nur bei ULTRAMAT/OXYMAT und ULTRAMAT 6 E Zweikanalgerät Geräterückseite 9-poligen Sub-D-Buchsenleiste PROFIBUS-DP Anschluß 9-poligen Sub-D-Stiftleiste —I PROFIBUS-PA Anschluß (nicht Exi) 37-polige $ub-D-Buchse für zusätzliche Binäreingänge und Relaisausgänge: Wie Option Autocal ULTRAMAT 6 f OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 f OXYMAT 61 12 Schnittstelle PROFIBUS DP I PA Interface A5E00054148-03 EFTA01216583 Geräterückseite 2.3 Busanschluß bei ULTRAMAT 23 9-poligen Sub-D-Buchsenleiste PROFIBUS-DP Anschluß 9-poligen Sub-D-Stiftleiste PROFIBUS-PA Anschluß (nicht Exi) 37-polige Sub-D-Buchse für zusätzliche Binäreingänge und Relaisausgänge: Wie Option Autocal ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 13 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216584 4.2 PROFIBUS-PA Busanschlußsteckverbinder Es ist der 9-polige Sub-D-Buchsensteckverbinder notwendig, der dem Gerät/der Option beiliegt. Hier kann das Buskabel mit einer Lötverbindung angeschlossen werden. Steckverbinder mit einer lösbaren Klemmenverbindung können zum Beispiel von Firma: Phoenix Contact Typ: SUBCON 9/F-SH Artikel-Nr.: 27 61 49 9 bezogen werden. 2.4.1 Pin-Belegung PROFIBUS-PA Busanschlußsteckverbinder Funktion PIN PA-P ( + ) 3 PA-N ( - ) 7,8 NC (Not connected) 1,2,4,5,6,9 2.4.2 PROFIBUS - PA Kabel SIEMENS - Bestellnummer: (Leitungen für die FastConnect-Technik) 6XV1 830-5CH10 (blau) für Ex-Anwendungen 6XV1 830-5DH10 (schwarz) für Nicht-Ex-Anwendungen Ce Hinweis Der Kabelschirm ist flächig im Steckergehäuse anzuschließen. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 / OXYMAT 61 14 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216585 2.5 PROFIBUS-DP Busanschlußsteckverbinder Es ist der 9-polige Sub-D-Steckverbinder (Stiftleiste) notwendig, der dem Gerät/der Option beiliegt. Hier kann das Buskabel mit einer Lötverbindung angeschlossen werden. Steckverbinder mit einer lösbaren Klemmenverbindung können zum Beispiel von Firma: Phoenix Contact Typ: SUBCON 9/M-SH Artikel-Nr.: 27 61 50 9 bezogen werden. (111- Hinweis In diesem Steckverbinder sind keine Busabschlußwiderstände integriert. Auch andere Busanschlußstecker RS 485 sind für den PROFIBUS DP geeignet. SIEMENS - Bestelldaten: (Beispiele) 6GK1 500-0EA02 6ES7 972-OBA11 - OXAO 6ES7 972-0BA40 - OXAO 6ES7 972-0BA50- OXAO Hinweis axialer Kabelabgang, intern Reihenklemmen 90° Kabelabgang, intern Reihenklemmen mit schrägem Kabelabgang, intern Reihenklemmen 90° Kabelabgang, Schneidklemmen für FastConnect Leitungen Bei Anschluß von PROFIBUS-DP und Binäreingängen/Relaisausgängen ist der Verbinder mit axialem Kabelabgang zu verwenden. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 I OXYMAT 61 15 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216586 2.5.1 Pin-Belegung PROFIBUS-DP Busanschlußsteckverbinder Funktion PIN RxD/TxD-P 3 Datenleitung B CNTR-P 4 Richtungssteuerung DGND 5 Datenübertragungspotential (Masse zu 5V) VP 6 +5V für Busabschlußwiderstände, Optical Link Plug RxD/TxD-N 7,8 Datenleitung A NC nicht belegt Mr. Hinweis 1,2,9 Der Pin 7 ist mit der Datenleitung verbunden. Es dürfen keine Verbraucher angeschlossen werden. 2.5.2 PROFIBUS — DP Kabel SIEMENS- Bestelldaten: (Beispiel) 6XV1 830-0E10 (violett) auch für die FastConnect - Technik Hinweis Der Kabelschirm ist flächig im Steckergehäuse anzuschließen. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 16 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216587 2.6 Pin-Belegung Binäreingänge und Relaisausgänge 2.6.1 Pin-Belegung ULTRAMAT 6 E / OXYMAT 6 E / CALOMAT 6 E / OXYMAT 61 Eine detailierte Beschreibung ist dem jeweiligen Gerätehandbuch (Kapitel 2) zu entnehmen. DSUB 37F Funktion im Gerät M PIN r r I Funktion 1 GND 20 2 21 3 4 5 5 7 8 9 10 11 12 13 22 23 24 25 26 27 28 29 30 31 I Bemerkungen Relais 7 Relais 8 Relais 9 Relais 10 Relais 11 Relais 12 Relais 13 Relais 14 32 Digitaleingang 7...14 N Digitaleingang 7 33 Digitaleingang 8 - P Digitaleingang 9 - P 34 Digitaleingang 10 - P Digitaleingang 11 - P 35 Digitaleingang 12 - P Digitaleingang 13 - P 36 Digitaleingang 14 - P 18 NC (not connected) 37 NC (not connected) GND Kontaktbelastung: max. 24 V / 1A, AC/DC für dargestellte Relaiskontaktstellung ist Relais stromlos potentialfrei über Optokoppler "0'1 =OV (0..A,5V) "1" = 24 V ( 13...33V ) ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 17 EFTA01216588 2.6.2 Pin-Belegung ULTRAMAT 23 Eine detailierte Beschreibung ist dem jeweiligen Gerätehandbuch (Kapitel 3) zu entnehmen. DSUB 37F Funktion im Gerät M PIN Funktion Bemerkungen 1 GND 20 2 Relais 9 21 22 Relais 10 3 4 23 5 Relais 11 5 7 8 24 25 26 27 9 28 10 29 11 30 12 31 13 32 18 M _19 33 34 Relais 12 Relais 13 Relais 14 Relais 15 Relais 16 Kontaktbelastung: max. 24 V / 1A, AC/DC Ifür dargestellte Relaiskontaktstellung ist Relais stromlos 35 36 37 Digitaleingang 1...8 - N Digitaleingang 1 - P Digitaleingang 2 - P Digitaleingang 3 - P Digitaleingang 4 - P Digitaleingang 5 - P Digitaleingang 6 - P Digitaleingang 7 - P Digitaleingang 8 - P NC (not connected) NC (not connected) GND potentialfrei über Optokoppler "CV = OV (0..A,5V) "1" = 24 V ( 13...33V ) ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 18 EFTA01216589 2.6.3 Pin-Belegung ULTRAMAT 6 F / OXYMAT 6 F / CALOMAT 6F Eine detailierte Beschreibung ist dem jeweiligen Gerätehandbuch (Kapitel 2) zu entnehmen. Klemmenblock Funktion im Gerät 5 Klemme 2 Funktion GND 3 Relais 7 7 9 11 13 15 17 19 21 23 35 M 25 4 6 Relais 8 8 Relais 9 10 12 Relais 10 Relais 11 18 Relais 12 Relais 13 24 Relais 14 14 16 20 22 26 Digitaleingang 7...14 - N Digitaleingang 7 - P 28 Digitaleingang 8 - P Digitaleingang 9 - P 30 Digitaleingang 10 - P Digitaleingang 11 - P 32 Digitaleingang 12 - P Digitaleingang 13 - P 34 Digitaleingang 14 - P NC (not connected) 36 NC (not connected) 37 GND Bemerkungen Kontaktbelastung: max. 24 V / 1A, AC/DC für dargestellte Relaiskontaktstellung ist Relais stromlos potentialfrei über Optokoppler "0" = O V (0..A,5V) "1" = 24 V ( 13...33V ) ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 19 EFTA01216590 2.7 Aufbau der Optionsbaugruppe Flash- EEPROM Firmware LIMO MU A5E00019145 / A5E00034504 I A5E00015899 (Exi) Binäreingänge I Relaisausgänge 37-polige Sub-D-Buchse PROFIBUS-PA 9-polige Sub-D-Buchse PROFIBUS-DP 9-polige Sub-D-Stiftleiste 26-poliger Flachbandverbinder zur Grundplatte 2.8 Einbau der Optionsbaugruppe (Nachrüstung) Hinweis Unter Umständen ist ein Tausch der Firmware im Analysengerät erforderlich siehe Kapitel 6.2 Firmware Hinweis Bei Einschub-Geräten dürfen nur die Baugruppe A5E00034504 für die nicht-eigensichere Ankopplung an PROFIBUS-PA und die Baugruppe A5E00019145 für die Ankopplung an den PROFIBUS-DP eingebaut werden. ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 20 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148-03 EFTA01216591 2.8.1 Einbau der Optionsbaugruppe ULTRAMAT / OXYMAT / CALOMAT 6 E und OXYMAT 61 lir Hinweis Beim ULTRAMAT OXYMAT und ULTRAMAT 6 E Zweikanalgerät sind 2 PROFIBUS-Anschaltungen erforderlich Einbauanweisung: Gerät vom Netz trennen Gehäusedeckel abschrauben und abnehmen ggf. alte Optionsbaugruppe entfernen Baugruppe(n) in die Schiene am Boden einführen Baugruppe(n) mit den Schrauben M3 zwischen Steckern an der Rückwand befestigen Steckverbinder zur Grundplatte stecken Arretierungsbügel einlegen Gehäusedeckel wieder anschrauben Gerät mit PROFIBUS verbinden Gerät an Netz anschließen Optionsbaugruppen Grundplatte Kanal 1 Grundplatte Kanal 2 Rückwand ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148.03 Abb 2.1 21 EFTA01216592 2.8.2 Einbau der Optionsbaugruppe ULTRAMAT !OXYMAT / CALOMAT 6 Feld Einbau der Optionsbaugruppe ULTRAMAT / OXYMAT / CALOMAT 6 Feldgehäuse lir Hinweis Bei Geräten mit Feldgehäuse darf nur in Exp[ia/ibl - Geräten die Baugruppe A5E00015899 Exi für die eigensichere Ankopplung an PROFIBUS-PA eingebaut werden. Bei allen anderen nicht Ex-Geräten dürfen nur die Baugruppe A5E00034504 für die nicht-eigensichere Ankopplung an PROFIBUS-PA bzw. A5E00019145 für die Ankopplung an den PROFIBUS-DP. eingebaut werden. Einbauanweisung: Gerät vom Netz trennen Linke Gehäusetür öffnen Blechabdeckung entfernen Blechkassette aus dem Gerät ausbauen ggf. alte Optionsbaugruppe entfernen Baugruppe in die Schiene einführen Baugruppe mit den Schrauben M3 zwischen Steckern an der Kassettenunterseite befestigen Blechwinkel auf die obere Kante der Optionsbaugruppe einhaken Steckverbinder zur Grundplatte stecken Verbindung von 37-poligem Sub-D-Buchse zur Klemmleiste im Gerät herstellen Blechkassette in das Gerät einbauen Blechabdeckung einbauen Gerät mit PROFIBUS verbinden Gerät an Netz anschließen Kassette Grundplatte Optionsbaugruppe ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 26-poriges Flachbandkabel stecken Abb 2.2 22 EFTA01216593 2.8.3 Einbau der Optionsbaugruppe ULTRAMAT 23 Olt Hinweis Beim ULTRAMAT 23 dürfen nur die Baugruppen A5E00034504 für die nicht-eigensichere Ankopplung an PROFIBUS-PA und die Baugruppe A5E00019145 für die Ankopplung an den PROFIBUS-DP. eingebaut werden. Gerät vom Netz trennen Gehäusedeckel abschrauben und abnehmen ggf. alte Optionsbaugruppe entfernen Baugruppe mit den Schrauben M3 zwischen Steckern an der Rückwand befestigen Baugruppe mit Kunststoffbolzen (Bestandteil Nachrüstsatz) an Gehäuseboden befestigen Steckverbinder zur Grundplatte stecken Gehäusedeckel wieder anschrauben Gerät mit PROFIBUS verbinden Gerät an Netz anschließen Rückwand I I I 11Mil El En Optionsbaugruppe Grundplatte Befestigungsbolzen 26-poliges Flachbandkabel stecken Abb 2.3 ULTRAMAT 6 OXYMAT 6 / CALMAT 6 / ULTRAMAT 23 I OXYMAT 61 23 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216594 3. Nutzdaten Ether den PROFIBUS Datenstrukturen deren Bedeutung sowie Funktionsumfang sind beim PROFIBUS-PA in den "PROFIBUS-PA Profilen" festgelegt. Die Profile sind in folgenden Dokumenten spezifiziert: PROFIBUS-PA Profile for Process Control Devices PROFIBUS-PA Profile for Process Control Devices PROFIBUS-PA Profile for Process Control Devices PROFIBUS-PA Profile for Process Control Devices PROFIBUS-PA Profile for Process Control Devices Bezugsquelle: Im Internet unter oder Anschrift: PROFIBUS Nutzerorganisation Haid-und-Neu-Str. 7 D-76131 Karlsruhe Tel.: ++49 721 / 96 58 590 Fax: ++49 721 / 96 58 589 Eine sehr informative Einfibrung ist im Internet unter http://home.t-online.de/home/hartmut.flaemig/pa_intro.htm zu finden. / General Requirements / Mapping to Fieldbus / Data Sheet Transmitter / Data Sheet Analyser /Data Sheet Discrete Output ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 ULTRAMAT 23 / OXYMAT 61 24 Schnittstelle PROFIBUS DP t PA Interface A5E00054148.03 EFTA01216595 3.1 Profil bei ULTRAMAT, OXYMAT und CALOMAT Blockmodell nach PROFIBUS-PA r ULTRAMAT, OXYMAT CALOMAT PROFIBUS PA Option. Device Physical Block Meßwertauf Transducer bereitungd Block Function Block Analog Input Meßwert = Eingangswert Ausgangswert -` PROFIBUS PA / Blockstruktur eines Gasanalysengerätes mit 4 Blocktypen, exemplarisch für einen Meßwert Hinweis Die komplette Objekttabelle der Blöcke befindet sich im Anhang Kapitel 7.5 Variante Transducer Blöcke Function Blöcke TB Al ( Analog Input ) DO ( Digital Output ) ULTRAMAT 6 mit 1 Komponente 1 1 1 ULTRAMAT 6 mit 2 Komponeneten 2 2 1 ULTRAMAT 23 mit 1 Komponente 1 1 1 ULTRAMAT 23 mit 2 Komponenten / 2 2 1 ULTRAMAT 23 mit 3 Komponenten / 3 3 1 ULTRAMAT 23 mit 4 Komponenten / 4 4 1 OXYMAT 6 1 1 1 CALOMAT 6 1 1 1 OXYMAT 61 1 1 1 1 Auch bei O2 (Sensor) handelt es sich um eine Komponente Bei ULTRAMAT 6 und ULTRAMAT 23 werden die Zuordnungen zu den Infrarot(IR)-Mess-Komponenten immer mit "1" beginnend in aufsteigender Folge belegt. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 25 EFTA01216596 Beim ULTRAMAT 23 ergeben sich auf Grund der O2 - Messkomponente(Sensor) folgende Möglichkeiten: Variante IR — Meßkomponente 1 IR — Meßkomponente 2 IR — Meßkomponente 3 O2 ( nur wenn vornanden) 7MB 2331 TB/Al 1 ------- ----- — TB/Al 2 7MB 2333 TB/Al 1 TB/Al 2 ---------- ------ TB/Al 3 7MB 2334 TB/Al 1 TB/Al 2 TB/Al 3 TB/Al 4 Welches Gas der Meßkomponente entspricht ist aus der MLFB-Nummer des Gerätes zu entnehmen. (Typenschild) 3.1.1 Transducer Block bei ULTRAMAT/OXYMAT/CALOMAT Der Analyser-Transducer Block erhält seinen Eingangswert vom ULTRAMAT/OXYMAT/CALOMAT Grundgerät. Dadurch werden die geräteabhängigen Funktionen von Sensoren, Messwerterfassung und —Verarbeitung von dem Function Block getrennt. Rel. Index Parameter Beschreibung 8 COMPONENT_NAME Name der Komponente 9 PV Messwert der an den AI-Block weitergegeben wird 10 PV_UNIT Einheit des Messwertes 11 PV_UNIT_TEXT Einheit in Textform 12 ACTIVE RANGE Aktueller Meßbereich / Immer "1". ULTRAMAT, OXYMAT, CALOMAT benutzen hier den grössten Messbereich (Kennlinienendwert) 13 AUTORANGE_ON Automatische Meßbereichsumschaltung TRUE/FALSE Hier ohne Bedeutung, da ULTRAMAT, OXYMAT, CALOMAT immer den grössten Messbereich (Kennlinienendwert) benutzen. 14 SAMPLING_RATE Zeit zwischen 2 Meßwertabtastungen 25 NUMBER_OF_RANGES Anzahl der Messbereiche / Immer nur ein Messbereich 26 RANGE _1 Messbereichanfangs und Endwert ("grösster Messbereich ") 34 POSITIONING_VALUE Wert (1 Byte) zum Auslösen der Autokalibrierung. Wird vom DO-Block nübernommen. 35 FEEDBACK Wert (1Byte) zum Rücklesen über den Zustand der Autokalibrierung (wird vom DO-Block-REEDBACK übernommen. ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 26 EFTA01216597 3.1.2 Analog Input Block bei ULTRAMAT, OXYMAT, CALOMAT Über den Anlog Input Block wird Messwert und Status für den Prozessbereitgestellt. Rel. Index Parameter Beschreibung 10 OUT Ausgangswert und —Status. Ergebnis des Analog Input Function Blocks 11 PV_SCALE Eingangsskalierung. Im Regelfall, der Meßbereich des Transducer Blocks. Der untere Wert (0%) wird auf 0 abgebildet, der obere Wert (100%) auf 1. 12 OUT_SCALE Ausgangsskalierung. Abbildung auf die anwenderspezifische physikalische Größe. 0 wird auf den unteren Wert (0%), 1 auf den oberen Wert (100%) abgebildet. Angabe der anwendungsspezifischen Einheit. 13 LIN_TYPE Auswahl der Kurvenform bei der Kennlinientransformation. 16 PV_FTIME Filterzeitkonstante t des digitalen Filters 1. Ordnung. 17 FSAFE_ TYPE Parametrieren der Sicherheitslage. Verhaften wird nur in der Betriebsart AUTO, wenn der Meß- oder Simulationswert mit einem schlechten Status (BAD) behaftet ist oder der aktuelle Modus O/S aktiv ist. • 0: Der Vorgabewert FSAFEVALUE wird für die Sicherheitslage verwendet. Der Status wird auf uncertain — substitude set angehoben. • 1: Der vor dem Ausfall letzte gültige Ausgangswert wird weiter verwendet. Der Status wird auf uncertain — last usable value angehoben. Gab es zuvor keinen gültigen Wert, so wird der Initialwert mit dem Status uncertain — initial value geliefert. • 2: Der Wert wird ungeachtet des schlechten Status' für die weitere Berechnung verwendet. Ist dieser Parameter nicht implementiert, verhält sich der Al wie bei • 1 beschrieben. 18 FSAFE_VALUE Vorgabewert für Sicherheitslage. 19 ALARM_HYS Grenzwerthysterese. Zur Vermeidung eines Alarmschwalls bzw. flauem von Meldeflags. Nach Überschreiten eines Grenzwertes muß sich der Wert die Hysterese in gegenläufiger Richtung bewegt haben, bevor die Grenzwertmeldung zurückgesetzt wird. 21 HI_HI_LIM Obere Alarmgrenze 23 HI_LIM Obere Vorwamgrenze 25 LO_LIM Untere Vorwamgrenze 27 LO_LO_LIM Untere Alarmgrenze 30 HI_HI_ALM Alarmstatusparameter für obere Alarmgrenze. 31 HI_ALM Alarmstatusparameter für obere Vorwamgrenze 32 LO_ALM Alarmstatusparameter für untere Vorwamgrenze. 33 LO_LO_ALM Alarmstatusparameter für untere Alarmgrenze. 34 SIMULATE Simulationswert und —status, Freigabe der Simulation. 35 OUT_UNIT_TEXT Hinterleg barer ASCII-Text, falls in OUT_SCALE die Einheit stextuelle Referenz" angegeben ist. ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 27 EFTA01216598 3.1.3 Zyklische Datenübertragung /Messwert-Status Es können folgende Nutzdaten zyklisch über den PROFIBUS ausgetauscht werden: Parametemame Bedeutung Richtung aus Sicht Gasanalysengerät Datentyp Länge in Bytes OUT Messwert und Status Ausgang DS-33 5 Datentyp DS 33: Genaue Beschreibung in PROFIBUS-PA Profile for Process Control Devices/General Requirements Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Analogwert in IEEE-Fließkomma Status Exponent Fraction MSB Bedeutung Status In der Datenstruktur DS-33 wird zusätzlich zu jedem der Messwerte synchron ein Statusbyte übertragen. Dieses Byte gibt in einem " Quality-Code" eine Qualitätsaussage zu diesem Wert. Das Statusbyte ist folgendermaßen aufgebaut. Genaue Beschreibung in PROFIBUS-PA Profile for Process Control Devices / General Requirements MSB 7 6 5 4 3 2 1 0 Quality Sub-Status Limits 0 0 bad schlecht 0 1 uncertain unsicher 1 0 good _gut 1 1 good (cascaded) gut (Kaskade) Der Sub-Status ist je nach Qualität unterschiedlich aus- dekodiert 0 0 ok 0 1 low limited Grenzwert unterschritten 1 0 high limited Grenzwert überschritten 1 1 constant Wert konstant ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP I PA Interface A5E00054148-03 28 EFTA01216599 Statuscodierung ULTRAMAT / OXYMAT / CALOMAT: Statuscodierung bei "QuaOM schlecht" Dez Hex Ursache Maanahme 11 08 Komponente fehit Konfiguration andem, Gerat mit dieser Komponente installieren 12 OC Geratefehler Mit SIMATIC PDM Fehler prazisieren / Gerat tauschen 31 1F auger Betrieb ( Ersatzwert, letzter gfiltiger Wert, Wed wird durchgereicht) Je nach Parametrierung befindet sich das Ger5t in einem bestimmten Zustand, der eine angepasste Vorgehensweise erfordert. Betriebsart AUTO einstellen. Statuscodierung bei "Qualitat unsicher" Dez Hex Ursache Mallnahme 64 40 Funktionskontrolle Anwarmphase, AUTOCAL, Service vor Ort ... 71 47 Messwert schlecht, letzter gfiltiger Wert Mit SIMATIC PDM Fehler pfazisieren / Gerat tauschen 75 4B Messwert schlecht, Ersatzwert Mit SIMATIC PDM Fehler pfazisieren / Gerfit tauschen 79 4F Nach dem einschalten , Initialwert Messwert verwerfen 80 50 Messwert ausserhalb Bereich Mit SIMATIC PDM Fehler pfazisieren / Umgebungsteperatur zu hoch Statuscodierung bei "QualitAt gut" Dez Hex Ursache Maanahme 128 80 o.k., Nonrnalbetrieb Messwerte verwendbar 132 84 Aktiver Blockalarm, Parameter wurde oe5ndert Verschwindet nach ca. 10 sec 137 89 Warngrenze unterschritten Anwenderprogramm 138 8A Warngrenze uberschritten Anwenderprogramm 141 8D Alarmorenze unterschritten Anwenderprogramm 142 8E Alarmorenze Oberschritten Anwenderprogramm 164 M Wartunosanforderuno Mit SIMATIC PDM Wartunpsanforderuno pedzisieren ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 29 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216600 3.1.4 Discrete Output Block bei ULTRAMAT / OXYMAT / CALOMAT Der Eingangswert des Discrete Output Function Blocks in der Betriebsart AUTO ist der Sollwert, der als zyklisches Nutzdatum zum Auslosen von AUTOCAL Ober den PROFIBUS der Optionsbaugruppe bbergeben wird. Rel. Index Parameter Beschreibung 9 Ubergabewert / Digitalwert in der Betriebsart AUTO 10 Berechneter Ausgangswert des Discrete Output Function Blocks 19 FSAFE_TIME Uberwachungszeit in Sekunden. Die Failsafesteuerun Uberwacht die Buskommunikation, insbesondere der Sollwerte und RCAS IN. 12 Der RUcklesewert enthalt den aktuellen Zustand im Gerat (Istwert) 20 FSAFE_TYPE Definiert die Reaktion des Gerates, wenn nach Ablaut der Uberwachungszeit FSAVE_TIME der verwendete Sollwert noch schlecht ist. Eine aus drei Reaktionen kann eingestellt werden: 0: Der Ersatzwert wird wirksam. 1: Der letzte giiltige Stellwert wird weiterhin ausgegeben. Der Wert hat den Status "Unsicher, letzter gultiger Wert" 21 Ersatzwert im Sicherheitsfall und bei eingestellter Reaktionsart FSAFE_TYPE = 0. 24 SIMULATE Simulationswert und —status fur den Istwert, Freigabe der Simulation. 33 CHECK_BACK nicht benutzt. 34 CHECK_BACK_MASK nicht benutzt. 3.1.5 Nutzdaten Discrete Output Block beim ULTRAMAT / OXYMAT / CALOMAT Es k6nnen folgende Nutzdaten zyklisch Ober den PROFIBUS zum Gerat Obertragen werden. Parametemame Bedeutung Richtung aus Sicht Gasanalysengerat Datentyp Lange in Bytes Setpoint of function block used in Mode AUTO Eingang DS-34 2 Readback of function block Ausgang DS-34 2 Datentyp DS 34: Genaue Beschreibung in PROFIBUS-PA Profile for Process Control Devices/Device Data Sheet Discrete Output Byte 1 Byte 2 DigitalwertiSollwert Status ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 30 EFTA01216601 Bedeutung der Bits in bei ULTRAMATIOXYMAT/CALOMAT ( Autocal auslösen ) MSB LSB B08 B07 B06 B05 B04 B03 B02 B01 Bedeutung -- 1: Autocal abbrechen, wenn in Aktion. B01 kann dann 1 oder 0 sein 1: Autocal auslösen 0: keine Funktion Bedeutung der Bits in Bedeutung bei ULTRAMAT/OXYMAT/CALOMAT ( Quittierung Autocal ) MSB LSB B08 B07 B06 B05 B04 B03 B02 B01 1: Autocal in Funktion 0: Autocal nicht in Funktion Bedeutung des Statusbytes siehe Bedeutung Status ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 31 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216602 3.1.6 Physical Block bei ULTRAMAT / OXYMAT / CALOMAT Im Physicalblock werden mit Parametern gerätespezifisch Eigenschaften angezeigt/eingestellt. Rel. Index Parameter Beschreibung 8 SOFTWARE_REVISION Firmwarestand des Gerätes 9 HARDWARE_REVISION Hardwarestand des Gerätes 10 DEVICE_MAN_ID Herstellercode. SIEMENS AG = 42 11 DEVICE_ID Herstellerbezeichnung: z. B. ULTRAMAT 23 12 DEVICE_SER_Num Seriennummer des Gerätes 13 DIAGNOSIS Bitcodierte vereinheitlichte Diagnosemeldungen 15 DIAGNOSIS_MASK Bitmaske, die angibt, welche DIAGNOSIS-Bits unterstützt werden. 17 DEVICE_CERTIFICATION Angaben über Zertifizierungen im Klartext 18 WRITE_LOCKING Schreibschutzfunktion. Schreibzugriffe werden mit der Fehlercodierung access denied abgewiesen. 19 FACTORY_RESET Kommando, um Rücksetzfunktionen im Gerät auszulösen: • 0: Keine Aktion. • 1: Rücksetzen aller Parameter auf Werkseinstellungen. Mit Ausnahme der eingestellten Stationsadresse, des IDENT_NUMBER-Parameters und der ST REVs. Das Gerät zeigt den folgenden Kaltstart im entsprechenden Bit von DIAGNOSIS für 10 sec an. • 2506: Ausführen eines Warmstarts des Geräts. Das Gerät zeigt den folgenden Kaltstart im entsprechenden Bit von DIAGNOSIS für 10 sec an. • 2712: Rücksetzen der Stationsadresse auf die PROFIBUS — übliche Defaultadresse 126. 20 DESCRIPTOR Möglichkeit zur Hinterlegung einer Beschreibung über das Gerät innerhalb einer Anwendung. 21 DEVICE_MESSAGE Möglichkeit zur Hinterlegung einer Nachricht über das Gerät innerhalb einer Anwendung. 22 DEVICE_INSTAL_DATE Installationsdatum des Gerätes 23 LOCAL_OP_ENA Freigabe der Vor-Ort-Bedienung 24 IDENT_NUMBER Jedes PROFIBUS — Gerät muß eine von der PNO vergebene Identnummer in der Konfigurierungsphase überprüfen. Der Anwender stellt hier ein, welches Konfigurierungsverhalten das Gerät haben soll: • 0: Es wird nur die PROFIL-Identnummer positiv quittiert. • 1: Es wird nur die gerätespezifische Identnummer positiv quittiert. 36 DEVICE_CONFIGURATION Beschreibung der Ausbaustufe des Gerätes ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 32 EFTA01216603 Rel. Index Parameter Beschreibung 37 INIT_STATE Bei einem Reset nimmt das Gerät nach Durchlaufen einer gerätespezifischen lnitialisierungsphase einen parametrierbaren Zustand ein. Als lnitialisierungsphase kann entweder einer der Gerätezustände, oder aber der Zustand vor Reset gewählt werden. • 1: Zustand vor Reset • 2: Run • 3: Standby • 4: Power down • 5: Wartung 38 DEVICE_STATE Es werden vier Zustände definiert, die sich gegenseitig ausschließen: • 2: Run: Alle Betriebsmittel sind aktiv, die notwendig sind, gültige Meßwerte zu erzeugen • 3: Standby: Das Gerät ist meßbereit bzw. kann durch ein Kommando verzögerungsfrei in den Zustand Run übergehen. • 4: Power down: Spar- oder Schonbetrieb. Das Gerät ist nicht meßbereit. Zum Erreichen der Meßbereitschaft kann eine längere Zeit erforderlich sein. • 5: Wartung: Verhalten ist geräteabhängig. Die Wahl eines neuen Zustandes wird durch Schreiben des gewünschten Zustandes (Codes) auf den Parameter DEVICE_STATE durchgeführt. 39 GLOBAL_STATUS Der globale Gerätestatus ist die oberste Hierarchiestufe der Statusinformation. Er zeigt an, ob in einer der unten genannten Statusklassen eine aktive Meldung vorliegt. Jedes Bit des Globalstatus' ist die Oder-Verknüpfung aller Bits der zugehörigen Statusklasse. Bit 0: Ausfall Bit 1: Wartungsbedarf Bit 2: Funktionskontrolle Bit 3: Grenzen (Grenzwertverletzungen erkannt in Transducer und I oder Function Block Bit 4-15: herstellerspezifisch Specifisch für SIEMENS Gasanalysengeräte 50 CALIBRATION_DATA Datum der letzten Kalibrierung. Name der Person/Organisation die kalibriert hat. 51 PRODUCT_CODE MLFB-Nummer 52 ERRORS Störungsmeldungen 53 WARNINGS Wartungsanforderungen Beschreibung auch in PROFIBUS-PA Profile for Process Control Devices /Data Sheet Analyser und General Requirements ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 33 EFTA01216604 Diagnosis Die Diagnosemeldungen können mit Hilfe eines Tools, z. B. SIMATIC HW-Konfig im Menüpunkt "Baugruppenzustand" online sichtbar gemacht werden. Zum Transport von Diagnoseinformationen werden Standardmechanismen des PROFIBUS-DP herangezogen und dem Klasse 1 Master aktiv gemeldet. Als Diagnoseinformation steht dem Master dann der DIAGNOSIS-Parameter aus dem Physical Block zur Verfügung. Die Gerätestati werden auf die PROFIBUS- PA Physical Block.DIAGNOSIS — Bits abgebildet. Die Diagnosemeldungen können mit Hilfe eines Tools, z. B. SIMATIC HW-Konfig im Baugruppenzustand online sichtbar gemacht werden. Ebenso ist es möglich mit Hilfe von SIMATIC PDM den DIAGNOSIS- Parameter auszulesen. Eine detaillierte Liste ist Anhang Kapitel 7.4 Diagnosis zu finden. 3.1.7 Spezifische Parameter im Physical Block Spezifische Parameter im Physical Block für SIEMENS Gasanalysengeräte Type Number 50 CALIBRATION_DATA record 2 Date octet string 8 Who visible string 24 51 PRODUCT_CODE visible string 32 52 ERRORS octet string 4 53 WARNINGS octet string 2 ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 231 OXYMAT 61 34 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216605 Störungen sind im Parameter ERRORS bei ULTRAMAT / OXYMAT / CALOMAT wie folgt codiert: Bedeutung von S1 ...532 siehe Kapitel 7.4 Diagnosis . Byte 0 Bit 8 7 6 5 4 3 2 1 Störung S8 S7 S6 S5 S4 S3 S2 S1 Byte 1 Bit 8 7 6 5 4 3 2 1 Störung S16 S15 S14 S13 S12 S11 S10 S9 Byte 2 Bit 8 7 6 5 4 3 2 1 Störung S24 S23 S22 S21 S20 S19 S18 S17 Byte 3 Bit 8 7 6 5 4 3 2 1 Störung S32 S31 S30 S29 S28 S27 S26 S25 Wartungsanforderungen sind im Parameter WARNINGS bei ULTRAMAT / OXYMAT / CALOMAT wie folgt codiert: Bedeutung von W1 ...516 siehe Kapitel 7.4 Diagnosis. Byte 0 Bit 8 7 6 5 4 3 2 1 Wart.anf. W8 W7 W6 W5 W4 W3 W2 W1 B te 1 Bit 8 7 6 5 4 3 2 1 Wart.anf. W16 W15 W14 W13 W12 W11 W10 W9 ULTRAMAT 6 I OXYMAT 6 / CALMAT 6 / ULTRAMAT 23 OXYMAT 61 35 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216606 4 Inbetriebnahme Funktionen/Bedienung über PROFIBUS-PA Nach der Montage und der Buskonfiguration, der Einstellung der Stationsadresse (siehe Kapitel 5 Bedienung) kann das System mit den entsprechenden Hilfsmitteln konfiguriert werden. Bei einer Nachrüstung ist auf den aktuellen Firmwarestand der Geräte zu achten (siehe: Kapitel 6.2 Firmware). Für die Bedienung über PROFIBUS-PA ist die Verwendung einer PC-Software wie SIMATIC PDM notwendig. Die Bedienung ist in den dazugehörigen Bedienungsanleitungen und Online-Hilfen beschrieben und muss dort eingesehen werden. Über die PROFIBUS-PA-Kommunikation ist zur Zeit nur ein eingeschränkter Funktionsumfang für die Gasanalysegeräte ULTRAMAT / OXYMAT / CALOMAT erreichbar. 4.1 Auswahl von Geräten mit Konfigurierwerkzeug Am Beispiel STEP 7, HW-Konfig soll die Auswahl der Gasanalysengeräte ULTRAMAT / OXYMAT / CALOMAT erläutert werden. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 231 OXYMAT 61 36 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216607 4.1.1 Auswahl Sollkonfiguration IA Sista Raten En1/49. >tem. 8necto fahr Eteee dee Rble I Wel _rer. PROFIBUS CP ihm P0008002, OPMarla j131,*(107 it411,4 19 IIITP UU f :3 I .5 ULI 21 rt ODeemYal. Amme.' em. I ill är3lUCA131 MFaifdl 171MOU ••• PP000.100 F.4450,-000,09801 00 XX 101 Uli 9,01010t 13407,406 BeHt•un00 Kathnto Etee I ne Ateene Kaevedrit P540710. 6E S7 4071041:00M0 A.. OPU 4142 OP 6ES7 41G-DM02,0.60 3 OrAtteW /C{C," arte` ., /teer -I Erten Molch .212J• Pole I94,101 FACP Oen 00 PACF F0 J anaß, • J (-”edi0:000 •J r (.00n, S, • -J Zita • —I Duoh•-6 • _j %Jay Hume. • _J - _j .1.0.04:enr Se PROFIS tl P44eie ion . i (lt*. SO€ - J 51ENESS - C».mi 6 3 - IJ,001.0•00.. -i Lhey.6 3 Unnnelrexti leressu Sone,* SIRATIC X0 SatATC CO 9HATIC PC Band (cm' 30N10 • a 9RAIC PC Laxe fr abeels01 t/1710, iaGeur 23 Die betreffenden Geräte verfügen entweder über eine DP- oder eine PA-Schnittstelle. Das passende Gerät wählen Sie aus dem DP- oder PA-Katalog aus. ULTRAMAT 6 I OXYMAT 61 CALOMAT 6 I ULTRAMAT 231 OXYMAT 61 37 Schnittstelle PROFIBUS DP / PA Interface A5E00054148.03 EFTA01216608 4.1.2 PROFIBUS-Adresse XIMEZIE= YRIRA bee*. LRACRA >Wien 0•a(M Esas tea Me Disime I9uI g gel WS alro 3'Je PROFIEUSII OPMoto LACFEV'a2 DPW.. AN«, Pee,da ri t üben.untiree...44 ••• 45 45 IT MOW. Laperateidi ieetreher. Us? 4169«.021I480 edik FF0‘1:7J5C‚. 14.3.311‚:•151-u . _j :In If 4 A.II,J)In:1 • _I 1e IX.M • _j trvs • J Duchte. • J na.cettee#1 • J ‚Parse - J 4>Reneenelik PAM • i PPP 3 • JS.f J 9tere - (erd 6 11-synahadI mama Ilnexxiele004 . i uttane, R 11-synahadI . J Tenpi ., • J Sevenx • 3 ',PAMIR XO SIMMIC 4.1) • • SIANTICPC ReSCRaxel)XVIO SMATIC se», AAde net*, seek Iv Geaselowerf et Iphmat 13 Hier stellen Sie die PROFIBUS Adresse ein. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 38 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216609 4.1.3 Funktionsblöcke A lime letteem Loa , Z•ebeeee tetee Etg[e. Le"' 21. ()ISMS lid lil %lei 2ro J L'I S sui {{Un6Usl DPAtees PR itiod IS? am Is, PROP VA.. .7-, 114321 T T T *e lG iirsiutkisi * I %I . I PariustsPTIO etTPIAll tie if LCAll ill) 411 il 1}AUl * • L_P 24 1 MI (LelfAIIIMAIHat PA SWIM: I Q 8445400/OP44~0 IO fa Belielainot 'Cadet. A /lame lemmas etT, 15? krewascuoLe (/nknahall !Kf Aa 572 51) Pei stie[heä PROMIUTPA - Akb'en ChenlAtagina • Li 05mm -.I Senate One Recite 2.1 Flamed wee Para, - Gereweeemeee RM. 3 Se _J 9t14/15 - CrynY u•••••••ehedI k awe» Uamael u bane e lieewseleedI Unease • _I I•yee, e eemTIC 300 SPAITIC403 [e • SPANTICPCIlimdCeehe 3COM sbaticitseno. lel Is! frL1 Seve«e INN G.:go-414er. , 155.541Z3 Hier können Sie die Anzahl der Blöcke und die Adressverteilung kontrollieren. ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 39 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216610 4.1.4 SIMATIC PDM Gerätekatalog 540,‘ ISS•CeSS Dee.% &DMA% Asecet SAN ESA litt Dielte ieg g sie o lo g RA> g A 4: CPU 41G CP 413514 cP 401 PS-Seenneeeneb; lsIonseOGosO PFOODUSO OP •n 0 PROF£U OPNA• imein) it Sl im IS I R4411 231A 02 tLIARMI 232R UVRAUT 232802 ULTRAMAI Z3 3 ULTRUMI 23 38 02 - U•ern ULTRemil6 R ULIAWAIS2A ARPAPIDOs ULIPMAI 23Gannelnerpen nl Iffien. Ansenene oneln • SU iuei 1:2w Wel 71 in T xiiin ■ OMI 1 man *ehe RAN • IXs•- ..12.111 1 bit Henne PROREUSOP PROFIEUSI3/4 • :j mos, • :J Oen. ospeg • J °Simons :3 Smene • :I See* • —I SVO** - .J neesdose* • _s Krstl . 1 %JOS _J SIEMENS r rescalnedel CAAA Ci ismer+ • :3 Ssmoos SnesTIC XO ,B SMOK Bd0 • ■ SMOKSO Isbeltroxi310/40 e SeestiCPCSessee I 2J ~Se Os Nach Doppelklick auf die neue Geräte-Ikone können Sie das passende Gerät auswählen. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 40 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216611 4.1.5 SIMATIC PDM starten SINLA I it: lUM IISIR Stell. MGM Qa. fin/ Angeht East Hie te,t,,ter P : I Ads.ases: grautnen wein tue 1 12. elefialennign latAnnialgnna nageren.elnern nuleßeansben nrcoge %rd Bencnotede utmei..szLiaaren S Perumaler Wert Einheil Status Siemens Anelycer • klentlfikatine • • Setfieleselnheil TAG IrISRSItite Initialwert Initialwert Betthebere Anelyzet Hechnchl Massage • . Gers Stauche Rev.P4r Hersteller Produktname Gentekonfigutation Bastelfrommer Seneemunweet Seflware-Renzion Henteareaawion Proil.Rimiann 130 0 Siemens Siemens Merze Initialweh Initialwert InnIelwerl Inhlahven Initlahven Initialwert Initialweit InMalwen Innlalwen Initlalwen Initialwert initiehverl Inhiaheen InMahven Option PROF.3113 7M82 113 COI 0, 0 PROFIBUS Werd Penbet AllerstelleSpeirtich Enenimm 01 01 2000 heielterungezurstencl Zusland rot Betet 01 01 2IXID Letzter Abgletch Beznaeor Name • Eingang • • Ilesserome 1 SI Pe.. •Ur ms eirau <nun Inhlalwen Innlakeen Initialwen Innlalwerl Inillahven Initialwen Usrne Abt SSlifit,9,-sll ArttruS•wert Enewert Componem 1 'real 0 103 • Ausgang • • Analog Input Function Block 1 Statische Rar - 1r Einhs InillaNterl Initialwen DnichanSiell.taHleanduken S zsabsI sereVestrem NUN Nach der Auswahl können Sie SIMATIC PDM starten. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 41 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216612 4.2 Einstellungen ULTRAMAT, OXYMAT und CALOMAT bewältigen eine Vielzahl von Messaufgaben. Dazu müssen Sie nur die folgenden Einstellungen vornehmen: Einstellungen mit SIMATIC PDM: Hier stellen Sie die Parameter ein, die auch die zyklischen Nutzdaten beeinflussen. Wenn Sie das passende Gerät entspechend des Typs und der Anzahl von Komponenten auswählen, erhalten Sie in der SIMATIC PDM-Oberfläche entsprechend voreingestellte Parameter. Die folgenden Abschnitte führen nur jene an, die Sie zusätzlich einstellen müssen. 4.2.1 Auswahl Gasanalysengeräte / Transducerblock Messgröße Legen Sie ein passendes Gerät an. Im Block Messgröße kann der Messbereich nicht verändert werden. Hier wird immer der maximale Messbereich dargestellt. Bei manchen Analysengeräten kann die Einheit zwischen vpm und mg/m3 umgeschaltet werden. Der Funktionsblock 'Analog Input Block' übernimmt den benötigten Eingangsbereich vom Transducerblock 'Messgröße'. Der Ausgangsbereich muss entsprechend den Anforderungen im Analog Input Block parametriert werden. Der Name der Komponente kann im Transducerblock geändert werden und wird im Messwertanzeigebild in der Lasche Messwerte/Eingang benutzt. Mit dem Abtasintervall kann die Häufigkeit der Messwerterneuerung eingestellt werden. 4.2.2 Analog Input Block / TAG Der Name der Prozessmessgrösse kann als „TAG" geändert werden. Im Messwertanzeigebild in der Lasche Messwerte/Ausgang wird dieser Name zur Identifikation des Messwertes angezeigt. 4.2.3 Autocal Die Analysengeräte können, wenn die entsprechende Option vorhanden ist, einen kompletten Kalibrierzyklus durchführen. Im Menü Gerät/Autocal kann diese Kalibrierung gestartet werden. ULTRAMAT 61 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 1 OXYMAT 61 42 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148.03 EFTA01216613 4.2.4 Anpassung auf die gewünschte Prozessgröße Der Funktionsblock 'Analog Input' hat die Aufgabe, den Messwert auf den Prozesswert abzubilden. In der Regel wollen Sie den Messwert direkt auf den Bus schalten. In diesem Fall werden Eingangs- und Ausgangsbereich vom Arbeitsbereich übernommen. Die gemessene Konzentration kann hier an die Prozessgröße angepasst werden. Übertragen Sie Anfangs- und Endwert des Eingangsbereichs in den Anfangs- und Endwert des entsprechenden Ausgangsbereichs, wie in den folgenden Beispielen beschrieben: ur Hinweis: Im Funktionsblock Analog Input erfolgt kein Zugriff auf das Gerät über PROFIBUS-PA. Der Eingangswert kann hier lediglich mit Hilfe von SIMATIC PDM ausgewertet werden. Beispiel: Sie möchten den Eingangsbereich 0 bis 1000 mg/m3 CO dem Ausgangsbereich 0 bis 100 % zuordnen. Hierzu gehen Sie wie folgt vor: Stellen Sie folgende Parameter ein: im Block 'Messgröße 1': CO als Messkomponente sowie als Einheit der Primärvariable: mg/m3 im Funktionsblock 'Analog Input 1': als Eingangsanfangswert: 0 als Eingangsendwert: 1000 als Einheit (Ausgang): % als Ausgangsanfangswert: als Ausgangsendwert 100,0 0,0 4.2.5 Elektrische Dämpfung Die elektrische Dämpfung wirkt wie ein Filter erster Ordnung. Nach der von Ihnen voreingestellten Filterzeitkonstante T63 hat der Ausgang 63 % des Eingangswertes erreicht. Stellen Sie im Funktionsblock des Analogeingangs als Parameter Filterzeitkonstante die gewünschte Zeit (im Bereich von 0 bis 100 s) ein. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 231 OXYMAT 61 43 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216614 4.2.6 Warn- und Alarmgrenzen Die Funktionsblöcke des Analogeingangs haben obere und untere Warn- und Alarmgrenzen für den Ausgang. Um eine instabile Anzeige der Warnungen und Alarme zu vermeiden, können Sie eine Hysterese angeben. In den Funktionsblöcken des Analogeingangs stellen Sie folgende Parameter nach den Prozessbedingungen ein: • Grenzwert-Hysterese • Warngrenze oben • Alarmgrenze oben • Warngrenze unten • Alarmgrenze unten Beim Überschreiten der Grenzen wird die Ausgabe von einem Statuswert begleitet, den Sie in Ihrem Anwenderprogramm auswerten können. Eine Übersicht über die einzelnen Grenzwerte können Sie dem folgenden Bild entnehmen. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 1 OXYMAT 61 44 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216615 4.2.7 Ausfallverhalten Die Funktionsblöcke des Analogeingangs können bei Ausfall des Messblocks ein von Ihnen vorgegebenes Verhalten aufnehmen. Werden die Ausgangsvariablen des Messblocks auf Grund eines Fehlers von einem Status "Schlecht" begleitet, z. B. "Schlecht - Sensorfehler", aktivieren die Funktionsblöcke das Ausfallverhalten. Der Ausgang wird dann von einem "unsicheren" Status begleitet. Eine Übersicht der Statki finden Sie in Abschnitt 3.1.3. Stellen Sie im Funktionsblock Analogeingang das Ausfallverhalten ein. Ausfallverhalten Beschreibung Der Ersatzwert wird in den Ausgangswert übernommen Der vordefinierte Sicherheits-Vorgabewert wird ausgegeben Speichern des letzten gültigen Ausgangswertes Der letzte gültige Ausgangswert wird ausgegeben Am Ausgang liegt der falsch berechnete Messwert an (Ausfalllogik abgeschaltet) Der schlechte Ausgangswert wird von dem Status begleitet. den der Messblock ihm zuteilte 4.2.8 Simulationen Simulationsfunktionen helfen Ihnen bei der Inbetriebnahme von Anlagenteilen und Analysegeräten. Hierbei können Sie Prozesswerte ohne die Erfassung realer Messwerte erzeugen. Der Wertebereich der simulierten Prozesswerte läßt sich voll ausschöpfen: So ist auch die Simulation von Fehlern möglich. 4.2.8.1 Simulation des Ausgangs Mit der Simulation des Ausgangs können Sie am Ausgang des ULTRAMAT/OXYMAT/CALOMAT über azyklische Schreibzugriffe Prozesswerte für den zyklischen Nutzdatenverkehr bereitstellen. So können Sie die Prozesswertverarbeitung im Automatisierungsprogramm überprüfen. Hierzu gehen Sie wie folgt vor: wählen Sie die Simulation des Ausgangs aus stellen Sie den Zielmodus auf MAN (manuell) tragen Sie den gewünschten Ausgangswert, die Qualität und den Status ein übertragen Sie die Einstellungen vom Programm in den Messumformer. Das Verhalten des Ausgangs können Sie z. B. in SIMATIC PDM oder über eine Variablentabelle (VAT-Baustein) beobachten. Um danach in den Normalbetrieb zurückzukehren, müssen Sie den Zielmodus auf AUTO umstellen. ULTRAMAT 6 I OXYMAT 61 CALOMAT 61 ULTRAMAT 23 I OXYMAT 61 45 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216616 4.2.8.2 Simulation des Eingangs Mit der Simulation des Eingangs können Sie die Anpassung des Messwerts auf die gewünschte Prozessgröße, die Überwachung auf ihre vorgegebenen Prozessgrenzen, die elektrische Dämpfung und das Ausfallverhalten überprüfen. Hierzu führen Sie folgende Schritte durch: • wählen Sie die Simulation des Eingangs aus • stellen Sie den Zielmodus auf AUTO • wählen Sie den Simulationsmodus "freigegeben" • tragen Sie den gewünschten Eingangswert, die Qualität und den Status ein • übertragen Sie die Einstellungen vom Programm in den Messumformer. Das Verhalten des Ausgangs können Sie z. B. in SIMATIC PDM beobachten. Um danach in den Normalbetrieb zurückzukehren, müssen Sie die Simulation ausschalten. 4.2.9 Status- und Fehlermeldungen Die Anbindung von ULTRAMAT / OXYMAT / CALOMAT über eine PC-Software wie SIMATIC PDM ermöglicht eine Fehlerdiagnose. Aktuelle Fehler und Wartungsanforderungen können mit SIMATIC PDM, im Menü 'Ansicht, Gerätezustand', ausgewertet werden. Diese Meldungen werden im Klartext dargestellt, wodurch entsprechende Maßnahmen zur Störungsbeseitigung erleichtert werden. 4.2.10 Rücksetzen 4.2.10.1 Rücksetzen in den Auslieferungsstand Sollte der ULTRAMAT / OXYMAT / CALOMAT so verstellt sein, dass er seine Messaufgabe nicht mehr erfüllen kann, können Sie mit dieser Funktion den Auslieferungszustand wieder herstellen. Mit dieser Funktion werden alle Parameter auf die Werkseinstellungen zurückgesetzt. Das Rücksetzen wird von der Diagnosemeldung 'Kaltstart wurde ausgeführt" angezeigt. Solange noch kein Messwertergebnis zur Verfügung steht, wird der Status "Unsicher, Initialwert, Wert konstant" ausgegeben. 4.2.10.2 Rücksetzen der PROFIBUS—Adresse auf 126 Hat kein anderes Gerät in Ihrem System die voreingestellte Adresse 126, können Sie den PROFIBUS-Strang im laufenden Betrieb des Automatisierungs- bzw. Leitsystems um Ihren ULTRAMAT/OXYMAT/CALOMAT erweitern. Anschließend müssen Sie die Adresse des neu eingebundenen Geräts auf einen anderen Wert ändern. Wenn Sie einen ULTRAMAT/OXYMAT/CALOMAT aus dem PROFIBUS-Strang entfernen, sollten Sie seine Adresse über diese Funktion auf 126 zurücksetzen, damit Sie ihn bei Bedarf in dieses oder ein anderes System wieder einbinden können. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 OXYMAT 61 46 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216617 5 Bedienung 5.1 Einstellen der Stationsadresse ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / OXYMAT 61 Hinweis Die Grundprinzipien der Bedienung sind in den Gerätehandbüchern ULTRAMAT 6 / OXYMAT 6 / CALOMAT 61 OXYMAT 61 jeweils in Kapitel 5 erläutert. Die Stationsadresse kann im Hauptmenue unter Konfiguration eingestellt werden. Hierzu ist der Code der Stufe 2 erforderlich. A 90 PROFIBUS-Konfig. CO2 Adresse 126 Mit dieser Funktion lässt sich die PROFIBUS Stationsadresse einstellen. Die Adresse ist von 0...126 einstellbar. Warnung Durch die Veränderung der Stationsadresse kann die Kommunikation am Bus beeinflußt werden. ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 47 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216618 5.2 Einstellen der Stationsadresse ULTRAMAT 23 Hinweis Die Grundprinzipien der Bedienung sind im Gerätehandbuch ULTRAMAT 23 in Kapitel 5 erläutert. Die Stationsadresse kann im Hauptmenue unter Konfiguration im Untermenuepunkt Spezial-Funktionen eingestellt werden. Hierzu ist der Code der Ebene 2 erforderlich. A Codes/Sprache AUTOCAL-Abweichung ELAN/PROFIBUS Werksdaten/Res./Einh. ELAN Parameter ELAN ext.Quereinfl. PROFIBUS Parameter PROFIBUS Adresse : 126 In diesem Menue den Unterpunkt ELAN/PROFIBUS anwählen Weitere Auswahl Unterpunkt PROFIBUS Parameter In diesem Dialog lässt sich die PROFIBUS Stationsadresse einstellen. Die Adresse ist von 0...126 einstellbar. Warnung Durch die Veränderung der Stationsadresse kann die Kommunikation am Bus beeinflußt werden. ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 48 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216619 6 Wartung Die Optionsbaugruppen sind wartungsfrei. 6.1 Rücklieferung Bei einer Reparatur muß die Baugruppe an SIEMENS SPA CSC 1,chemin de la Sandlach F-67506 Haguenau eingeschickt werden. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 OXYMAT 61 49 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216620 6.2 Firmware Ist es auf Grund von Verbesserungen notwendig die Firmware der PROFIBUS-Kommunikation zu tauschen, muß das Flash - EEPROM auf der Optionsbaugruppe ( gesockelter Baustein) ersetzt werden. Für den Betrieb im CALOMAT 6 dürfen nur EEPROMS ab einem Firmware-Stand von 1.3.0 verwendet werden. Die Firmware ist unter der Sachnummer A5E00057164 als Ersatzteil im CSC Haguenau bestellbar. -> Kapitel 6.1 SIEMENS SPA 6.2.1 Firmware ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23, OXYMAT 61 Beim Nachrüsten mit der PROFIBUS-Option wird unter Umständen ein Update erforderlich: ULTRAMAT 6 (vor SW-Version 4.2) Deutsch Englisch Französisch Spanisch Italienisch OXYMAT 6 und OXYMAT 61 Deutsch Englisch Französisch Spanisch Italienisch CALOMAT 6 Deutsch Englisch Französisch Spanisch Italienisch C79451-A3478-5501 C79451-A3478-5502 C79451-A3478-5503 C79451-A3478-5504 C79451-A3478-5505 (vor SW-Version 4.2) C79451-A3480-5501 C79451-A3480-5502 C79451-A3480-5503 C79451-A3480-5504 C79451-A3480-5505 (vor SW-Version 1.1.0) A5E00092676 A5E00092677 A5E00092678 A5E00092679 A5E00092680 ULTRAMAT 23 (vor SW-Version 2.6) alle Sprachen C79451-A3494-5501 ULTRAMAT 6 f OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 50 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148.03 EFTA01216621 7. Anhang 7.1 Bedienung mit SIMATIC PDM Mit Hilfe des Bedienprogramms SIMTIC PDM und einem Personalcomputer (PC) bzw. Programmiergerät (PG) kann eine Parametrierung und Beobachtung von Messwerten durchgeführt werden. Detaillierte Informationen finden Sie im Internet unter http://www.feldgeraete.de/00/produkte/simatic pdmlinfos.html 7.2 GSD Gerätestammdatei Für den zyklischen Datenaustausch sind Dateien für PROFIBUS DP / PA notwendig, die im Internet unter Deutsch: Englisch: http://www.ad.siemens.de/csikisd http://www.ad.siemens.de/csi e/gsd geladen werden können. siem809c.gsd (3 KB) PA sprachunabhängig siem809eAsd (4 KB) DP sprachunabhängig sie809cn.bmp (3 KB) Bitmap_Device 7.3 Technische Daten PROFIBUS PA (nach DIN IEC 1158-2) Busspannung 9 bis 32 V (nicht Exi) 9bis 24 V bei Exi 10 mA (typisch) 31,25 kBit/s PROFIBUS gegen übrige Elektronik/Gehäusemasse: 1810VAC Stromaufnahme Baudrate Galvanische Trennung PROFIBUS DP (nach EN 50170) Baudraten Galvanische Trennung PROFIBUS DP / PROFIBUS PA C2-Verbindungen 9.6, 19.2, 93.75, 187.5, 500 kBit/s, 1.5, 3, 6,12 MBit/s PROFIBUS gegen übrige Elektronik/Gehäusemasse: 50V= Es werden 4 Verbindungen zum Master Klasse 2 unterstützt. Automatischer Verbiundungsabbau 60 s nach Kommunikationsunterbrechnung ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 51 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216622 7.4. Diagnoseinformation Aus den folgenden Tabellen kann die Zuordnung von Störungsmeldungen/Wartungsanforderungen der Geräte zu den Diagnosebits im Physical Block entnommen werden. 7.4.1 Diagnoseinformation ULTFtANIAT 6 Störung (S) Wartungsanf. (W) Nr. Störung / Wartungsanforderung Bedeutung Diagnose Byte / Bit Diagnosebit Name S1 Parameterspeicher 1 / 4 2 / 2 DIA_MEM_CHKSUM DIA_CONF INVAL DIA_HW_MECH S2 Choppermotor gestört 1/1 S3 Mikroströmungsfühter 1 / 1 1/5 DIA_HW_MECH DIA MEASUREMENT S4 Externe Störung 1 / 1 DIA HW MECH S5 Temp. Empf.Kammer 1 / 1 DIA HW MECH S6 Heizung Feldgerät defekt 1 / 0 DIA HW ELECTR S8 Signal Druckaufnehmer 2 / 1 DIA SUPPLY S11 Vergleichsgasdruck. zu gering 2 / 1 DIA SUPPLY S12 Spannungsversorgung 2 / 1 DIA SUPPLY S14 Meßwert > Kennlinienendwert 1 / 1 1 / 5 DIA HW MECH DIA MEASUREMENT S15 Justierung abgebrochen 1 /5 DIA MEASUREMENT S16 Meß asdurchfluß zu gering 2 /1 DIA SUPPLY W1 Justierunterschied zu groß 2 / 5 DIA MAINTENANCE W2 Nullpunkt Stellreserve < 20% 2 / 0 2 / 5 DIA ZERO ERR DIA MAINTENANCE W3 Signalspg. Abgleich zu klein 2 / 5 DIA_MAINTENANCE W4 Uhr stellen 2 / 5 DIA_MAINTENANCE W5 Mikroströhmungsfühler 2 / 5 DIA_MAINTENANCE W6 Temperatursensor LCD-Display 1 / 3 2 / 5 DIA_TEMP_ELECTR DIA MAINTENANCE W7 Temperatur Empfängerkammer > 70°C 2 / 5 DIA_MAINTENANCE W9 Externe Wartungsanforderung 2 / 5 DIA MAINTENANCE W10 Autocal Check Abweichung 2 /5 DIA MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 52 Schnittstelle PROFIBUS DP / PA Interface ME00064148-03 EFTA01216623 7.4.2 Diagnoseinformation CALOMAT 6 Störung (S) Wartungsanf. (W) Nr. Störung / Wartungsanforderung Bedeutung Diagnose Byte / Bit Diagnosebit Name S1 Parameterspeicher 1 /4 2 / 2 DIA_MEM_CHKSUM DIA CONF INVAL S4 Externe Störung 1 / 1 DIA HW MECH S5 Temp. TCD 1 / 1 DIA HW MECH S12 Spannungsversorgung 2 / 1 DIA SUPPLY S14 Meßwert > Kennlinienendwert 1 / 1 1 / 5 DIA HW MECH DIA MEASUREMENT S15 Justierung abgebrochen 1 /5 DIA MEASUREMENT W1 Justierunterschied zu groß 2/ 5 DIA MAINTENANCE W4 Uhr stellen 2 / 5 DIA MAINTENANCE W6 Temperatursensor LCD-Display 1 / 3 2 / 5 DIA TEMP ELECTR DIA:MAIN-FENANCE W9 Externe Wartungsanforderung 2 / 5 DIA_MAINTENANCE W10 Autocal Check Abweichung 2 / 5 DIA_MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 53 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216624 7.4.3 Diagnoseinformation OXYMAT 6 und OXYMAT 61 Störung (S) Wartungsanf. (W) Nr. Störung / Wartungsanforderung Bedeutung Diagnose Byte / Bit Diagnosebit Name S1 Parameterspeicher 1 /4 2 / 2 DIA MEM CHKSUM DIA- CONV INVAL S2 Choppermotor gestört 1 / 1 DIA HW MECH S3 Mikroströmungsfühler 1 / 1 1 / 5 DIA HW MECH DIA MEASUREMENT S4 Externe Störung 1 / 1 DIA HW MECH S5 Temp. Empf.Kammer 1 / 1 DIA HW MECH S6 Heizung Feldgerät defekt 1 / 0 DIA_HW_ELECTR S7 Temperatur Meßkopf außer Toleranz 1 / 1 DIA_HW_MECH S8 Signal Druckaufnehmer 2 /1 DIA_SUPPLY S9 Signal zu groß 1 /5 DIA_MEASUREMENT S11 S12 Vergleichsgasdruck zu ei. .__ g, hg I Spannungsversorgung 2 / 1 DIA_SUPPLY DIA_SUPPLY S14 Meßwert > Kennlinienendwert 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S15 Justierung abgebrochen 1 /5 DIA MEASUREMENT S16 Meßgasdurchfluß zu gering 2 /1 DIA SUPPLY W1 Justiertoleranz überschritten 2 / 5 DIA MAINTENANCE W2 Signalspannung Nullpunkt zu groß 2 /0 2 / 5 DIA ZERO ERR DIA MAINTENANCE W3 Signalspg. Empfindlichkeit zu groß 2 / 5 DIA MAINTENANCE W4 Uhr stellen 2 / 5 DIA MAINTENANCE W5 Mikrostromungsfuhler 2 / 5 DIA MAINTENANCE W6 Temperatursensor LCD-Display 1 / 3 2 / 5 DIA_TEMP_ELECTR DIA_MAINTENANCE W7 Temperatur Analysierteil > 70 °C 2 / 5 DIA_MAINTENANCE W8 Temperatur Meßkopf außerh. +- 3°C 2 / 5 DIA_MAINTENANCE W9 Externe Wartungsanforderung 2 / 5 DIA_MAINTENANCE W10 Autocal Check Abweichung 2 / 5 DIA_MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 54 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216625 7.4.4 Diagnoseinformation ULTRAMAT 23 Stoning (S) Wartungsanf. (W) Nr. Stoning / Wartungsanforderung Bedeutung Diagnose Byte / Bit Diagnosebit Name S1 Messwert Kanal 1 auger Toleranz 1 / 5 DIA_MEASUREMENT S2 Messwert Kanal 2 auger Toleranz 1 / 5 DIA_MEASUREMENT S3 Messwert Kanal 3 auger Toleranz 1 / 5 DIA_MEASUREMENT S4 Messwert O2 auger Toleranz 1 / 5 DIA_MEASUREMENT S5 Netzspannung auger Toleranz 2 / 1 DIA_SUPPLY S6 Ger5tetemperatur auger Toleranz 1 / 1 DIA_HW_MECH S7 Luftdruck auger Toleranz 2 / 1 DIA_SUPPLY S8 Keine Stromung wahrend messen 2 / 1 DIA_SUPPLY S9 Kein Temperaturabgleich durchgefahrt 1 / 7 DIA _INIT_ERR SW Keine Stramung bei AUTOCAL 2 / 1 DIA SUPPLY S11 Messwert O2 zu klein 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S12 Analogstromausgabe fehlerhaft 1 /0 DIA HW ELECTR S13 Summenfehler aller IR Kan5le 1 / 1 1 / 5 DIA_HW_MECH DIA_MEASUREMENT S14 Kanalbesttickungsfehler 1 / 1 DIA_HW_MECH S15 AUTOCAL-Drift zu grog 2 / 0 DIA_ZERO_ERR S16 Eeprom-Fehler 1 /4 2 / 2 DIA_MEM_CHKSUM DIA CONF INVAL S17 Phase nicht gefunden 1 / 1 DIA HW MECH S18 Serielle Schnittstelle fehlerhaft 1 /0 DIA HW ELECTR S19 S20 Kanal 1 nicht justiert 1 /7 DIA INIT ERR S21 Kanal 2 nicht justiert 1 /7 DIA INIT ERR S22 Kanal 3 nicht justiert 1 /7 DIA INIT ERR S23 Strahlerspannung auger Toleranz 1 /0 DIA HW ELECTR S24 Bffickenspeisespannung auger Toleranz 1 / 0 DIA_HW_ELECTR S25 Bruckenhalbspannung auger Toleranz 1/0 DIA HW ELECTR S26 Lockin-Fehler 1 /0 DIA HW ELECTR S27 Exteme Sterung 1 / 1 DIA HW MECH S28 S29 S30 S31 Empf. des O2-Sensors zu qering 1 / 1 DIA HW MECH S32 Extemer ADU-Fehler 1 /0 DIA HW ELECTR W1 AUTOCAL-Drift zu grog 2 / 5 DIA MAINTENANCE W2 O2-Sensor 2 / 5 DIA MAINTENANCE W3 LCD-Temperatur auger Toleranz 1 / 3 2 / 5 DIA_TEMP_ELECTR DIA_MAINTENANCE W4 Externe Wartungsanforderung 2 / 5 DIA_MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 55 EFTA01216626 7.5. Objekttabellen 7.5.1 Device Managment Device Managment il Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbescnrethung Data Type Num Per Store (acc. to profile) cy di c re ad wit to MAND 1 0 HEADER unsigned16 6 C x 1 04000 Dir ID Directory ID (reserved) 2 0x0001 Num Dir Rev Directory Revision Number 3 0x0001 Num Dir Obj Number of Directory Objects (Diectories) 4 0x0000 Num Dir Entries Total Number of Directory Entries 5 0x0001 First Comp Dir Entry Entry number of first Composite List Dir Entry 6 0x0003 Num Comp OW Entry Number of Composite List Directory Entries MAND 1 1 COMPOSITE_LIST_DIRECTORY_ ENTRY unsigned16 8 C x 1 0x0104 Start PB Ref Directory Index for Physical Block 2 1 Num PB Number of Physical Blocks 3 0x0205 Start TB Ref Directory Index for first Transducer Block 4 4 Num TB Number of Transducer Blocks S 0x0309 Stan FB Ref Directory Index for first Function Blcck 6 5 Num FB Number of Function Blocks 7 0x016E Slot Index PB Physical Block: slot 1. index absolute 110 8 ra Nun PB Peram Number of parameters MAND 1 2 COMPOSITE_LLST_DIRECTCRY_ ENTRY unsigned16 8 C x 1 0x0142 Slot Index TI31 Transducer Block 1: slot 1. index absolute 66 2 roc Num TB1 Pam Number of parameters 3 0x0242 Slot Index T82 Transducer Block 2: slot 2 index absolute 66 4 Ecx Num TB2 Pam Number of parameters S 0x0342 Slot Index T83 Transducer Block 3: slot 3 index absolute 66 6 Ecx Num TB3 Pam Number of parameters 7 0x0442 Slot Index TB4 Transducer Block 4: slot 4. index absolute 66 8 roc Num TB4 Pam Number of parameters MAND 1 3 COMPOSITE_LIST_DIRECTORY_ ENTRY unsIgned16 10 C x 1 0x0110 Slot Index FB1 Function Block 1: slot 1. index absolute 16 2 Ea Num FBt Pam Number of parameters 3 0x0210 Slot Index FB2 Function Block 2: slot 2. index absolute 16 4 ',cc Num FB2 Pam Number of parameters S 0x0310 Slot Index FB3 Function Block 3: slot 3. index absolute 16 6 ra Num FB3 Pam Number of parameters 7 0x0410 Slot Index FB4 Function Block 4: slot 4. index absolute 16 8 Ea Num FB4 Pam Number of parameters 9 0x0510 Slot Index FB5 Function Block 5: slot 5 index absolute 18 10 ',cc Nun FBS Pam Number of parameters EFTA01216627 7.5.2 Function Block Al 1 Function Block Al 1 (Analog Input) Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbeschreibung Data Type Worn ber Store (as. to profile) cy di c re ad arts le BLOCK 1 16 0 BLOCK OBJECT Block-Charadelistic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Typ (Function) 3 1 Parent Class Obergeordnete lasses: 01 = Input 4 1 Class IGasse: 01 = Analog Input 5 0 DO-Reference resented 8 0 DD-Revision resented 7 0x4002 Profile PA-Profil-Nummer lurch PNO vergeben fur PROFIBUS - PA = 64 8 0x0300 Profile Revision Profd 3.0 9 0 Execution Time fix zukfinftigen Gebrauch 10 45 Number0fParameters AnzaN der Parameter 11 0x0141 Address of VIEW 1 Index von Ansicht 1 Anzahl Sr Ansichten 12 1 Number of View Lists STD 17 1 0 ST REV ldentifikabon / Ger& / Statische Rev.-Nr. / Function Block: Zahler. der bei jeder Anderung von Konfigurabonsparametem inkrementiert wird unsignedl6 visitite_stnng 1 32 N x STD 18 2 Compone nt 1 TAG_DESC eindeubge Tag im System, die der Anwender spezifizieren kann S x x STD 19 3 0 STRATEGY Strategy unsigned18 1 s x x STD 20 4 0 ALERT_KEY Wen kann van Anwender far die Alarmbehandlung geschrieben warden unsigned8 1 s x x STD 21 5 048 TARGET MODE Zielmodus des Blockes = Auto unsigned8 1 S x x 5Th 22 6 MODE BLK eingestelker Blockmodus ds37 1 D x 1 Ox08 Aetna &dueller Modus 2 Ox98 Permitted erlautite Modi: Auto. OA, MAN 3 Ox08 Normal eingestelfter Mods im Normalbetrieb STD 23 7 ALARM SUM Narmstatus ds42 1 D x 1 0x0000 Current Alarm enwarb er Alarm 2 0x0000 Unacknowledged nicht guiniert 3 0x0000 Unreported nicht gemeldet 4 0x0000 Disabled nicht freigegeben STD 24 8 BATCH Hinted Infamaticnen Ka Batch-Propane de67 1 s x x 1 BATCH ID Batch-Identifikation 2 RUP Ausstattung 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Ausgangswert: Me8wert in gewAhlter Ausgangsdarstellung. die Einhat ist in Sr Ausgangssludiening festgelegt ds33 1 D x x x 1 0 Value Ausgangswert CNA& 2 0x4F Steen MAND 27 11 PV SCALE Eingang / Megwertskalierung float 2 s x x 1 100.0 EU100 Eingang / Mellwertskalierung/Endwert zugeherige Einheit Jet Eingang / Eirtheit ausTB 2 0.0 EUO Brogan / Me8wertskalierung/Anfangswert: zugehorige Einheit ist Eingang / Eirtheit (ausTB) MAND 28 12 OUT SCALE A n /Aus a Italie ds38 1 s x x 1 100.0 EU100 Ausgang/Ausgangsskalierund 1 Endwert 2 0.0 ELIO Ausgang / Ausgangsskalierung 1 Anfangswert 3 UNIT Ausgang /Ausgangsskaherung I Einheit Physikelische Einheit fur Nagano 4 Dec_Point Stollen hinter Dezimelpunkt Angabe fur den Ausgangswert MAND 29 13 0 LIN TYPE Linearisierunsert unsigned8 1 s x x MAND 30 14 0x0109 CHANNEL Kanalnummer. Nummer des Transducer Blocks trod relative( Index unsigned18 1 s x x MAND 32 18 0.0 PV_FTIME Ausgang /Ausgangssignal / Filterzeitkonstante: Filterzeit fir Ausgangswert in Sekunden float 1 s x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 57 EFTA01216628 Function Block Al 1 (Analog Input) cont. Class SI of f Index abs Ind ex rel Elem ent Default Value Object Parameterbeschretbung Data Type Num Der Stare (acc. to profile) cy di c re ad wri to MAND 33 17 0 FSAVE_TYPE Ausgang /Austallverhalten: Art der Reaktion our Sensorausfall unsigned8 1 S x x MAND 34 18 0.0 FSAVE_VALUE Ausgang / Sicherheitsvorgatewert: Ersatzwert bei Sensorausfall float 1 S x x MAND 35 19 5.0 ALARM_HYS Ausgang / Ausgangssignal / Grenzwert- Hysterese: Alarm-Hysteresewert, Defaullwert = 5 % vom Endwen float 1 S x x MAND 37 21 100.0 HI_HI_LIM Ausgang /Ausgangsgrenzwerte/ Alarmgrenze Oben float 1 S x x MAND 39 23 100.0 HI_UM Ausgang /Ausgangsgrenzwerte/ Warngrenze Oben float 1 S x x MAND 41 25 0.0 LO_LIM Ausgang /Ausgangsgrenzwerte / Warngrenze Unten float 1 S x x MAND 43 27 0.0 LO_LO_LIM Ausgang /Ausgangsgrenzwene I Alarmgrenze Unten float 1 S x x MAND 46 30 HI HI_ALM Status des oberen Alarmgrenzwertes ds39 1 D x 1 Unacknowledged nicht quittierl 2 Alarm State Alarmstatus I 3 Time stem. Zeitstern • el I 4 Subcode Subcode I S Value Wert MAND ' 47 31 HI ALM Status des oberen Wamgrenzwertes d839 1 D x 1 Unacknowledged nicht quittied 2 Alarm State Alarmstatus p Pee S Value Wert dig° 1 0 x , . , , . 3 Time stem. Zeitstern. , 4 Subcode Subcode S Value Wert MAND 49 33 LO LO ALM Status des unteren Ala , renzwertes da39 1 D x edge 3 Time stem. Zeitstern. , 4 Subcode Subcode S Value Wert MAND 50 34 SIMULATE Ausgang / Simulation: Simulation des MeOmertes (PRIMARY VALUE im Transducer Block) ds50 1 S x x 1 Ox4b Simulate-Status Ausgang / Simulation I Status: Simulationsstatus 2 0.0 Simulate_value Ausgang / Simulation / Simutabcnswert simulierter Wert 3 0 Simulate_ENDisable Ausgang / Simulation! Simukatiat Simulation fret. • , n / to :wen. 0063u/tweet ! , -• ,rrt 0 OPT 51 35 OUT_UNIT_TEXT Einheitentext gOltig, wenn OUT SCALE.UNIT ad textual unit definition" 1995 vistle_string 16 S x x 52 38 bis resented von PNO ea 44 VIEW 85 49 VIEW 1 View-ObJekt 1 Al void 4 0 x 1 ST REV I 6 MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 58 EFTA01216629 7.5.3 Transducer Block TB 1 Transducer Block TB1 (Analyser) Class Si of index abs Ind ex rel Elem ent Default Value Object Parameterbeschreibung Data Type Nurn ber Store (ace. to profile) cy di c re ad arts Is BLOCK 2 66 0 BLOCK OBJECT Block-Charaderistic ds32 1 C x I 250 Reamed 250 = not used 2 3 Nock Object Bkick-Typ i 3 4 7 Parent Class 1 Class 5 0 DO-Reference reserved 6 0 DO-Revision reserved 7 0x4002 Profile PA-Prohl-Nummer durch PNO vergeben fir PROFIBUS-PA = 64. Class B=2 8 0x0300 Profile Revision Profit 3.0 9 0 , execution Time Mr zukrinftigen Gebrauch 10 36 Number0fParameters AnzaN der Parameter ndex Val Ansicht 1 11 Dx016d Address of VIEW 1 12 1 Number of View Lists knish! der Ansichten STD 87 1 0 ST REV 2iNer,der bet jeder Anderung Val Konfigurationsparametem inkremenfien wird unsigned16 1 N x STD 68 2 TAG_DESC sindeutige Tag int System, die der Anwender spezikfieren kann visble_string 32 S x x x STD 89 3 D STRATEGY Strategy unsignedl6 1 s x STD 70 4 D TARGET ALERT_KEY Neil kann vom Amvender Mr die Alarrnbehandlung geschrieben warden unsigned8 unsigned8 1 s x x STD 71 5 MODE 2ielmodus des Blockes = Auto 1 s x x STD 72 6 NODE BLK estate( Blockmodus ds37 1 D x 1 0x08 Actual Auto 2 0x08 'ermined Auto 3 0x08 Normal Auto STD 73 7 \ALARM SUM Alarmstatus ds42 1 D x 1 0x0000 Current Alarm gegenwartiger Alarm 2 0x0000 Unacknowledged Scht quittiert I 3 0x0000 Urrepofled nicht gemeldst 4 0x0000 Disabled nicht freigegeben MAND 74 8 Componen 1 COMPONENT_NAME Name der Komponente visble_sting 32 5 x x MAND 75 9 PV Messwert kir den Al-Bbock 1 deal 1 D x 0.0 Value 0x0B Status lime MAND 76 10 1997 PV_UNIT Einheit des Primary Value (1997 = none) unsignecl16 1 s x x MAND 77 11 PV UNIT TEXT Einheiten Text des Primary Value visible sting 8 s x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 s x x MAND 79 13 0 AUTORANGE ON boolean 1 s x x MAND 80 14 100 SAMPLING RATE Abtaslzeit in Maisekunden unsigned32 1 s x x 81 15 bis reservien durch PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 26 RANGE 1 de61 1 N x x 0.0 Begin 100.0 End SPEC 100 34 'OSITIONING VALUE ds34 1 D x 0 dalue 0x4F Status SPEC 101 35 EEDBACK ds34 1 D x 1 Value 2 Status void s D x VIEW 109 43 VIEW 1 View-Objekt 1 1 ST REV S MODE BLK 7 ALARM SUM 3 mit 12 ACTNE_FtANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 59 EFTA01216630 7.5.4 Physical Block Physical Block PB a Class SI of Index abs Ind ex rel Elem ant Default Value j00;ect Parameterbesdireibung Data Type Num bat Store Onto cy ch c re ad wit to BLOCK 1 110 0 BLOCK OBJECT Block-Characteristik ds32 1 C x 1 250 Reserved 250 = not used unsigned8 1 2 1 Block Object Elfock-Typ (Physical) unsigned8 1 3 5 Parent Class 5 = Analyser unsigned8 1 4 250 Class 250 = not used unsigned8 1 5 0 DO-Reference reserved unsipned32 1 8 0 DO-Revision reserved unsigned16 1 7 0x4002 Profile PA-Profil-Nummer durch PNO vergeben kir PROFIBUS - PA = 64, Class B=2 unsigned16 1 8 Ox0300 Profile Revision _ Profil 3.0 1 9 0 Execution Time _unsigned% for bare use unsigned8 1 10 11 54 Ox01 b7 Number0fParameters High Byte:Highest Index -Low Byte: Highest Offset unsignedl 6 1 Address of VIEW 1 unsigned16 1 12 1 Number of View Lists unsigned8 1 STD 111 1 0 ST REV _ Zahier,der bei jeder Anderung von Konfigurationsparametem inkremenbert wird unsigned16 1 N x STD 1 112 2 Analyser TAG_DESC eindeutige Tag im System, die der Anwender spezifizieren kann visble_string 32 S x x STD 113 3 0 STRATEGY Strategy unsigned16 1 S x x STD 114 4 o ALERT_KEY Wed kann van Anwender ffir die Alarmbehandlung geschrieben warden unsigned8 1 S x x STD 115 5 Ox08 TARGET MODE Zielmodus des PB = Auto unsigned8 1 S x x STD 116 6 MODE BLK eingestefiter Blockmodus ds37 1 D x 1 Ox08 Actual Auto 2 Ox88 Permitted Auto 3 0x08 Normal Auto STD 117 7 ALARM SUM Alarmstatus ds42 1 D x 1 Ox0000 Current Alarm 2 Ox0000 Unocknowl 3 Ox0000 Unreported 4 Ox0000 Disabled MAN 118 8 / 0.23 SOFTWARE_REVISION Software Revision visble_string 16 D x MAN 119 9 HARDWARE REVISION Hardware Revision visible_sbing unsignedl6 16 D x MAN 120 10 42 DEVICE MAN ID Hersteller 1 C x MAN 121 11 DEVICE ID Gerateidentifikabon (unique) visible string 16 C x MAN 122 12 DEV SER NUM GerAteseriennummer visible string 16 D x MAN 123 13 0x000000 00 DIAGNOSIS Detailliede Geriate-Info(bitweise codiert) octet_string 4 D x OPT 124 14 DIAGNOSIS EXTENSION Enveiterte Diagnose octet string 6 D MAND 125 15 OxBBBFO 000 DIAGNOSIS MASK Bits supported by DIAGNOSIS octet_string 4 C x OPT 126 18 DIAGNOSIS MASK EXTENSION Bits supported by DIAGNOSIS EXTENSION octet string 6 C OPT 127 17 CE, NE21. Ex- cerlificatio n see plate DEVICE_CERTIFICATION erkitte Zertfiziereungen Ex, CE visblitstring 32 C x OPT 128 18 2457 WRITE LOCKING Password unsigned% 1 N x x OPT 129 19 0 FACTORY RESET Rficksetzen auf Default-Warta unsigned16 1 S x x OPT 130 20 descriptor DESCRIPTOR visible fling 32 S x x OPT 131 21 message DEVICE MESSAGE Nachricht viable string 32 S x x OPT 132 22 01.01.200 0 DEVICE_INSTAL_DATE Datum der Gerfiteinstallation octet_string 16 S x x OPT 133 23 0 LOCAL OP ENA Freigabe Vor Oct Bedienung unsigned8 1 N x x MAND 134 24 1 IDENT_NUMBER_SELECTOR Profile Analyser 13F1137- (0) Profile spec. (3) Hersteller spez. (1) DP-Ident Number unsigned8 1 S x x OPT 135 25 HW WRITE PROTECTION Hardware-Schreibschutz unsigned8 1 D x 136 26 bb resenriert dutch PNO 142 32 ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 60 EFTA01216631 Physical Block PB cont. Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbeschrethung Data Type Num Der Store (acc. to ofile cy di c re ad wn to additional parameters for analysers MAND 146 36 PROFIBU S option 2 DEVICE_CONFIGURATION vistle_string 32 N x MAND 147 37 INIT STATE Status nark Reset unsigned8 1 S x x MAND 148 38 2 DEVICE STATE Status des Carets unsigned8 1 D x x MAND 149 39 0 GLOBAL STATUS unsigned18 1 D x 150 40 bb resented durch PNO 157 47 SPEC 158 48 DIAGNOSIS SIMULATION Diagnose-Simulation record 2 D x x 1 0x000000 00 Value simulienes DIAGNOSIS-Objekt octet_string 4 2 0 Enable Freigabe der Diagnose-Simulation 0: gesperrt 1: freigegeben unsigned8 1 SPEC 159 49 1 DIAGNOSIS_ALARM_ENABLE Unterdruckung von zyklischen Diagnosetelegrammen unsigned8 1 S x x SPEC 160 SO CALIBRATION DATA Kalibrierdaten record 2 S x x Data Kalibrierdatum octet string 8 Who Kalibrierstelle visible string 24 SPEC 161 51 PRODUCT_CODE Bestellntnmer (MLFB- Nr/Auslieferungszustand) visble_string 32 D x SPEC 162 52 0x000000 00 ERRORS vorhandene FeNer octet_string 4 D x SPEC 163 53 0x0000 WARNI4GS vorhandene Wamungen octet string 2 D x VIEW 183 73 VIEW 1 View-Objekt 1 PB void 6 D x 1 1 ST REV 2 6 MODE BLK 3 7 ALARM SUM 4 13 DIAGNOSIS 5 38 DEVICE STATE 6 39 GLOBAL STATUS ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 61 EFTA01216632 7.5.5 Function Block Al 2 Function Block Al 2 (Analog Input) re ad I wit to Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbescnreibung Data Type Num bet Store (acc. to profile) cy cl, c BLOCK 2 16 0 BLOCK OBJECT Block-Characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Typ (Function) 3 1 Parent Class Obergeordnete lasses: 01 = Input 4 1 Class Masse: 01 = Analog Input 5 0 DO-Reference reseiviert 8 0 DO-Revisal resented 7 Ox4001 Profile PA-Profil-Nummer durch PNO vergeben fur PROFIBUS - PA = 64 8 0x0300 Profile Revision Profit 3.0 9 0 Execution Time Km zukfinftigen Gebrauch 10 45 Number0fParameters AnzeN der Parameter 11 0x0141 Address of VIEW 1 Index von Amuck 1 Anzahl der Ansichten 12 1 Number of View Lists STD 17 1 0 ST REV Identifikabon / Garet / Statische Rev.-Nr. / Function Block: Zahler. der bei jeder Anderung von Konfigurabonsparametem inkrementiert wird unsignedl6 visibte_stnng 1 32 N x STD 18 2 Compone N 2 TAG_DESC eiideutige Tag im System, die der Anwender spezifizieren kann S x x STD 19 3 0 STRATEGY St ategy unsigned113 1 s x x STD 20 4 0 ALERT_KEY Wen kann yam Anwender fur die Alermbehandlung geschdeben warden unsigned8 1 s x x STD 21 5 Ox08 TARGET MODE Zelmodus des Blockes = Auto unsigned8 1 S x x 5Th 22 6 MODE BLK eingestelker Blockmodus ds37 1 D x 1 Ox08 Antral &dueller Modus 2 Ox98 Permitted erlautite Modi: Auto. OA, MAN 3 Ox08 Normal eingestelfter Modus im Normalbetrieb STD 23 7 ALARM SUM Narmstatus da42 1 D x 1 0x0000 Current Alarm enwarti er Alarm 2 0x0000 Unacknowl d nicht quiniert 3 0x0000 Unreported nicht gemeldet 4 0x0000 Disabled nicht freigegeben STD 24 8 BATCH Hinted Infamaticnen fOr Batch-Possess de67 1 s x x 1 BATCH ID Batch-Identifikation 2 RUP Ausstattung 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Ausgangswert: Me8wert in gewAhlter Ausgangsdarsteltung. die Einhat ist in Sr Ausoangssludiening festgelegt ds33 1 0 x x x 1 0 Value Ausgangswert CNA& 2 0x4F Star= MAND 27 11 PV SCALE Eingang / Mefawertskalierung float 2 s x x 1 100.0 EU100 Eingang / Mefimertskalierung/Endwart zugeherige Einheit let Eingang / Eirthek ausTB 2 0.0 EUO Brogan / Meilwertskalierung/Anfangswert zugehorige Einheit ist Eingang / Eirthek (ausTB) MAND 28 12 OUT SCALE Ausgang /Ausgangssicaliatung ds38 1 s x x 1 100.0 EU100 Ausoang / Ausgangsskalietuno 1 Endwert 2 0.0 ELIO Ausgang / Ausgangsskalietung 1 Anfangswert 3 UNIT Ausgang / Ausgangsskalietung I Einheit Physikalische Einheit fur Nagano 4 Dec_Point Steller inter Dezimalpunkt Ameba fur den Ausgangswert MAND 29 13 0 LIN TYPE Linearisierunsert unsigned8 1 s x x MAND 30 14 0x0209 CHANNEL Kanalnummer. Nummer des Transducer Blocks trod relative( Index unsignedl8 1 s x x MAND 32 18 0.0 PV_FTIME Ausgang /Ausgangssignal / Filterzeitkonstante: Filterzeit fen Ausgangswert it Sekunden float 1 s x x MAND 33 17 0 FSAVE_TYPE Ausgang /Ausfallverhalten: Art der Reaktion auf Sensorausfall unsigned8 1 s x x MAND 34 18 0 FSAVE VALUE Ausgang / Sicherheitsvorgabewert: Ersatzwert bei Sensorausfall float 1 s x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 62 EFTA01216633 Function Block Al 2 (Analog Input) cont. 4i wit to Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbeschreibung Data Type Num ber Store icy (acc. to profile) a c re ad MAND 35 19 5.0 ALAFtM_HYS Ausgang / Ausgangssignal / Grenzwert- Hysterese: Alarm-Hysteresewen Defaultwen = 5 % vom Endwen float 1 S x x MAND 37 21 100.0 HI_HI_LIM Ausgang /Ausgangsgrenzwerte/ Alarmgrenze Oben float 1 S x x MAND 39 23 100.0 HI_LIM Ausgang /Ausgengsgrenzwerte/ Warngrenze Oben float 1 S x x MAND 41 25 0.0 LO_LIM Ausgang /Ausgengsgrenzwerte / Warngrenze unten float 1 S x x MAND 43 27 0.0 LO_LO_LIM Ausgang /Ausgangsgrenzwerte / Alarmgrenze Unten float 1 S x x MAND 46 30 HI HI ALM Status des oberen Alarm renzwertes ds39 1 D x 1 Unacknowl d nicht untied 2 Alarm State Atermstetus 3 Time stem 2eitstem 4 Subcode Suboode S Value Wert MAND 47 31 HI ALM Status des oberen Wam rertzwenes da39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alarmstatus 3 Time stem 2eitstem el 4 Subcode Suboode S Value Wert MAND 48 32 LO ALM Status des unteren Wamgrenzwertes da39 1 D x 1 Unacknowl d nichtquitted 2 Alarm State Atermstetin 3 lime stem 2eitstem 4 Subcode Suboode S Value Wert MAND 49 33 LO LO ALM Status des unteren Alarmgrenzwertes ds39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alermstetus 3 Time stem 2eitstem 4 Subcode Suboode S Value Wert MAND SO 34 SIMULATE Ausgang / Simulation: Simulation des Megwertes (PRIMARY VALUE im Transducer Block) ds50 1 S x x 1 0x4b Simulate-Status Ausgang / Simulation I Status: Simulationsstatus 2 0.0 Simulate_value Ausgang / Simulation / Simuleticnswert simulierter Wert 3 0 Simulate_En/Disable Ausgang / Simulation! Simukabat Simulation freigeben / apemen. Defauffwert °aspen? (0) OPT 51 35 OUT_UNIT_TEXT Enheitentext gulag, wenn OUT SCALE.UNIT auf 'textual unit definition" (1995) vistatelrIng 16 S x x 52 36 bis resenAert von PNO 80 44 VIEW 66 49 VIEW 1 View-Objekt 1 Al void 4 o x 1 ST REV 6 MODE BLK 7 ALARM SUM ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 63 EFTA01216634 7.5.6 Transducer Block 2 Transducer Block TB2 (Analyser) Class SI of Index abs Ind ex rel Bern ent Default Value Object Parameterbeschreibung Data Type Worn Der Store (am to profile) cy di c re a0 arts le BLOCK 2 66 0 BLOCK OBJECT Block-Charaderistic 0,332 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Block-Typ 3 7 Parent Class 4 1 Class 5 0 DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4002 Profile PA-Profil-Nummer durch PNO vergeben fiir PROFIBUS - PA = 64. Class B=2 8 0x0300 Profile Revision Profd 3.0 9 0 Execution Time Km zukinftigen Gebrauch 10 27 Number0fParameters AnzaN der Parameter i 11 0x026d Address of VIEW 1 Index von Ansichi 1 Anzahl der Ansichten _ 12 1 Number of View Lists STD 67 1 0 ST REV Zahler,der bei jederAnderung von Konfigurationsparametem inkremenben wid eindeutige Tag im System, die der Amender spezifizieren kann unsigned16 1 N x x x STD 68 2 TAG_DESC visible_string 32 S STD 69 3 0 STRATEGY Strategy Wen kann yam Anwender ftir die Alarmbehandluno peschrieben warden unsigned% 1 S x x x STD 70 4 0 ALERT_KEY unsigned8 1 S x STD 71 5 Ox08 TARGET MODE Zielmodus des Blockes = Auto unsigned8 1 S x x STD 72 6 MODE _BLK eigestellter Blockmodus ds37 1 D x 1 Ox08 Actual Auto 2 Ox08 Permitted Auto 3 Ox08 Normal Auto STD 73 7 ALARM SUM Alarmstetus ds42 1 D x 1 Ox0000 Current Alarm gegenwertiger Alarm 2 04000 Unacknowledged nicht quittierl 3 04000 Unreported richt gemeldet I 4 Ox0000 Disable ae ridlt n MAND 74 8 Compone nt 2 COIiWONENT_NAME Name der Komponente visible_string 32 5 x x MAND 75 9 PV Messwert ffir den AI-Block 1 de60 1 D x 0.0 Value Ox0B Status Time MAND 76 10 1097 PV UNIT Einheit des Primer/Value (1997 = none) unsigned% 1 S x x MAND 77 11 PV_UNIT_TEXT Einheiten Text des Primary Value visble_string 8 S x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON boolean 1 S x x MAND 80 14 400 SAMPLING RATE Abtastze4 in Meisekunden unsigned32 1 S x x 81 15 bls resented ditch PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsIgned8 1 C x MAND 92 28 RANGE 1 de61 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 D x 1 ST REV 6 MODE BLK 7 ALARM SUM 11 ACTIVE RANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216635 7.5.7 Function Block Al 3 Function Block Al 3 (Analog Input) re ad I wit to Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbescnreibung Data Type Num bet Store (acc. to profile) cy cl, c BLOCK 3 16 0 BLOCK OBJECT Block-Characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Typ (Function) 3 1 Parent Class Obergeordnete lasses: 01 = Input 4 1 Class Masse: 01 = Analog Input 5 0 DO-Reference reseiviert 8 0 DO-Revisal resented 7 Ox4001 Profile PA-Profil-Nummer durch PNO vergeben fur PROFIBUS - PA = 64 8 0x0300 Profile Revision Profit 3.0 9 0 Execution Time Km zukfinftigen Gebrauch 10 45 Number0fParameters AnzeN der Parameter 11 0x0341 Address of VIEW 1 Index von Amutht 1 Anzahl Sr Ansichten 12 1 Number of View Lists STD 17 1 0 ST REV ldentifikabon / Ger& / Statische Rev.-Nr. / Function Block: Zahler. der bei jeder Anderung von Konfigurabonsparametem inkrementiert wird unsignedl6 visibte_stnng 1 32 N x STD 18 2 Compone N 3 TAG_DESC eiideutige Tag im System, die der Anwender spezifizieren kann S x x STD 19 3 0 STRATEGY St ategy unsigned18 1 S x x STD 20 4 0 ALERT_KEY Wen kann van Anwender far die Alermbehandlung geschrieben warden unsigned8 1 S x x STD 21 5 0x08 TARGET MODE Zelmodus des Blockes = Auto unsigned8 1 5 x x STD 22 6 MODE BLK eingestelker Blockmodus ds37 1 D x 1 0x08 Antral &dueller Modus 2 0x98 Permitted erlautite Modi: Auto. 0/5, MAN 3 Ox08 Normal eingestelfter Mods im Normalbetrieb STD 23 7 ALARM SUM Narmstatus da42 1 D x 1 ox0000 Current Alarm enwarti er Alarm 2 0x0000 Unacknowl d nicht quiniert 3 0x0000 Unreported nicht gemeldet 4 0x0000 Disabled nicht freigegeben STD 24 8 BATCH Hinted Infamaticnen fOr Betch-Prozesse de67 1 s x x 1 BATCH ID Batch-Identifikation 2 RUP Ausstattung 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Ausgangswert: Me6wert in gewAhlter Ausgangsdarsteltung. die Einhat ist in Sr Ausoangssludiening festgelegt ds33 1 0 x x x 1 0 Value Ausgangswert CNA& 2 0x4F Star= MAND 27 11 PV SCALE Eingang / Mefawertskalierung float 2 s x x 1 100.0 EU100 Eingang / Mellwertskalierung/Endwert zugeherige Einheit let Eingang / Eirtheit ausTB 2 0.0 EUO Brogan / Meilwertskalierung/Anfangswert zugehorige Einheit ist Eingang / Eirtheit (ausTB) MAND 28 12 OUT SCALE Ausgang /Ausgangssicaliatung ds38 1 s x x 1 100.0 EU100 Ausoang / Ausgangsskalietuno 1 Endwert 2 0.0 ELIO Ausgang / Ausgangsskalietung 1 Anfangswert 3 UNIT Ausgang / Ausgangsskalietung I Einheit Physikelische Einheit fur Nagano 4 Dec_Point Steller tinter Dezimelpunkt Ameba fur den Ausgangswert MAND 29 13 0 LIN TYPE Linearisierunsert unsigned8 1 s x x MAND 30 14 0x0309 CHANNEL Kanalnummer. Nummer des Transducer Blocks trod relative( Index unsigned18 1 s x x MAND 32 18 0.0 PV_FTIME Ausgang /Ausgangssignal / Filterzeitkonstante: Filterzeit fen Ausgangswert it Sekunden float 1 s x x MAND 33 17 0 FSAVE_TYPE Ausgang /Ausfallverhalten: Art der Reaktion auf Sensorausfall unsigned8 1 s x x MAND 34 18 0 FSAVE VALUE Ausgang / Sicherheitsvorgabewert: Ersatzwert bei Sensorausfall float 1 S x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 65 EFTA01216636 Function Block Al 3 (Analog Input) cont. 4i wit to Class SI of Index abs Ind ex rel Elem ent Default Value Object Paramsterbeschreibung Data Type Num ber Store icy (acc. to profile) a c re ad MAND 35 19 5.0 ALAFtM_HYS Ausgang / Ausgangssignal / Grenzwert- Hysterese: Alarm-Hysteresewert, Defaultwen = 5 % vom Endwen float 1 S x x MAND 37 21 100.0 HI_HI_LIM Ausgang /Ausgangsgrenzwerte/ Alarmgrenze Oben float 1 S x x MAND 39 23 100.0 HI_LIM Ausgang /Ausgengsgrenzwerte/ Warngrenze Oben float 1 S x x MAND AM 25 0.0 LO_LIM Ausgang /Ausgengsgrenzwerte / Warngrenze unten float 1 S x x MAND 43 27 0.0 LO_LO_LIM Ausgang /Ausgengsgrenzwerte / Alarmgrenze Unten float 1 S x x MAND 46 30 HI HI ALM Status des oberen Alarm renzwertes ds39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alarmstatus 3 Time stamp 2eitstempel 4 Subcode Suboode S Value Wert MAND 47 31 HI ALM Status des oberen Wamgrenzwertes da39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alarmstatus 3 Time stamp 2eitstem el 4 Subcode Suboode S Value Wert MAND 48 32 LO ALM Status des unteren Wamgrenzwertes da39 1 D x 1 Unacknowledged nicht quilbed 2 Alarm State Alarmstatus 3 lime stamp 2eitstempel 4 Subcode Suboode S Value Wert MAND 49 33 LO LO ALM Status des unteren Alarmgrenzwertes ds39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alermstetus 3 Time stamp 2eitstempel 4 Subcode Suboode S Value Wert MAND SO 34 SIMULATE Ausgang / Simulation: Simulation des Megwertes (PRIMARY VALUE im Transducer Block) ds50 1 S x x 1 Ox4b Simulate-Status Ausgang / Simulation I Status: Simulationsstatus 2 0.0 Simulate_value Ausgang / Simulation / Simuleticnswert simulierter Wert 3 0 Simulate_En/Disable Ausgang / Simulation! Simukabat Simulation freigeben / apemen. Defauffwert °aspen? (0) OPT 51 35 OUT_UNIT_TEXT Enheitentext gulag, wenn OUT SCALE.UNIT auf 'textual unit definition" (1995) visigefirIng 16 5 x x 52 36 bis resenAert von PNO 80 40 VIEW 66 49 VIEW 1 View-Objekt 1 AI void 4 D x 1 ST REV s MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 66 EFTA01216637 7.5.8 Transducer Block TB 3 Transducer Block TB 3 (Analyser) Class SI of index abs Ind ex rel Elem ent Default Value Object I Parameterbeschreibung Data Type Num Per Store (ace. to profile) cy di c re ad arts le BLOCK 3 66 0 BLOCK OBJECT Wock-Charaderistk ds32 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Block-Typ 3 7 Parent Class 4 5 1 0 Class DO-Reference reserved 8 0 DD-Revision reserved I 7 0x4002 Profile PA-Profil-Nummer dutch PNO vergeben fur PROFIBUS - PA = 64. Class 8=2 8 0x0300 Profile Revision Prof 3.0 9 0 Execution Time ffir zukinftigen Gebrauch 10 27 NumberOfParameters AnzaN der Parameter 11 12 0x036d 1 Address of VIEW 1 Number of View Lists Index von Ansichi 1 Anzahl der Ansichten STD 67 1 0 ST REV ZAhler,der bei jederAnderung von Konfigurationsparametem inkremenben wed eindeutige Tag im System, die der Anwender spezifizieren kann unsigned16 1 N x x x STD 88 2 Compone nt 3 TAG_DESC vimble_string 32 S STD 69 3 0 STRATEGY Strategy Wen kann vom Anwender fie die Alarmbehandlunp peschrieben warden unsigned16 1 S x x x STD 70 4 0 ALERT_KEY unsigned8 1 S x STD 71 5 0x08 TARGET MODE Zelmodus des Blockes = Auto unsigned8 1 S x x STD 72 6 MODE BLK estellter Blockmodus ds37 1 o x 1 0x08 Actual Auto 2 0x08 Permitted Auto 3 0x08 Normal Auto STD 73 7 ALARM SUM Alarmstetus ds42 1 D x 1 0x0000 current Alarm gegenwertiger Alarm 2 0x0000 Unacknowledged nicht quitten 3 0x0000 Unreported richt gemeldet I 4 0x0000 Disabled richt freigegeben x MAND 74 8 COMPONENT NAME Name der Komponente visible string 32 5 x MAND 75 9 PV Messwert Kir den AI-Block 1 ds60 1 D x 0.0 Value 0x0B Status Time x MAND 76 10 1697 PV UNIT Einheit des Primary Value (1997 = none) unsigned16 1 S x MAND 77 11 PV UNIT TEXT Einheiten Text des PrimaryValue visible sting 8 s x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON boolean 1 S x x MAND 80 14 300 SAMPLING RATE Ablest:reit In Masekunden unsigned32 1 S x x 81 15 bis resennen dutch PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 26 RANGE 1 de61 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 o x 1 ST REV 6 MODE BLK 7 ALARM SUM 11 ACTIVE RANGE 8 PV ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 67 EFTA01216638 7.5.9 Function Block Al 4 Function Block Al 4 (Analog Input) re ad 1 wit Is Class SI of Index abs Ind ex rel Elem ent Default Value Object I Parameterbeschrenung Data Type Num bet Store (acc. to profile) cy c BLOC K 4 16 0 BLOCK OBJECT Block-Characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Typ (Function) 3 1 Parent Class Obergeordnete Klasse: 01= Input 4 1 Class Masse: 01 = Analog Input 5 0 DD-Reference reserviert 6 0 DD-Revision reserviert 7 Ox4001 Profile PA-Profil-Nummer lurch PNO vergeben fiir PROFIBUS - PA = 64 8 0x0300 Profile Revision Profit 3 0 9 0 Execution Time fur zukunffigen Gebrauch 10 45 Number0fParameters AnzaN der Parameter 11 0x0441 Address of VIEW 1 Index von Ansichi 1 12 1 Number of View Lists Anzahl der Ansichten STD 17 1 0 ST REV Identifikabon/ Garin / Statische Rev.-Nr. / Function Block: Zahler. der bei jeder Anderung von Konfigurabonsparametem inkrementiert wird unsigned16 1 N x STD 18 2 Compone nt 4 TAG_DESC endeubge Tag im System, die der Anwender spezifizieren kann visitle_stnng 32 S x x STD 19 3 0 STRATEGY Strategy unsigned18 1 S x x STD 20 4 0 ALERT_KEY Wed kann vem Anwender IN die Alarmbehandlunp peschrieben warden unsigned8 1 S x x STD STD 21 22 5 6 0x08 TARGET MODE Zielmodus des Blockes = Auto unsigned8 1 S x x MODE BLK . •estelfter Blockmodus de37 1 o x 1 0x08 Actual aktueller Modus 2 048 Permitted erlaubte Modi: Auto. 0/S. MAN 3 Ox08 Normal eingestelfter Modus im Normalbetrieb STD 23 7 ALARM SUM Alarmstatus dM2 1 D x 1 0x0000 Current Alarm gegenwartiger Alarm 2 0x0000 UnacknoM-• d Mehl • uitlien 3 0x0000 Unreported richt gemeldet 4 0x0000 Disabled richt ' eben STD 24 8 BATCH Hinterlegte Informaticaen fur Batch-Prozesse de67 1 S x x 1 BATCH ID Batch-Identifikation 2 RUP Ausstattung 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Ausgangswert: Me6wert in gewahtter Ausgangsdarstellung, die Einheit ist in der Ausgangsskalierung festgelegt de33 1 D x x x 1 0 Value Ausgangswert 2 0x4F States Oualitit MAND 27 11 PV SCALE Eingang/ Mefimertskalierung Eingang/ Mellwenskalierung/Endwert zugehorige Einheit ist Eingang / Einheit (ausTEI) float 2 s x x 1 100.0 EU100 2 0.0 EU0 Eingang / Me8wertskalierung/Anfangswert zugehorige Einheit ist Eingang / Eirtiek jausTB) MAND 28 12 OUT SCALE Ausgang /AusgangssIcalimung ds38 1 S x x 1 100.0 EU100 Ausgang /Ausgangsskaliwung I Endwert 2 0.0 EU0 Ausgang /AusgangssIcaliwung 1 Anfangswed 3 UNIT Ausgang /AusgangssIcaliwung I Einheit Physikalische Einheit Kir Ausgang 4 Dec_Point &ellen tinter Dezimalpunkt. Angabe fur den Ausgangswert MAND 29 13 0 LIN TYPE Linearisierunsart unsigned8 1 S x x MAND 30 14 0x0409 CHANNEL Kanalnummer. Nummer des Transducer Blocks und relatives Index unsigned18 1 S x x MAND 32 18 0.0 PV_FTIME Ausgang /Ausgangssignal / Filterzeitkonstante: Filterzeit far Ausgangswert in Sekunden float 1 S x x MAND 33 17 0 FSAVE_TYPE Ausgang /Ausfallverhalten: Art der Reaktion aid Sensorausfall unsigned8 1 S x x MAND 34 18 0 FSAVE_VALUE Ausgang / Sicherheitsvorgabewert: Ersatzwert bei Sensorausfall float 1 S x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 68 EFTA01216639 Function Block Al 4 (Analog Input) cont. 4i wed to Class SI of Index abs Ind ex rel Elem eat Default Value Object Paramoterbescnreibung Data Type Num ber Store icy (acc. to profile) a c re ad MAND 35 19 5.0 ALAFtM_HYS Ausgang / Ausgangssignal / Grenzwert- Hysterese: Alarm-Hysteresewert, Defaultwen = 5 % vom Endwen float 1 S x x MAND 37 21 100 HI_HI_LIM Ausgang /Ausgangsgrenzwerte/ Alarmgrenze Oben float 1 S x x MAND 39 23 100 HI_LIM Ausgang /Ausgengsgrenzwerte/ Warngrenze Oben float 1 S x x MAND 41 25 0 LO_LIM Ausgang /Ausgengsgrenzwerte / Warngrenze amen float 1 S x x MAND 43 27 0 LO_LO_LIM Ausgang /Ausgengsgrenzwerte / Alarmgrenze Unten float 1 S x x MAND 46 30 HI HI ALM Status des oberen Alarm renzwertes ds39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alarmstatus 3 lime stamp 2eitstempel 4 Subcode Subcode S Value Wert MAND 47 31 HI ALM Status des oberen Wamgrenzwertes da39 1 D x 1 Unacknowledged nicht quitted 2 Alarm State Alarmstatus 3 lime stamp 2eitstem el 4 Subcode Subcode S Value Wert MAND 48 32 LO ALM Status des unteren Wamgrenzwertes da39 1 D x 1 Unacknowledged rice quitter 2 Alarm State Alarmstatus 3 lime stamp 2eitstempel 4 Subcode Subcode S Value Wert MAND 49 33 LO LO ALM Status des unteren Alarmgrenzwertes ds39 1 D x 1 Unacknowledged nicht quelled 2 Alarm State Alermstetus 3 lime stamp 2eitstempel 4 Subcode Subcode S Value Wen MAND SO 34 SIMULATE Ausgang / Simulation: Simulation des Megwertes (PRIMARY VALUE im Transducer Block) ds50 1 S x x 1 0x4ti Simulate-Status Ausgang / Simulation I Status: Simulationsstatus 2 0.0 Simulate_value Ausgang / Simulation / Simuleticnswert simulierter Wert 3 0 Simulate_En/Disable Ausgang / Simulation! Simukabcci: Simulation freigeben / apemen. Defauffwert °aspen? (0) OPT 51 35 OUT_UNIT_TEXT Enheitentext gulag, wenn OUT SCALE.UNIT auf 'textual unit definition" (1995) vistlefirIng 16 S x x 52 36 les resenAert von PNO 80 44 VIEW 85 49 VIEW 1 View-Objekt 1 Al void 4 D x 1 ST REV s MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 69 EFTA01216640 7.5.10 Transducer Block TB 4 Transducer Block TB 4 (Analyser) Class SI of Index abs Ind ex rel Bern ent Default Value Object Parameterbeschreibung Data Type Worn her Store (am. to profile) cy di c re ad arts le BLOCK 0 66 0 BLOCK OBJECT Block-Characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Block-Typ 3 7 Parent Class 4 1 Class 5 0 DO-Reference reserved 8 0 DD-Revision reserved I 7 0x4002 Profile PA-Profil-Nummer durch PNO vergeben fiir PROFIBUS - PA = 64. Class 8=2 8 0x0300 Profile Revision Profd 36 9 0 Execution Time Kw zukinftigen Gebrauch 10 27 Number0fParameters AnzaN der Parameter 11 Ox048d Address of VIEW 1 Number of View Lists Index von Ansichi 1 Anzahl der Ansichten 12 1 STD 67 1 0 ST REV ZAhler,der bei jederAnderung von Konfigurationsparametem inkremenben wed eindeutige Tag im System, die der Anwender spezifizieren kann unsigned16 1 N x x x STD 88 2 Compone nt 4 TAG_DESC vimble_string 32 S STD 69 3 0 STRATEGY Strategy Wed kann yam Anwender ftir die Alarmbehandlunp peschrieben warden unsigned18 1 S x x x STD 70 4 0 ALERT_KEY unsigned8 1 S x STD 71 5 Ox08 TARGET MODE Zielmodus des Blockes = Auto unsigned8 1 S x x STD 72 6 MODE BLK estellter Blockmodus ds37 1 D x 1 Ox08 Actual Auto 2 Ox08 Permitted Auto 3 Ox08 Normal Auto STD 73 7 ALARM SUM Alarmstetus ds42 1 D x 1 Ox0000 Current Alarm gegenwertiger Alarm 2 0x0000 Unacknowledged nicht quittierl 3 0x0000 Unreported richt gemeldet I 4 0x0000 Disabled richt ' eben MAND 74 8 Compone nt 4 COIiWONENT_NAME Name der Komponente vimble_string 32 5 x x MAND 75 9 PV Messwert ffir den AI-Block 1 de60 1 D x 0.0 Value OxOB Status Time MAND 76 10 1097 PV UNIT Einheit des Primer/ Value (1997 = none) unsigned18 1 S x x MAND 77 11 PV UNIT TEXT Einheiten Text des Primary Value visble_string 8 S x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON boolean 1 S x x MAND 80 14 400 SAMPL1t4G RATE Abtastze4 in Meisekunden unsigned32 1 S x x 81 15 bls resented ditch PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 28 RANGE 1 de61 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 D x 1 ST REV 6 MODE BLK 7 ALARM SUM 11 ACTIVE RANGE a PV ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 70 EFTA01216641 7.5.11 Function Block DO Function Block DO (Digital Output) Class SI of Index abs Ind ex rel Bern ent Default Value Object I Parameterbeschreibung Data Type Mon Der Store (ace. to profile) cy c re ad wit to BLOC K S t6 0 BLOCK OBJECT Block-Characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Tw (Function) 3 2 Parent Class 02= Output 4 2 Class 02 = Discrete Output S 0 DO-Reference reserved 8 0 DO-Revision reserved 7 0x4002 Profile PA-Profil-Nummer durch PNO vergeben fur PROFIBUS - PA = 64. Class B=2 8 9 0x0300 0 Profile Revision Profd 3.0 wird vor. in Juni verabschiedet Execution Time for future use 10 45 Number0fParameters High Byte:Highest Index -Low Byte: Highest Offset 11 0x054b Address of VIEW 1 12 1 Number of View Lists STD 17 1 0 ST REV Zahler,der bei jederAnderung von Konfigurationsparametem inkremenbert wed unsignediB 1 N x STD 18 2 TAG_DESC eindeutige Tag im System, die der Anwender spezifizieren kann Strategy visible_string unsignediB 32 1 S S x x x x STD 19 3 0 STRATEGY STD 20 4 0 Ox08 ALERT_KEY Wert kann vem Anwender far die Alarmbehandlung geschdeben warden unsignedS unsigned8 1 1 S x x STD 21 5 TARGET MODE Zielmodus dee PB = Auto S x x STD 22 6 MODE BLK ekgestellter Blockmodus ds37 1 D x 1 Ox08 Actual Auto 2 Ox98 Permitted Auto. 0./S, MAN 3 Ox08 Normal Auto STD 23 7 ALARM SUM Alarmstetus dM2 1 D x 1 Ox0000 Current Alarm gegenwartiger Alarm 2 Ox0000 Unacknowledged nicht quittiert 3 Ox0000 Uwe oiled nicht meldet 4 Ox0000 Disabled nicht freigegeben STD 24 8 BATCH Hinterlegte Infamaticnen Ka Batch-Prom:see de67 1 5 x x 1 BATCH ID 2 RUP 3 OPERATION 4 PHASE MAND 25 9 0 Value de34 1 D x x Ox1B Stable 0(A). M(B) 26 10 6,34 1 D x x 0 Value 12. Ox4F Statue OPT 28 de34 1 D x 0 Value Ox4F Stable 0(A). MB 30 14 de34 1 D x x 0 Value Ox1B Status SPEC Ox0123 IN_CHANNEL Zaiger aid den einzulesenden hawed (FEEDBACK) unsignediB 1 N 0(A). M(B) 33 17 Ox0122 CHANNEL Zeiger auf den zu schreibenden Outwert (POSITIONING VALUE) unsignediB 1 S x x MAND 34 18 0 INVERT unsignedS 1 S x x 0(A). M(B) 35 19 30.0 FSAVE_TIME float 1 S x x 0(A). M(B) 36 20 1 FSAVE_TYPE unsignedS 1 S x x 0(A). M(B) 37 21 0 unsignedS 1 S x x x 0(A). M(B) 38 22 ds34 1 D 0 Value ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 71 EFTA01216642 Function Block DO (Digital Output) cont. I von to Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbeschretbung Data Type Num bar Store Icy (acc. to profile) c re ad 0x4F Status O(A), M(B) 40 24 SIMULATE dal 1 S x x o Steals 0 Value 0 Enabled MAND 49 33 0x000000 CHECKBACK octet string 3 D x MAND SO 34 0x000000 CHECKBACK MASK octet string 3 C x 51 35 bIs resell/ ten van der PNO ea 44 VIEW 75 59 VIEW 1 View-Oblekt 1 void 3 D x 1 ST REV 6 MODE BLK 7 ALARM SUM Notizen / notes: ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 72 EFTA01216643 1 Information for the User This description applies to the following ULTRAMAT 6 OXYMAT 6 CALOMAT 6 ULTRAMAT/OXYMAT 6 ULTRAMAT 23 OXYMAT 61 SIEMENS gas analyzers: 7M62111, 7MB2112, 7MB2117, 7MB2121, 7MB2123, 7MB2124, 7M82127, 7MB2128 7M82011, 7MB2017, 7MB2021, 7MB2027 7M82511, 7MB2521 7M82023, 7MB2028 7M82331, 7MB2333, 7MB2334 7MB2001 This description provides important information on, additions to and corrections to the respective device manuals. PROFIBUS networks should be set up with components from the ST PI catalog. Order numbers: E86060-K4660-A101-A3 (German) or E86060-K4660-A101-A3-7600 (English) You will find information on the setup of PROFIBUS networks in the "PROFIBUS Networks" manual: Order numbers: 6GK1970-5CA10-0AA0 (German) 6GK1970-5CA10-0AA1 (English). 6GK1970-5CA10-0AA2 (French) 6GK1970-5CA10-0AA3 (Spanish) 6GK1970-5CA10-0AA4 (Italian) You will find information about PROFIBUS and SIEMENS M I at http://www.ad.siemens.de/profibus/html 00/ueber. htm: You can also obtain further information from the Profibus user organization or on the Internet at Address: PROFIBUS Nutzerorganisation Haid-und-Neu-Str. 7 D-76131 Karlsruhe Tel.: +49 721 / 96 58 590 Fax: +49 721 / 96 58 589 ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 73 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216644 1.1. Safety Notes Meaning of notices Warning Means that failure to take the necessary safety precautions may lead to death, serious injury and/or considerable material damage. Note Important information about the product, the handling of the product or that part of the manual to which special attention is to be drawn. ntroduction This description is an instruction manual according to the guidelines from the European Community Council dated 23 March 1994 (94/9/EC). It contains basic instructions on installation, connection and commissioning. This manual is a supplement to the device manual. The device manuals are included with the gas analyzers. This description is an essential part of the scope of delivery. For reasons of simplicity it does not contain all details on all versions of the described product and can also not cover every situation which could arise during installation, operation, maintenance and use in systems. If you require further information or if problems which are not dealt with in sufficient detail in this document arise, please request the desired information from your local or responsible Siemens branch. We recommend consulting our advisors about your application before using the device for new applications, for example in research and development. Safe Operation The devices and modules left the factory in perfect working order. Please follow the instructions and observe the warnings in this manual in order to maintain this condition and to ensure safe operation of the device. ULTRAMAT 6 / OXYMAT 61 CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 74 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216645 Qualified Personnel are, according to this manual, persons who are familiar with the installation, commissioning and operation of this product and have sufficient qualifications for their work, for example: O Training or instruction or authorization to switch on/off, ground and label circuits and devices or systems in accordance with the latest safety standards. O Training or instruction according to the latest standards of safety engineering in the care and use of suitable safety equipment. O Training in first aid. O For explosion protection: Training or instruction or authorization to perform work on electrical circuits for systems where there is a risk of explosion. Warning The devices may only be installed and commissioned by qualified and qualified personnel. Safety regulations for systems where there is a risk of explosion must be observed where applicable. Car Note Trouble-free and reliable operation of this device is conditional upon the proper storage, installation and assembly as well as careful operation and maintenance. Note EMC Screened cables must be used and the screen winding connected to the socket or connector housing to ensure the specified electromagnetic compatibility. Note Setup of PROFIBUS networks The following manuals describe the setup of PROFIBUS networks: DP/PA Bus Interface Edition 2 Order number 6ES7 157-0AA00-8AA0 and Manual for PROFIBUS Networks Order number 6GK1 970-5CA10-0AA0 (German) or 6GK1 970-5CA10-0AA1 (English) Documentation Package Order number 6ES7 398-8RA00-6AA0 Warning Equipment with type of protection "Intrinsic Safety" will loose ist approval if it is operated at current loops which do not comply to the requirements of the EC type conformity examination. ULTRAMAT 6 I OXYMAT 61 CALOMAT 61 ULTRAMAT 23 I OXYMAT 61 75 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216646 1.2. PROFIBUS Properties The PROFIBUS (PROcess Field BUS) is an open communication system for automation technology. The SIEMENS gas analyzers ULTRAMAT, OXYMAT and CALOMAT can be connected to the PROFIBUS- PA or the PROFIBUS-DP using optional modules. 1.2.1 PROFIBUS-PA PROFIBUS-DP Communication Protocol IEC-1158-2 Transmission Technique PROFIBUS-PA The A5E00015899 Exi optional module allows intrinsically safe coupling to PROFIBUS-PA. The A5E00034504 optional module allows non-intrinsically safe coupling to PROFIBUS-PA. The A5E00019145 optional module allows coupling to PROFIBUS-DP. Note Explosion protection The A5E00015899 Exi optional module is an associated piece of equipment and may only be fitted in the ULTRAMAT 6 F / OXYMAT 6 F / CALOMAT 6 F devices with protection type EExp[ia/ib] IIC T4. ULTRAMAT 6 / OXYMAT 61 CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 76 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 EFTA01216647 2 Assembly Information 2.1. Bus Connection for ULTRAMAT / OXYMAT / CALOMAT 6 in Field Housing Cassette front 37-pin Sub-D socket for additional binary inputs and relay outputs: as autocal option Warning 9-pin Sub-D socket connector PROFIBUS-DP connection 9-pin Sub-D plug connector PROFIBUS-PA connection (Exi or not Exi ) Connections on bottom Field mounted analyzers with PROFIBUS connection, which are used in potentially explosive areas, must only use the board A5E000 15899 Exi The I/O's of the 37 pin Sub-D socket must be connnected and operated only with special protection (see operating manuals OXYMAT 6 / ULTRAMAT 6 / CALOMAT 6) The relevant regulations for installation and operation of electrical systems must be observed. ULTRAMAT 6 / OXYMAT 6/CALOMAT 6/ ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 77 EFTA01216648 2.2 Bus Connection for ULTRAMAT / OXYMAT / CALOMAT 6 Module and OXYMAT 61 C C Only with ULTRAMAT/OXYMAT or ULTRAMAT 6 E two-channel device Rear of device 9-pin Sub-D socket connector PROFIBUS-DP connection 9-pin Sub-D plug connector PROFIBUS-PA connection (not Exi ) 37-pin Sub-D socket for additional binary inputs and relay outputs: as autocal option ULTRAMAT 61 OXYMAT 6/ CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 78 Schnittstelle PROFIBUS DP i PA Interface A5E00054148.03 EFTA01216649 2.3 Bus Connection for ULTRAMAT 23 X90 X50 Rear of device 9-pin Sub-D socket connector PROFIBUS-DP connection 9-pin Sub-D plug connector PROFIBUS-PA connection ( not Exi ) 37-pin Sub-D socket for additional binary inputs and relay outputs: as autocal option ULTRAMAT 6 f OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 f OXYMAT 61 79 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216650 2.4 PROFIBUS-PA Bus Connectors The 9-pin Sub-D female connector enclosed with the device/option is required. The bus cable can be connected with a solder joint. Connectors with removable terminal connections are available, for example, from Company: Phoenix Contact Type: SUBCON 9/F-SH Item no.: 27 61 49 9 2.4.1 Pin Assignment PROFIBUS-PA Bus Connector Function PIN PA-P(+) 3 PA-N ( - ) 7,8 NC (Not connected) 1,2,4,5,6,9 2.4.2 PROFIBUS-PA Cable SIEMENS - order number: (cables for FastConnect technique) 6XV1 830-5CH10 (blue) for applications in hazardous areas 6XV1 830-5DH10 (black) for applications in non-hazardous areas Note The cable screen should be connected fully in the connector housing. ULTRAMAT 6 OXYMAT 6/ CALOMAT 61 ULTRAMAT 23 OXYMAT 61 80 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216651 2.5 PROFIBUS-DP Bus Connectors The 9-pin Sub-D male connector (plug connector) enclosed with the device/option is required. The bus cable can be connected with a solder joint. Connectors with removable terminal connections are available, for example, from Company: Phoenix Contact Type: SUBCON 9/M-SH Item no.: 27 61 50 9 Ir Note This connector does not have any integrated bus terminators. Other RS 485 bus connectors are suitable for the PROFIBUS-DP. SIEMENS - order data: (examples) 6GK1 500-OEA02 6ES7 972-0BA11 - OXAO 6ES7 972-0BA40 - OXAO 6ES7 972-0BA50- OXAO Note axial outgoing cable unit, internal modular terminals 90° outgoing cable unit, internal modular terminals angled outgoing cable unit, internal modular terminals 90° outgoing cable unit, insulation piercing connecting devices for FastConnect cables The connector with the axial outgoing cable unit should be used when PROFIBUS-DP and binary inputs/relay outputs are connected. ULTRAMAT 6 OXYMAT 6/ CALOMAT 61 ULTRAMAT 23 OXYMAT 61 81 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216652 2.5.1 Pin Assignment of PROFIBUS-DP Bus Connector Function PIN RxD/TxD-P 3 Data line B CNTR-P 4 Direction control DGND 5 Data transmission potential (ground to 5V) VP 6 +5V for bus terminators, optical link plug RxD/TxD-N 7,8 Data line A NC Not used CC Note Pin 7 is connected to the data line. Consumers must not be connected to this pin. 2.5.2 PROFIBUS-DP Cable SIEMENS - order data: (example) 6XV1 830-0E10 (violet) also for FastConnect technique Air Note The cable screen should be connected fully in the connector housing. 1,2,9 ULTRAMAT 6 / OXYMAT 6/CALOMAT 6/ ULTRAMAT 23 / OXYMAT 61 82 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 EFTA01216653 2.6 Pin Assignment on Binary and Relay Outputs 2.6.1 ULTRAMAT 6 E / OXYMAT 6 E / CALOMAT 6 E / OXYMAT 61 Pin Assignment You will find a detailed description in the respective device manual (chapter 2). DSUB 37F I I I I Function in I PIN I Function I Comments device M , 1 I 2 3 4 5 5 7 8 9 10 11 12 13 18 M 19 1 GND 20 Relay 7 Contact loading: 21 max. 24 V / 1A, AC/DC 22 Relay 8 23 Relay is dead for relay contact setting shown 24 Relay 9 25 Relay 10 26 27 Relay 11 28 Relay 12 29 30 Relay 13 31 Relay 14 32 Digital input 7...14 - N 33 Digital input 7 Digital input 8 - P Potential-free via optocoupler 34 Digital input 9 - P Digital input 10 - P "0" = O V (0..A,5V) 35 Digital input 11 - P Digital input 12 - P "1" = 24 V ( 13...33V ) 36 Digital input 13 - P Digital input 14 - P 37 NC (not connected) NC (not connected) I GND ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 83 EFTA01216654 2.6.2 ULTRAMAT 23 Pin Assignment You will find a detailed description in the respective device manual (chapter 3). DSUB 37F Function in device M PIN 2 3 4 5 5 7 8 9 10 11 12 13 18 M _19 Function Comments GND 20 Relay 9 Contact loading: 21 max. 24 V 11A, AC/DC 22 Relay 10 23 Relay is dead for relay contact setting shown 24 Relay 11 25 Relay 12 26 27 Relay 13 28 Relay 14 29 30 Relay 15 31 Relay 16 32 Digital input 1...8 - N Digital input 1 - P Potential-free 33 Digital input 2 - P via optocoupler Digital input 3 - P 34 Digital input 4 - P "0" = O V (0..A,5V) 35 Digital input 5 - P "1" = 24 V ( 13...33V ) Digital input 6 - P 36 Digital input 7 - P Digital input 8 - P 37 NC (not connected) NC (not connected) GND ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216655 2.6.3 ULTRAMAT 6 F / OXYMAT 6 F CALOMAT 6 F Pin Assignment You will find a detailed description in the respective device manual (chapter 2). Terminal block Function in device M PIN 3 5 7 9 11 13 15 17 19 21 23 25 35 M 37 Function GND Comments 2 [Contact Relay 7 loading: 4 max. 24 V 11A, AC/DC 6 Relay 8 8 Relay is dead for relay contact setting shown 10 Relay 9 12 Relay 10 14 16 Relay 11 18 Relay 12 20 22 Relay 13 24 Relay 14 26 Digital input 7...14 - N Digital input 7 - P Potential-free 28 Digital input 8 - P via optocoupler Digital input 9 - P 30 Digital input 10 - P "0" = 0 V (0..A,5V) 32 Digital input 11 - P "1" = 24 V ( 13...33V ) Digital input 12 - P 34 Digital input 13 - P Digital input 14 - P 36 NC (not connected) NC (not connected) GND ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 85 EFTA01216656 2.7 Optional Module Setup Flash EEPROM _- firmware MOO _MO A5E00019145 / A5E00034504/ A5E00015899 (Exi) 26-pin ribbon cable connector to motherboard Binary inputs/relay outputs 37-pin Sub-D socket PROFIBUS-PA 9-pin Sub-D socket N PROFIBUS-DP 9-pin Sub-D plug 2.8 Installing the Optional Module (Retrofitting) lir Note The firmware in the analyzer may need to be changed. See chapter 6.2 Firmware Note With module devices only the A5E00034504 module can be installed for non-intrinsically safe connection to PROFIBUS-PA and the A5E00019145 module for connection to the PROFIBUS-DP. ULTRAMAT 6 / OXYDAAT 6 / CALODAAT 6 / ULTRAMAT 23 / OXYMAT 61 86 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216657 2.8.1 Installing the Optional ULTRAMAT / OXYMAT 6 / CALOMAT 6 Module and OXYMAT 61 lir Note 2 PROFIBUS interfaces are required for the ULTRAMAT/OXYMAT or ULTRAMAT 6 E two channel device. Installation instructions: Disconnect the device from the mains Unscrew and remove the housing cover Remove the old optional module if installed Fit the module(s) into the rail on the base Fasten the module(s) with the M3 screws to the rear panel between connectors Connect the connectors to the motherboard Fit the clamping bar Screw on housing cover Connect the device to the PROFIBUS Connect the device to the mains Optional modules Motherboard channel 1 Motherboard channel 2 Rear panel ULTRAMAT 6 f OXYMAT 6/ CALOMAT 6 1 ULTRAMAT 23 f OXYMAT 61 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 Fig. 2.1 87 EFTA01216658 2.8.2 Installing the Optional ULTRAMAT / OXYMAT / CALOMAT 6 Field Housing Module lir Note The A5E00015899 Exi module for intrinsically safe connection to the PROFIBUS-PA may only be installed in Exp[ia/i13] field housing devices. With all other non-Ex devices only the A5E00034504 for non-intrinsically safe connection to PROFIBUS-PA or the A5E00019145 module for connection to the PROFIBUS-DP can be installed. Installation instructions: Disconnect the device from the mains Open the left-hand housing door Remove the sheet metal cover Remove the sheet metal cassette from the device Remove the old optional module if installed Fit the module in the rail Fasten the module with the M3 screws to the underside of the cassette between connectors Fit the bracket on the top edge of the optional module Connect the connectors to the motherboard Fit the sheet metal cassette in the device Connect the 37 Sub-D-connector with the terminal block Replace sheet metal cover Connect the device to the PROFIBUS Connect the device to the mains Motherboard Optional module r ULTRAMAT 6 f OXYMAT 6/ CALOMAT 6 1 ULTRAMAT 23 f OXYMAT 61 Schnittstelle PROFIBUS DP i PA Interface A5E00054148.03 r Cassette Connect 26-pin ribbon cable Fig. 2.2 88 EFTA01216659 2.8.3 Installing the ULTRAMAT 23 Optional Module oir Note With the ULTRAMAT 23 only the A5E00034504 module can be installed for non-intrinsically safe connection to PROFIBUS-PA and the A5E00019145 module for connection to the PROFIBUS-DP. Disconnect the device from the mains Unscrew and remove the housing cover Remove the old optional module if installed Fasten the module with the M3 screws to the rear panel between connectors Fasten the module to the housing base with plastic bolt (included in add-on kit). Connect the connectors to the motherboard Screw on housing cover Connect the device to the PROFIBUS Connect the device to the mains Rear panel I I oaunuuaaa Optional module Motherboard Fastening bolt Connect 26-pin ribbon cable Fig. 2.3 ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 89 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216660 3. Transmitting User Data via PROFIBUS Data structures, their meaning and functions are set in the "PROFIBUS-PA Profiles" for the PROFIBUS-PA. The profiles are specified in the following documents: PROFIBUS-PA Profile for Process Control Devices / General Requirements PROFIBUS-PA Profile for Process Control Devices / Mapping to Fieldbus PROFIBUS-PA Profile for Process Control Devices / Data Sheet Transmitter PROFIBUS-PA Profile for Process Control Devices / Data Sheet Analyser PROFIBUS-PA Profile for Process Control Devices / Data Sheet Discrete Output Available on the Internet at or from: PROFIBUS Nutzerorganisation Haid-und-Neu-Str. 7 D-76131 Karlsruhe Tel.: +49 721 / 96 58 590 Fax: +49 721 / 96 58 589 ULTRAMAT 6 f OXYMAT 6/ CALOMAT 6/ ULTRAMAT 23 f OXYMAT 61 90 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 EFTA01216661 3.1. Profiles for ULTRAMAT, OXYMAT and CALOMAT Bock model for PROFIBUS-PA ULTRAMAT, OXYMAT or CALOMAT PROFIBUS PA Option. Device Physical Block Measured Transducer value Block cess Function Block Analog Input Measured value = input value Output value PROFIBUS PA / Block structure of a gas analyzer with 4 block types, example for one measured value. ullr Note The complete table of objects you will find in appendix chapter 7.5 Variants Transducer Blocks Function Blocks TB Al ( Analog Input ) DO ( Digital Output ) ULTRAMAT 6 with 1 component 1 1 1 ULTRAMAT 6 with 2 components 2 2 1 ULTRAMAT 23 with 1 component 1 1 1 ULTRAMAT 23 with 2 components ') 2 2 1 ULTRAMAT 23 with 3 components ') 3 3 1 ULTRAMAT 23 with 4 components ') 4 4 1 OXYMAT 6 1 1 1 CALOMAT 6 1 1 1 OXYMAT 61 1 1 1 On ULTRAMAT 6 and ULTRAMAT 23 the assignments to the infrared (IR) measuring components always start with "1" in ascending order. ULTRAMAT 6 / OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 OXYMAT 61 Schnittstelle PROFIBUS DP 1 PA Interface A5E00054148.03 91 EFTA01216662 On ULTRAMAT 23 there are the following possibilities due to the O2 measuring components (sensor): Variants IR measuring component 1 IR measuring component 2 IR measuring component 3 O2 lit spoils:e) 7MB 2331 TB/Al 1 7MB 2333 TB/Al 1 TB/Al 2 7MB 2334 TB/Al 1 TB/Al 2 TB/Al 3 TB/Al 4 The corresponding gas for the measuring components is indicated by the device MLFB number (see rating plate). 3.1.1 Transducer Block with ULTRAMAT, OXYMAT and CALOMAT The analyzer transducer block receives its input value from the ULTRAMAT, OXYMAT and CALOMAT basic unit. This causes the device-related functions of sensors as well as the measured-value acquisition and processing to be separate from the function block. Rel. Index Parameter Description 8 COMPONENT_NAME Name of the component 9 PV Measured value which is forwarded to the Al block 10 PV_UNIT Measured value unit 11 PV_UNIT_TEXT Unit in text form 12 ACTIVE RANGE Current measuring range/always "1". ULTRAMAT, OXYMAT and CALOMAT use the largest measuring range here (characteristic curve upper value) 13 AUTORANGE_ON Automatic measuring range switchover TRUE/FALSE No significance as ULTRAMAT, OXYMAT and CALOMAT always use the largest measuring range (characteristic curve upper value). 14 SAMPLING_RATE Time between two measured value readings 25 NUMBER_OF_RANGES Number of measuring ranges/always just one measuring range 26 FtANGE_1 Measuring range lower and upper value ('largest measuring range') 34 POSITIONING_VALUE Value (11:ffiS for triggering autocalibration. Taken from DO block ( ). 35 FEEDBACK Value (1 byte) for feedback on the autocalibration status (taken from DO block FEEDBACK). ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 92 EFTA01216663 3.1.2 Analog Input Block with ULTRAMAT, OXYMAT and CALOMAT The measured value and status for the process is provided via the analog input block. Rel. Index Parameter Description 10 OUT Output value and status. Result of the analog input function block 11 PV_SCALE Input scale. As a rule the measuring range of the transducer block. The lowest value (0%) is represented by 0, the top value (100%) by 1. 12 OUT_SCALE Output scale. Representation of user-specific physical size. The lowest value (0%) is represented by 0, the top value (100 %) by 1. Indication of user-specific unit. 13 LIN_TYPE Selection of curve shape for characteristic curve transformation. 16 PV_FTIME Filter time constant r of digital filter 1st order. 17 FSAFE_ TYPE Parameterization of safe position. Active only in AUTO mode if the measured or simulation value has a bad status (BAD) or the current mode O/S is active. 0: The default value FSAFE_VALUE is used for the safe position. The status raised to uncertain — substitute set. 1: The output value last valid before the failure will still be used. The status is raised to uncertain — last usable value. If there was no valid value before, the initial value will be returned with the uncertain — initial value status. 2: The value will be used for further calculation despite the bad status. If this parameter is not implemented, the Al will behave as described in • 1. 18 FSAFE_VALUE Default value for safe position. 19 ALARM_HYS Limit value hysteresis. For avoiding an alarm surge or waving of signal flags. After a limit value has been exceeded the value must have moved the hysteresis in the opposite direction before the limit value signal is reset. 21 HI_HI_LIM Upper alarm limit 23 HI_LIM Upper prewarning limit 25 LO_LIM Lower prewarning limit 27 LO_LO_LIM Lower alarm limit 30 HI_HI_ALM Alarm status parameter for upper alarm limit. 31 HI_ALM Alarm status parameter for upper prewaming limit. 32 LO_ALM Alarm status parameter for lower prewaming limit. 33 LO_LO_ALM Alarm status parameter for lower alarm limit. 34 SIMULATE Simulation value and status, enabling of simulation. 35 OUT_UNIT_TEXT ASCII text to be stored if the unit "text reference' is indicated in OUT SCALE. ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 93 EFTA01216664 3.1.3 Cyclical data transmission/measured value status The following user data can be exchanged cyclically using the PROFIBUS: Parameter name Meaning Direction seen from gas analyzer Data type Length in bytes OUT Measured value and status Output DS-33 5 DS 33 data type: See PROFIBUS-PA Profile for Process Control Devices / General Requirements for a detailed description Byte 1 Byte 2 I Byte 3 Byte 4 Byte 5 Analog value in IEEE floatin point Status Exponent Fraction MSB Meaning of Status A status byte is transmitted synchronously in addition to each of the measured values in the DS-33 data structure. This byte provides indication of the quality for this value in a "quality code. The status byte has the following structure: See PROFIBUS-PA Profile for Process Control Devices / General Requirements for a detailed description MSB 7 6 5 4 3 2 1 0 Quality Substatus Limits 0 0 bad bad 0 1 uncertain uncertain 1 0 good 1 1 good (cascaded) _good good (cascaded) The substatus has a different quality depending on the coding 0 0 ok 0 1 low limited limit value undershot 1 0 high limited limit value exceeded 1 1 constant value constant ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 94 EFTA01216665 Status coding for ULTRAMAT/OXYMAT/CALOMAT: Status coding for "bad quality" Dec Hex Cause Remedy 11 0B Component missing Change configuration, install analyser including this component 12 0C Device error Check with SIMATIC PDM / change analyzer 31 1F Out of order (equivalent value, last valid value, through conned value) Depending on the paramterization. Switch in mode AUTO Status coding for "uncertain quality" Dec Hex Cause Remedy 64 40 Function control Warm up, AUTOCAL, in situ service 71 47 Measured value is bad, last valid value Check with SIMATIC PDM / change analyzer 75 4B Measured value is bad, equivalent value Check with SIMATIC PDM / change analyzer 79 4F After switching on the power, initial value Reject the measured value 80 50 Measured value is out of range Check with SIMATIC PDM / ambient temperature too high Status coding for "good quality" Dec Hex Cause Remedy 128 80 o.k., normal operation You can evaluate the measured values 132 84 Active block alarm, parameter has been changed Disappears after 10 seconds 137 89 Lower warning limit exceeded user programm 138 8A Upper warning limit exceeded user programm 141 8D Lower alarm limit exceeded user programm 142 8E Upper alarm limit exceeded user programm 164 A4 Maintenance request Check with SIMATIC PDM ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 95 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216666 3.1.4 Discrete Output Block with ULTRAMAT, OXYMAT and CALOMAT The input value from the discrete output function block in the AUTO mode is the setpoint which is transferred as a cyclical use date for triggering AUTOCAL using the PROFIBUS of the optional module. Rel. Index Parameter Description 9 Transfer value/digital value in the AUTO mode 10 Calculated output value of the discrete output function block. 19 FSAFE_TIME Monitoring time in seconds. The failsafe control monitors the bus communication, in particular the setpoints and RCAS IN. 12 The readback value contains the current state in the device (actual value). 20 FSAFE_TYPE Defines the reaction of the device if the used setpoint is still bad after the monitoring time FSAVE_TIME has expired. One of three reactions can be set: 0: The substitute value becomes effective. 1: The last valid set value is still issued. The value has the 'Uncertain, last valid value status. 21 Substitute value in failure behavior and when reaction type FSAFE TYPE = 0 is set. 24 SIMULATE Simulation value and status for the actual value, enabling of simulation. 33 CHECK_BACK not used 34 CHECK_BACK_MASK not used ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 96 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216667 3.1.5 User Data Discrete Output Block with ULTRAMAT / OXYMAT I CALOMAT The following user data can be transmitted cyclically to the device using the PROFIBUS. Parameter name Meaning Direction seen from gas analyzer Data type Length in bytes Setpoint of function block used in Mode AUTO Input DS-34 2 Readback of function block Output DS-34 2 DS 34 data type: See PROFIBUS-PA Profile for Process Control Devices / Data Sheet Discrete Output for a detailed description Byte 1 Byte 2 Digital value/setpoint Status Meaning of the bits in with ULTRAMAT/OXYMAT/CALOMAT (trigger autocal) MSB LSB B08 807 B06 B05 804 803 802 801 Meaning -- -- 1: Cancel autocal if active B01 can then be 1 or 0 1: Trigger autocal 0: no function Meaning of the bits in with ULTRAMAT/OXYMAT/CALOMAT (acknowledge autoca ) MSB LSB B08 B07 B06 B05 B04 B03 802 801 Meaning 1: Autocal functioning 0: Autocal not functioning See chapter 3.1.3 "Meaning of status" for the meaning of the status bytes ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 1 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148.03 97 EFTA01216668 3.1.6 Physical Block with ULTRAMAT, OXYMAT and CALOMAT Device-specific properties can be displayed/set using parameters in the physical block. Rel. Index Parameter Description 8 SOFTWARE_REVISION Firmware version of the device 9 HARDWARE_REVISION Hardware version of the device 10 DEVICE_MAN_ID Manufacturers code SIEMENS AG = 42 11 DEVICE_ID Manufacturers identification: e.g. ULTRAMAT 23 12 DEVICE_SER_Num Serial number of the device 13 DIAGNOSIS Bit encoded standard diagnostic messages 15 DIAGNOSIS_MASK Bit mask indicating which DIAGNOSIS bits are supported. 17 DEVICE_CERTIFICATION Details about certification in plain text 18 WRITE_LOCKING Write protection function. Write access is refused with the error code access denied. 19 FACTORY_RESET Command to trigger reset functions in the device: • 0: No action. • 1: Reset all parameters to the factory settings. Except for the set station address, the IDENT_NUMBER parameter and the ST REV. The device shows the following cold start in the corresponding bit of DIAGNOSIS for 10 sec. • 2506: Initiate a device warm start. The device shows the following cold start in the corresponding bit of DIAGNOSIS for 10 sec. • 2712: Reset the station address to the normal PROFIBUS default address 126. 20 DESCRIPTOR Option to store a description of the device within an application. 21 DEVICE_MESSAGE Option to store a message about the device within an application. 22 DEVICE_INSTAL_DATE Installation date of the device 23 LOCAL_OP_ENA Enable local operation 24 IDENT_NUMBER Each PROFIBUS device must check an identification number issued by the PNO in the Configuration Phase. The user sets the configuration behavior of the device here: • 0: Only the PROFILE identification number is acknowledged positively. • 1: Only the device-specific identification number is acknowledged positively. 36 DEVICE_CONFIGURATION Description of the device configuration ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 98 EFTA01216669 Rel. Index Parameter Description 37 INIT_STATE When a reset action is carried out, the device switches to a state in which parameters can be set after running through a device-specific initialization phase. Either one of the device states or also the state before reset can be selected as an initialization phase. 1: State before reset 2: Run 3: Standby 4: Power down 5: Maintenance 38 DEVICE_STATE Four statuses are defined which rule each other out: 2: Run: All equipment required to generate valid measured values is active. 3: Standby:The device is ready for measuring or can switch to the run state without a delay using a command. 4: Power down: Economy or power-down mode. The unit is not ready for measurements. It may take a long time to reach readiness for measurement. 5: Maintenance: Behavior depends on device. A new state is selected by writing the desired state (code) in the DEVICE_STATE parameter. The global device status is the top hierarchy level of the status information. It indicates whether there is an active message in one of the status classes named below. Each bit of the global status is the or link of all bits from the corresponding status class. Bit 0: Failure Bit 1: Maintenance required Bit 2: Function check Bit 3: Limits (limit violations recognized in transducer and/or function block) Bit 4-15: Manufacturer-specific Specific for SIEMENS Gas analyzers 50 CALIBRATION_DATA Date of the last calibration. Name of the person who has calibrated the analyzer. 51 PRODUCT_CODE MLFB-(order-) Number 52 ERRORS Faults 53 WARNINGS Maintenance requests See also PROFIBUS-PA Profile for Process Control Devices / Data Sheet Analyser and General Requirements for description ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 99 EFTA01216670 Diagnosis The diagnostic messages can be made visible online with the aid of a tool, e.g. SIMATIC HW config under the "Module Status" menu item. Standard PROFIBUS-DP mechanisms are used to transport diagnosis information and signaled actively to the class 1-Master. The DIAGNOSIS parameter from the Physical Block is then available to the master as diagnostic information. The device states are displayed on the PROFIBUS-PA physical block DIAGNOSIS bits. The diagnostic messages can be made visible online in the module status with the aid of a tool, e.g. SIMATIC HW config. It is also possible to read out the DIAGNOSIS parameter using SIMATIC PDM. A detailed list can be found in the appendix, chapter 7.4 Diagnosis. 3.1.7 Specific parameters physical block Specific parameters in physical Block for SIEMENS Gas-analyzer Type Number 50 CALIBRATION_DATA record 2 Date octet string 8 Who visible string 24 51 PRODUCT_CODE visible string 32 52 ERRORS octet string 4 53 WARNINGS octet string 2 ULTRAMAT 6 I OXYMAT 61 CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 100 Schnittstelle PROFIBUS DP I PA Interface A5E00054148.03 EFTA01216671 Faults of ULTRAMAT / OXYMAT / CALOMAT are defined in the parameter ERRORS: S1 ...532 see chapter 7.4 Diagnosis . Bvte 0 Bit 8 7 6 5 4 3 2 1 Fault S8 S7 S6 S5 S4 S3 S2 S1 Byte 1 Bit 8 7 6 5 4 3 2 1 Fault S16 S15 S14 S13 S12 S11 S10 S9 Bvte 2 Bit 8 7 6 5 4 3 2 1 Fault S24 S23 S22 S21 S20 S19 S18 S17 Byte 3 Bit 8 7 6 5 4 3 2 1 Fault S32 S31 S30 S29 S28 S27 S26 S25 Maintenance requests of ULTRAMAT / OXYMAT / CALOMAT are defined in the parameter WARNINGS: W1 ...S16 see chapter 7.4 Diagnosis. Byte Bit 8 7 6 5 4 3 2 1 Maint. requ.. W8 W7 W6 W5 W4 W3 W2 W1 Byte 1 Bit 8 7 6 5 4 3 2 1 Maint. requ.. W16 W15 W14 W13 W12 W11 W10 W9 ULTRAMAT 6 / OXYDAAT 6 / CALODAAT 6 / ULTRAMAT 23 / OXYMAT 61 101 Schnittstelle PROFIBUS DP / PA Interface ME00064148-03 EFTA01216672 4 Commissioning Functions/Operation using PROFIBUS-PA After installation and bus configuration, setting of the station address (see chapter 5 Operation) the system can be configured with the corresponding tools. The current firmware version of the devices should be checked with retrofitting, see chapter 6.2: Firmware A PC software such as SIMATIC PDM must be used for operation using PROFIBUS-PA. Operation is described in the appropriate instruction manuals and online helps which you should consult. At the moment PROFIBUS-PA communication only provides access to a limited scope of functions for the ULTRAMAT / OXYMAT / CALOMAT gas analyzer. 4.1 Selection of Devices with a Configuring Tool Selection of the ULTRAMAT / OXYMAT / CALOMAT gas analyzers is to be explained with STEP 7, HW-Config as an example. ULTRAMAT 6 OXYMAT 61 CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 102 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216673 4.1.1 Selection of the Nominal Configuration Mh miaLl 6 Was L111 1e1e1 (SD Ya onan Yoked d1 Dioi2-ig 'IN i t el alai Art V El is 107 PA 3 X4161 PPACALew MPIILDP CPIUSEa 5 CP 54.3-1 7 8 moneusi ce ni t/L1 LLaccpoLl u. I A.Am• I • 7 lur LAT RAMAT 21 2 “roowisl U.TRAK41,1313554/xont1 U. POMO 2314 cercomnIM DNA; 6 4 T ROAM/Sy nrAtnyme44159321 St:usual trJricoa a `' PROPOUS/81 PNmsee roam 54311 t it70L4t irA0A1 vol it t u18n in k owl 1:1 U152 SU 1 di Moak PS407104 Chda onto I MPS palm US740700.0101•40 lobe» Oa:4w Cornea A? CPU 4163 DP 1557 414-35202 04110 3 Mao 40111P inv . lamalknoatials e.+. IDA-Dad m5,71855 DP 011806 PA • II-1 Aare, • —I O, A I WOO • _J Sgasno • _J Caws J 5aLLas • __I rott - -J DanAD.Maa . No43 - J So Se J SEW(55 •aL Dom/ 6 unm•mlnu - Wain g Urramel nada Oboe. 6 ra-mml prom • —1 tma J to Admias AL Li ARCO! tomeabe 511445C .413 • II 9444)4c 40) SIWOLC PC BeLDICGIOM10 • a StworC PC Slacn frirt4MAt 23 polo me Am moo& The instruments concerned have either a DP or a PA interface. Select the appropriate instrument from the DP or PA catalog. ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 OXYMAT 61 103 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216674 4.1.2 PROFIBUS Address lexn tot own DC yow &we yinfc. Edo 1,61 I Skil Mirel J LI? Innkncentb CPU 4164 ciRiCate PAO, CP WA Ge-gge PseRnen 6 1,01/tILII °Prong PRC B [Pm :. a HIM 15>I inn( ; CPU 416-2 DP US? 41CrZRO2-0ABO IR ALA.'S' .2.1±;1 3 11100BUS OP PA 0 Re USN . J kirks, • _I Caolip 0/01 • _I 13 &Moro . J Ctle - ,J Serum R RR. - Go PR*. . Rd.* 3 Sa - J LCM(xs Le g u. n ...••••••.;:u - j Ursa I UhesiR 6 C.-) Cwel ;:j Wad Anftm ;€ CJ Aunt C) rewcoOkot stwoic 100 51140C 101 . A WARE PC Bica CRIS 30V10 • A 9544TIC PC SLR*, mean la re web.. Iwa You set the PROFIBUS address here. ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 OXYMAT 61 104 Schnittstelle PROFIBUS DP J PA Interface A5E00054148.03 EFTA01216675 4.1.3 Function Blocks MI ES ',nil Etc Ys.. Dprov W.Va. be Itl g Rol idol Miff J Lk i1 1.1..C.1 Fii.,; ;) it 0 AI., ii .ILIela S......fe i COMO iutiPaaT A> Ser• Irt 0t nob. I mfr.,. Onsrannt. IRS &V 0 ma,. ICentren k .. .LI AnAnn • ,L.) Pinta Cj 101Ctithat Siwait -' SIMMS) - %SICK Bosedeceb:4)UV 40 - a SWAM ft Su•kn basitn tate ...en.. sa• enabled IMMOT Here you can check the number of blocks and the address assignment. ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 105 Schnittstelle PROFIBUS DP f PA Interface A5E00054148.03 EFTA01216676 4.1.4 SIMATIC PDM Instrument Catalog 015 Of Ron Ea Sol BC Y« 40*. olcsli-la It, g Mel Mel alrig g Rz anoneusni DP•telw open III PA0ew..C•slatase II saw narAcal - C.9 MaSen - SIMMS O 11.1RAWU VII IR IN lt1RAMAT 1321R crarrosi•T 2.azin 01 ULTRalla 23 3IR 13LIPHN12331P 02 9 Mout 6 ULIRMA161111 IATIWIAT6 in ULTRYIAT (94••••• ',ULM% aIft 1 in ill , ' JO: Dell• I 99a: FLODliBuS DP FROFIBUSPA • J lcusa• • J Deasy-on °Swam • J Ong - 599t. 09. - J Gukviret PK:MI • _j - IONS - rot; wad w mins 23 Untativ4.• Uhow 3 I wen Cite". CjiWiAMOttg rj Rena 9 al Itiscohn • ■ SitiAtIC X0 • 5 9%40[40 • 5 SINATIC PC Bard Cenci Win SIRATIC FC 9an f e.ece oreSe N. gee an:6w OXellAT C You can select the appropriate instrument after double clicking the new instruments icon. ULTRAMAT 6 OXYMAT 6/ CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 106 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216677 4.1.5 Starting SIMATIC PDM r SiMATH: VON N I poses Pe Rene Yre• CNN« Bob !di le All LI a S/I kleohcartn CleautonUert 6 Devoe S war Nearavel I F6 0,41M El AnokolowiFutrantlke O Barchirdrawan 6 Room vet» rule CI Odowt rule O Ogee bit FallSetel1/2 1e O Humenheidem coetikenirdkuceds Pens Fl lor lob Param et Siemens Anahiter • Identifitadon • • Operation Unit TAG DescruOr Message • • Device SIMS Renames No Manthreturer PicerN designation Dance Confrjuratron Ordemumbetr Senal Number Software Ronson Honftware Damien %Q. Peewee PROFEIUS Ideal Plumber Installation Dale Irdearaten Stele Lan calturalen Exectter • lope • • Wooed 1 Ion No aine Unit Stat PIT positon i t Maim. Message Siemens Siemens Analyzer Option PROMS 7IA32 143001 D O 0 3D NanuteCtuNet ipecac 101 012000 I Slates twin Reset 4 N AMU Itiame nitial value altial value altial value &del value nitwit value /SUM value &tint value aidai value aida) value altiat value aidai value nlual value aidai value aidai value Meal value &del value Una SUftrtiaft Rite Lower Value Upper Value • Mean • • Amulet Input Funds» Sock 1 SINN Redskin No. Und Component 1 !WM 1000 rr ; %,01 nluat value 'tidal value nine value aidai value nidal value Moat value d%vol Initial value Initial value .-:•-:‘,0 N.) cc• re:i nog You can start SIMATIC PDM after making your selection. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 I OXYMAT 61 107 Schnittstelle PROFIBUS DP PA Interface A5E00054148-03 EFTA01216678 4.2 Settings ULTRAMAT OXYMAT and CALOMAT are capable of mastering a large number of measuring tasks. To do this you have to make the following settings: Settings with SIMATIC PDM: Here you set the parameters which also have an influence on the cyclic useful data. When you select the appropriate instrument according to the type and number of components, you get the appropriate default settings in the SIMATIC PDM user interface. The following sections only contain those which you need to set additionally. 4.2.1 Selecting the Gas Analyzer / Transducer Block Measuring Variable Create a suitable instrument. The measuring range cannot be changed in the measuring variable block. The maximum measuring range is always displayed here. The unit can be switched between vpm and mg/m3 in some analyzers. The 'Analog Input Block' takes over the necessary input range from the 'Measuring Variable' transducer block. The output range must be parameterized according to the requirements in the Analog Input Block. The name of the component can be changed in the transducer block and is used in the measured value display image in the measured values/input tab. The frequency of the measured value refreshment can be set with the scanning interval. 4.2.2 Analog Input Block / TAG The name of the process measuring variable can be changed as a "TAG". This name is shown in the measured value display in the measured values/output tab to identify the measured value. 4.2.3 Autocal If the appropriate option is available, the analyzers can perform a full calibration cycle. This calibration can be started in the Instrument/Autocal menu. ULTRAMAT 6 OXYMAT 6 / CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 108 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216679 4.2.4 Adapting to the Desired Process Variable The 'Analog Input' function block has the job of projecting the measured value onto the process value. As a rule you want to switch the measured value directly to the bus. In this case the input and output ranges are taken over from the working range. The measured concentration can be adapted to the process variable here. Transfer the start of scale and full scale values of the input range to the start of scale and full scale values of the corresponding output range as described in the following examples: ga::, Note: In the Analog Input function block there is no access to the instrument via PROFIBUS-PA. The input can only be evaluated here by using SIMATIC PDM. Example: You want to assign the input range 0 to 1000 mg/m3 CO to the output range 0 to 100 %. Proceed as follows: Set the following parameters: In the 'Measuring variable 1' block: CO as a measuring component as well as as a unit of the primary variable: mg/m3 In the 'Analog Input 1' function block: as an input start of scale value: 0 as an input full scale value: 1000 as a unit (output): % as an output start of scale value: as an output full scale value 100.0 0.0 4.2.5 Electrical Damping The electrical damping acts as a 14' order filter. After the preset filter time constant Te3 the output has 63 % of the input value. Set the desired time (between 0 and 100 s) as a filter time constant parameter in the Analog Input function block. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 231 OXYMAT 61 109 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216680 4.2.6 Warning and Alarm Limits The function blocks of the analog input have upper and lower warning and alarm limits for the output. To avoid unstable display of the warnings and alarms, you can specify a hysteresis. Set the following parameters according to the process conditions in the analog input function blocks: • Hysteresis limit value • Upper warning limit • Upper alarm limit • Lower warning limit • Lower alarm limit On exceeding the limits, the output is accompanied by a status value which you can evaluate in your application program. The following figure shows an overview of the individual limit values. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 OXYMAT 61 110 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216681 4.2.7 Failure Behavior The analog input function blocks can adopt a preset behavior in the event that the measuring block fails. If the output variables of the measuring block are accompanied by a -bad" status due to an error, e.g. -Bad — Sensor fault", the function blocks activate the failure behavior. The output is then accompanied by an -unsure- status. You will find an overview of the status' in section 3.1.3. Set the failure behavior in the analog input function block. Failure behavior Description The equivalent value is transferred to the output value The predefined safety default is output Save the last valid output value The last valid output value is output The incorrect calculated measured value is available at the output (failure logic switched off) The bad output value is accompanied by the status assigned to it by the measuring block 4.2.8 Simulations Simulation functions help you to commission plant parts and analyzers. You can generate process values without entering real measured values. The value range of the simulated process values can be fully exploited. It is therefore also possible to simulate errors. 4.2.8.1 Simulation of the Output You can provide process values for the cyclic useful data traffic at the output of the ULTRAMAT/OXYMAT/CALOMAT with non-cyclic write accesses. In this way you can check the process value processing in the automation program. Proceed as follows: Select simulation of the output Set the target mode to MAN (manual) Enter the desired output value, the quality and the status Transfer the settings from the program to the transducer. The behavior of the output can be observed for example in SIMATIC PDM or a variable table (VAT- component). Set the target mode to AUTO to retum to normal operation. ULTRAMAT 6 I OXYMAT 6 / CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 111 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216682 4.2.8.2 Simulation of the Input With simulation of the input you can check the adaptation of the measured value to the desired process variable, monitoring of your preset process limits, the electrical damping and the failure behavior. Proceed as follows to do this: • Select simulation of the input • Set the target mode to AUTO • Select the simulation mode "released" • Enter the desired input value, the quality and the status • Transfer the settings from the program to the transducer. You can observe the behavior of the output in SIMATIC PDM for example. You have to switch off the simulation afterwards to return to normal operation. 4.2.9 Status and Error Messages Linking ULTRAMAT / OXYMAT / CALOMAT with a PC software such as SIMATIC PDM allows error diagnosis. Current errors and maintenance requirements can be evaluated with SIMATIC PDM, in the View, Instrument State' menu. These messages are displayed in plain text which simplifies the appropriate action for eliminating the faults. 4.2.10 Resetting 4.2.10.1 Resetting to the As-delivered State If the ULTRAMAT / OXYMAT / CALOMAT is so badly adjusted that it is no longer able to perform its measuring task, you can restore the as-delivered state with this function. This function resets all parameters to their factory setting. Resetting is indicated by the diagnostic message told start executed". The status "Unsure, Initial value, Value constant" is output if no measured value result is available yet. 4.2.10.2 Resetting the PROFIBUS Address to 126 If no other instrument in your system has the preset address 126, you can add your ULTRAMAT/OXYMAT/CALOMAT to the PROFIBUS line during operation of the automation or control system. Then you have to change the address of the newly integrated instrument to a different value. If you remove an ULTRAMAT/OXYMAT/CALOMAT from the PROFIBUS line, you should reset its address to 126 with this function so that you can re-integrate it in this or another system when necessary. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 OXYMAT 61 112 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216683 5. Operation 5.1. Setting the Station Address ULTRAMAT 6/OXYMAT 6/CALOMAT 6/ OXYMAT 61 4r Note The basic principles of operation are explained in chapter 5 of the respective ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / OXYMAT 61 device manual. The station address can be set in the main menu under Configuration. The level 2 code is required for this. zs, 90 PROFIBUS-Config. CO2 Address 126 This function can be used to set the PROFIBUS station address. Addresses from 0...126 can be set. Warning Changing the station address can affect communication on the bus. ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 113 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216684 5.2. Setting the Station Address ULTRAMAT 23 Note The basic principles of operation are explained in chapter 5 of the ULTRAMAT 23 device manual. The station address can be set in the main menu under Configuration with the Special Functions submenu item. The level 2 code is required for this. Codes/Language AUTOCAL-drift ELAN / PROFIBUS Fact.Data/Res/Units ELAN Parameter ELAN ext.Interfer. PROFIBUS Parameters PROFIBUS Address : 126 Select the ELAN/PROFIBUS subitem from this menu Next select PROFIBUS Parameters subitem The PROFIBUS station address can be set in this dialog. Addresses between 0...126 can be set. Warning Changing the station address can affect communication on the bus. ULTRAMAT 6 I OXYMAT 6/ CALOMAT 6 ULTRAMAT 23 I OXYMAT 61 114 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216685 6. Maintenance The optional modules are maintenance-free. 6.1. Return The module must be sent to SIEMENS SPA CSC 1,chemin de la Sandlach F-67506 Haguenau for repairs. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 OXYMAT 61 115 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216686 6.2. Firmware If it becomes necessary to change the Firmware due to improvements, the flash EEPROM on the optional module (socket module) will have to be replaced. With CALOMAT 6 analyzers only firmware versions of 1.3.0 or later must be used. The firmware can be ordered as a spare part with the item number A5E00057164 from CSC Haguenau -> see chapter 6.1: SIEMENS SPA 6.2.1 ULTRAMAT 6, OXYMAT 6, CALOMAT 6, ULTRAMAT 23, OXYMAT 61 Firmware An update may sometimes be required when the PROFIBUS option is retrofitted: ULTRAMAT 6 (software version 4.2 or earlier) German English French Spanish Italian C79451-A3478-5501 C79451-A3478-5502 C79451-A3478-5503 C79451-A3478-5504 C79451-A3478-5505 OXYMAT 6 and OXYMAT 61 (software version 4.2 or earlier) German English French Spanish Italian CALOMAT 6 German English French Spanish Italian ULTRAMAT 23 C79451-A3480-5501 C79451-A3480-5502 C79451-A3480-5503 C79451-A3480-5504 C79451-A3480-5505 (software version 1.1.0 or earlier) A5E00092676 A5E00092677 A5E00092678 A5E00092679 A5E00092680 (software version 2.6 or earlier) All languages C79451-A3494-5501 ULTRAMAT 6 / OXYMAT 6/CALOMAT 6/ ULTRAMAT 23 I OXYMAT 61 116 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216687 7. Appendix 7.1. Operation with SIMATIC PDM Parameters can be set and measured values monitored using the SIMTIC PDM operating program and a PC or programming unit. You will find detailed information on the Internet at http://www.feldqeraete.de/00/produkte/simatic pdm/infos.html 7.2. Device Data Base File (GSD) PROFIBUS DP / PA requires files for cyclic data transmission which you can download from the Internet at German: English: http://www.ad.siemens.de/csi/qsd http://www.ad.siemens.de/csi e/gsd siem809c.gsd (3 KB) PA independant language siem809e.gsd (4 KB) DP independant language sie809cn.bmp (3 KB) Bitmap_Device 7.3. Technical Data PROFIBUS PA Bus voltage (according to DIN IEC 1158-2) 9 ... 32 V (not Exi) 9... 24 V option Exi Current consumption Baud rate 10 mA (typical) 31,25 kBitls Electrical isolation PROFIBUS against other electronics or housing: 1810 VAC PROFIBUS DP (according to EN 50170) Baud rates 9.6, 19.2, 93.75, 187.5, 500 kBit/s, 1.5, 3, 6,12 MBit/s Electrical isolation PROFIBUS against other electronics or housing: 50V= PROFIBUS DP / PROFIBUS PA C2-connections 4 connections to master class 2 are supported. automatic connection clearing 60 s after communications breakdown. ULTRAMAT 6 OXYMAT 61 CALOMAT 61 ULTRAMAT 23 OXYMAT 61 117 Schnittstelle PROFIBUS DP PA Interface A5E00054148.03 EFTA01216688 7.4. Diagnostic Information The following tables show the assignment of fault signals/maintenance requests from the devices to the diagnosis bits in the physical block. 7.4.1 ULTRAMAT 6 Diagnostic Information Fault (S) Maintenance request (W) No. Meaning of fault/maintenance request Diagnostic byte/bit Diagnosis bit name S1 Parameter memory 1 / 4 2 / 2 DIA_MEM_CHKSUM DIA CONF INVAL S2 Chopper motor fault 1 /1 DIA HW MECH S3 Microflow sensor 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S4 External fault 1 / 1 DIA HW MECH S5 Rec. chamber temp. 1 / 1 DIA HW MECH S6 Field device heating faulty 1 /0 DIA HW ELECTR S8 Pressure transducer signal 2 / 1 DIA SUPPLY S11 Reference gas pressure too low 2 / 1 DIA_SUPPLY S12 Power supply 2 / 1 DIA_SUPPLY S14 Measured value > characteristic curve upper value 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S15 Calibration cancelled 1 / 5 DIA MEASUREMENT S16 Measuring gas flow too low 2 / 1 DIA SUPPLY W1 Calibration difference too large 2 / 5 DIA MAINTENANCE W2 Zero point adjusting reserve < 20% 2 / 0 2 / 5 DIA_ZERO_ERR DIA MAINTENANCE W3 Signal voltage calibration too small 2 / 5 DIA MAINTENANCE W4 Set clock 2 / 5 DIA MAINTENANCE W5 Micraflow sensor 2 / 5 DIA MAINTENANCE W6 Temperature sensor LCD display 1 / 3 2 / 5 DIA_TEMP_ELECTR DIA_MAINTENANCE W7 Receiver chamber temperature > 70°C 2 / 5 DIA_MAINTENANCE W9 External maintenance request 2 / 5 DIA MAINTENANCE W10 Autocal check difference 2 / 5 DIA MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 118 EFTA01216689 7.4.2 CALOMAT 6 Diagnostic Information Fault (S) Maintenance request (W) No. Meaning of fault/maintenance request Diagnostic byte/bit Diagnosis bit name S1 Parameter memory 1 / 4 DIA_MEM_CHKSUM 2 / 2 DIA CONF INVAL S4 External fault 1 / 1 DIA HW MECH S5 TCD temperature 1 / 1 DIA HW MECH S12 Power supply 2 / 1 DIA SUPPLY S14 Measured value > characteristic curve 1 / 1 DIA_HW_MECH upper value 1 / 5 DIA_MEASUREMENT S15 Calibration cancelled 1 / 5 DIA MEASUREMENT W1 Calibration difference too large 2 / 5 DIA MAINTENANCE W4 Set clock 2 / 5 DIA MAINTENANCE W6 Temperature sensor LCD display 1 / 3 DIA_TEMP_ELECTR 2 / 5 DIA MAINTENANCE W9 External maintenance request 2 / 5 DIA MAINTENANCE W10 Autocal check difference 2 / 5 DIA MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 119 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216690 7.4.3 OXYMAT 6 and OXYMAT 61 Diagnostic Information Fault (F) Maintenance request (M) No. Meaning of fault/maintenance request Diagnostic byte/bit Diagnosis bit name S1 Parameter memory 1 / 4 DIA_MEM_CHKSUM 2 / 2 DIA CONF INVAL S2 Chopper motor fault 1 /1 DIA HW MECH S3 Microflow sensor 1 / 1 DIA_HW_MECH 1 / 5 DIA MEASUREMENT S4 External fault 1 / 1 DIA HW MECH S5 Receiver chamber temp. 1 / 1 DIA HW MECH S6 Field device heating faulty 1 / 0 DIA_HW_ELECTR S7 Measuring head temperature outside limits 1 / 1 DIA_HW_MECH S8 Pressure transducer signal 2 / 1 DIA SUPPLY S9 Signal too large 1 / 5 DIA MEASUREMENT S11 Reference gas pressure too low 2 / 1 DIA SUPPLY S12 Power supply 2 / 1 DIA SUPPLY S14 Measured value > characteristic curve 1 / 1 DIA_HW_MECH upper value 1 / 5 DIA MEASUREMENT S15 Calibration cancelled 1 / 5 DIA MEASUREMENT S16 Measuring gas flow too low 2 / 1 DIA SUPPLY W1 Adjustment tolerance exceeded 2 / 5 DIA MAINTENANCE W2 Signal voltage zero point too large 2 / 0 DIA_ZERO_ERR 2 / 5 DIA_MAINTENANCE W3 Signal voltage sensitivity too large 2 / 5 DIA_MAINTENANCE W4 Set clock 2 / 5 DIA_MAINTENANCE W5 Microffow sensor 2 / 5 DIA_MAINTENANCE W6 Temperature sensor LCD display 1 / 3 DIA_TEMP_ELECTR 2 / 5 DIA MAINTENANCE W7 Analyzing part temperature > 70 °C 2 / 5 DIA MAINTENANCE W8 Measuring head temperature outside 2 / 5 DIA_MAINTENANCE +- 3°C W9 External maintenance request 2 / 5 DIA MAINTENANCE W10 Autocal check difference 2 / 5 DIA MAINTENANCE ULTRAMAT 6/ OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 120 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 EFTA01216691 7.4.4 ULTRAMAT 23 Diagnostic Information Fault (F) Maintenance request (M) No. Meaning of fault/maintenance request Diagnostic byte/bit Diagnosis bit name S1 Channel 1 measured value outside limits 1 / 5 DIA MEASUREMENT S2 Channel 2 measured value outside limits 1 / 5 DIA MEASUREMENT S3 Channel 3 measured value outside limits 1 / 5 DIA MEASUREMENT S4 O2 measured value outside limits 1 / 5 DIA MEASUREMENT S5 Mains voltage outside limits 2 / 1 DIA SUPPLY S6 Device temperature outside limits 1 / 1 DIA HW MECH S7 Air pressure outside limits 2 / 1 DIA SUPPLY S8 No flow during measurement 2 / 1 DIA SUPPLY S9 No temperature adjustment carried out 1 /7 DIA INIT ERR S10 No flow with AUTOCAL 2 / 1 DIA SUPPLY S11 O2 measured value too small 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S12 Analog flow output faulty 1 /0 DIA HW ELECTR S13 Sumcheck error of all IR channels 1 / 1 1 / 5 DIA_HW_MECH DIA MEASUREMENT S14 Fault of address for IR channels 1 / 1 DIA HW MECH S15 AUTOCAL drift too large 2 / 0 DIA ZERO ERR S16 EEPROM error 1 /4 2 / 2 DIA_MEM_CHKSUM DIA CONF INVAL S17 Phase not found 1 / 1 DIA HW MECH S18 Serial interface fault 1 /0 DIA HW ELECTR S19 S20 Channel 1 not calibrated 1 /7 DIA INIT ERR S21 Channel 2 not calibrated 1 /7 DIA INIT ERR S22 Channel 3 not calibrated 1 /7 DIA INIT ERR S23 Transmitter voltage outside limits 1 /0 DIA HW ELECTR S24 Bridge supply voltage outside limits 1 /0 DIA HW ELECTR S25 Bridge half voltage outside limits 1 /0 DIA HW ELECTR S26 Lockin error 1 /0 DIA HW ELECTR S27 External fault 1 / 1 DIA HW MECH S28 S29 S30 S31 O2 sensor sensitivity too low 1 / 1 DIA HW MECH S32 External ADC error 1 /0 DIA HW ELECTR W1 AUTOCAL drift too large 2 / 5 DIA MAINTENANCE W2 O2 sensor 2 / 5 DIA MAINTENANCE W3 LCD temperature outside limits 1 / 3 2 / 5 DIA_TEMP_ELECTR DIA MAINTENANCE W4 External maintenance request 2 / 5 DIA MAINTENANCE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 121 EFTA01216692 7.5. Complete Object List 7.5.1 Device Managment Device Managment Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameter description Data Type Num bat Store (am. to ofile cy di c re ad we to MAND I 0 I 2 3 HEADER unsigned16 6 C x 0x0000 Dir ID Directory ID (reserved) Ox0001 Num Dir Rev Directory Revision Number Ox0001 Num Dir Obj Number of Directory Objects (Directories) 4 Ox0000 Num Dir Entries Total Number of Directory Entries 5 6 04001 First Comp Dir Entry Entry number of first Composite List Dir Entry 0x0003 Num Comp Dir Entry Number of Composite List Directory Entries MAND 1 1 COMPOSITE_LIST_DIRECTCRY_ ENTRY unsigned16 8 C x 1 0x0104 Start PB Ref Directory Index for Physical Block 2 1 Num PB Number of Physical Blocks 3 0x0205 Start TB Ref Directory Index for first Transducer Block 4 4 Num TB Number of Transducer Blocks 5 0x0309 Start FB Ref Directory Index for first Function Block Number of Function Blocks 6 5 Num FB _ 7 0x016E Slot Index PB Ph ical Block. slot 1. index absolute 110 8 ma Num PB Param Number of parameters MAND 1 2 COMPOSITE_LIST_DIRECTORY_ ENTRY unalgned16 8 C x 1 0x0142 Slot Index TI31 Transducer Block 1: Sot 1. index absolute 66 2 mix Num TBI Pam Number of parameters 3 0x0242 Slot Index 182 Transducer Block 2: slot 2 index absolute 66 4 mix Num TB2 Pam Number of parameters 5 0x0342 Slot Index T83 Transducer Block 3: Sot 3. index absolute 66 6 ra Nun TB3 Pam Number of parameters 7 0x0442 Slot Index TB4 Transducer Block 4: slot 4. index absolute 66 8 ma Nun TB4 Pam Number of parameters MAND 1 3 COMPOSITE_LIST_DIRECTCRY_ ENTRY unsIgned16 10 C x 1 Ox0110 Slot Index FB1 Function Block 1: slot 1. index absolute 16 2 sxr Nun FBI Pam Number of parameters 3 0x0210 Slot Index FB2 Function Block 2: slot 2. index absolute 16 4 sxr Nun FB2 Pam Number of parameters S 0x0310 Slot Index FB3 Function Block 3: slot 3. index absolute 16 6 7 mix Nun FB3 Pam Number of parameters 0x0410 Slot Index FB4 Function Block 4: slot 4. index absolute 16 8 ',cc Nun FBI Pam Number of parameters 9 Ox0510 Slot Index FB5 Function Block 5: slot 5. index absolute 16 10 pm Nun FBS Pam Number of parameters EFTA01216693 7.5.2 Function Block Al 1 Function Block Al 1 (Analog Input) Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameter descnpucc Data Type Nurn Der Store (acc. to profile) cy di c re ad wt le BLOCK 1 16 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-bp (Function) 3 1 Parent Class Parent class: 01 = Input I 4 5 1 0 Class 01 = Analog Input DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4002 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Exeation Time fOr future use I 10 45 Number0fParameters number of • arameters I 11 0x0141 Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists I STD 17 1 0 ST REV Identification / devkai / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x ' STD 18 2 Compone nt 1 TAG_DESC Unique tag in the system which can be used by the user visible_string 32 S x x STD 19 3 0 STRATEGY Strategy unsigned18 1 s x x STD 20 4 0 ALERT KEY User can write value for sled handing unsloned8 1 s x x STD 21 5 Ox08 TARGET MODE S' et mode of block = Auto unskined8 1 s x x x STD 22 6 MODE BLK Set block mode ds37 1 D 1 Ox08 Actual Actual mode 2 Ox98 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal 1 D x STD 2 0x0000 Unacknowl d Not acknowle 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled STD 24 8 BATCH Stored information for batch processes ds87 1 s x x 1 BATCH ID Batch identification 2 RUP Equipment 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Output value: measured value in select output mode, unit S sat in output scale ds33 1 D x x x 1 0 Value Output value 2 0x4F Stets Quality MAND 27 11 PV SCALE Input/ measured value scale float 2 s x x 1 100.0 E0100 Input / measured value scale / fullscale value / corresponding unit is set in output scale 2 0.0 EUO Input / measured value scale / initiate value / coires kig unit is set in output scale MAND 28 12 OUT SCALE Output/ output scale ds38 1 s x x 1 100.0 EU100 Output / output scale / fullscale value 2 0.0 EU0 Output / output scale / initiate value 3 UNIT Output / output scale / physical unit 4 Dec Point Decimal digits of output value MAND 29 13 0 LIN TYPE Linearization type unsigned8 1 s x x MAND 30 14 0x0109 CHANNEL Channel number number of transducer block and relative index unsigned16 1 s x x MAND 32 18 0.0 PV FTIME Output / fitter time constant in seconds float 1 s x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRkMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 123 EFTA01216694 Function Block Al 1 (Analog Input) cont. Class SI of Index abs Ind ex rel Elem ant Default Value Object Parameter descnption Data Type Num ber Store (acc. to profile) cy di c re ad wri to MAND 33 17 0 FSAVE_TYPE Output / failure behavar: type of reaction in case of sensor failure unsigned8 1 S x x MAND 34 18 0.0 FSAVE_VALUE Output/ safety default value in cased power failure float 1 S x x MAND 35 19 5.0 ALARM_HYS Output / safety default value in case of power failure float 1 S x x MAND 37 21 100.0 HI HI LIM Output / Output limit values! High alarm limit float 1 S x x MAND 39 23 100.0 HI LIM Output / Output limit values! High warning limit float 1 S x x MAND 41 25 0.0 LO LIM Output / Outpst limit values I Low warning limit float 1 S x x MAND 43 27 0.0 LO LO LIM Output / Output limit values! Low alarm limit float 1 S x x MAND 48 30 1 HI HI ALM Lligh alarm limit value status ds30 1 D x Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 Time stamp Time stamp 4 Subcode Suboode S Value Value MAND 47 31 HI ALM High warning lenit value status ds39 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 lime stamp Time stamp 4 Subcode Suboode S Value Value MAND 48 32 LO ALM Low waming limit value status ds39 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status I 3 Time stamp Time stamp I 4 Subcode Suboode S Value Value MAND 49 33 LO LO ALM Low alarm limit value status ds39 1 D x I 1 Unacknowl , • ! , d Not acknovAe • ! , d 3 Time stam• Time stam• 4 Subcode Suboode S Value Value MAND SO 34 SIMULATE Output / Simulation: simulation of the measured value (PRIMARY VALUE in Transducer Block ds50 1 S x x 1 Ox4b Simulate-Status Output! Simulation: simulation status 2 0.0 Simulate value Output/ Simulation: simulation value 3 0 Simulate_ENDisable Oulput I Simulation: simitabon enable — disable. Default disable (0) OPT 51 35 OUT_UNIT_TEXT Unit text, valid. If OUT SCALE.UNIT set to 'textual unit definition' (1095) viskie_string 16 S x x 52 36 bis reserved by PNO 80 44 VIEW 85 40 VIEW 1 ViewObjekt 1 AI void 4 o x 1 ST REV 6 MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 124 EFTA01216695 7.5.3 Transducer Block TB 1 Transducer Block TB 1 (Analyser) Class Slo I Index abs nd ex rel peen ent Default Value 'Detect I Parameter descnpacc Data Type Num be Store (acc. to profile) cy di c ea d writ a BLOCK 1 66 0 BLOCK OBJECT Block characteristic da32 1 C x 1 250 Reserved 250 = not used 2 3 Block Oblect Block-hp (Function) 3 4 7 1 Parent Class Parent class: 01 = Input ,lass 01= Analog Input 5 0 DID-Reference reserved 6 0 DID-Revision reserved 7 0x4002 Profie PA-profil-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 'rose Revision Profile 3.0 I 9 0 Execution Time fOr future use I 10 38 Uumber0fParameters number of parameters 11 Ox016d Address of VIEW t Index of view 1 12 1 Number of View Lists Number of Wews STD 87 1 0 ST REV Identification/ device / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 visible string 1 N x x x STD 68 2 TAG_DESC Unique tag in the system which can be used by the user 32 S STD 89 3 0 /STRATEGY Strategy User can mite value for alert handling unsigned16 _ unsigned8 1 1 S S x x x x STD 70 4 0 ALERT KEY STD 71 5 0x08 TARGET MODE Target mode of block = Auto unsigned8 1 S x x STD 72 6 NODE BLK Set block mode Elsa? 1 0 I x 1 0x08 kdual Actual mode 2 0x08 Permitted Permkted modes: Auto, 0/S. MAN 3 0x08 Normal Set mode in normal operation STD 73 7 ALARM SUM Alarm status de42 1 D x 1 Dx0000 Current Alarm Current Alarm 2 Dx0000 Unacknowledged Not acknowledged 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled MAND 74 8 Componen 1 COMPONENT_NAME Name of the measurand / component visible string 32 5 x x MAND 75 9 PV Measured value for AI-Block 1 Is60 1 D x 0.0 Value I OxOB Status Time MAND 76 10 1997 PV UNIT Unit of Primary Value (1997 = none) unsigned16 1 S x x MAND 77 11 PV UNIT_TEXT Unit Text of Primary Value risible string 8 s x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON Soolean 1 S x x MAND 80 14 400 /SAMPLING RATE sampling rate in miliseconds unsigned32 1 S x x 81 15 bls reserved bWNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsIgned8 1 C x MAND 92 28 RANGE 1 is81 1 N x x 0.0 Begin 100.0 End VIEW 109 43 /NEW 1 View-Objekt 1 odd s 0 x I ST REV 3 MODE BLK 7 PV ) ALARM SUM 12 ACTIVE_RANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 125 EFTA01216696 7.5.4 Physical Block Physical Block PB Class SI of Index abs Ind ex rel Elem an Default Value Object Parameter description Data Type Num ber Store (ace. to cy di 0 re ad wet to BLOCK 1 110 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used unsigned8 1 2 1 Block Object Block-bp (Function) unsigned8 1 3 5 Parent Class Parent class: 01 = Input _unsigned8 1 4 250 Class 01= Analog Input unsigned8 1 5 0 DO-Reference reserved uneipned32 1 6 0 DO-Revision reserved unsigned16 1 7 0x4002 Profile PA-prolil-number assigned by PNO for PROFIBUS - PA = 64 unsigned16 1 8 Ox0300 Profile Revision Profile 3.0 unsigned16 1 9 0 Execution Time for future use unsi,ned8 1 10 54 Number0fParameters ntrnber of parameters unsigned18 1 11 OxOlb7 Address of VIEW 1 Index of view t unsIgned16 1 12 1 Number of View Lists Number of views uneigned8 1 STD 111 1 0 ST_REV Identification / device! statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsIgned16 1 N x STD 112 2 Analyser TAG_DESC Unique tag in the system which can be used by the user visble_string 32 S x x STD 113 3 0 STRATEGY Strategy unsigned16 1 S x x STD 114 4 0 ALERT KEY User can write value for alert handling unsigned8 1 S x x STD 115 5 Ox08 TARGET MODE T: , -t mode of block = Auto unsi , nada 1 S x x STD 116 6 MODE BLK Set block mode Actual mode ds37 1 o x 1 Ox08 Actual 2 Ox88 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal operation STD 117 7 ALARM SUM Alarm status ds42 1 D x 1 2 0x0000 0x0000 Current Alarm Current Alarm Unacknowledged Not acknowledged 3 0x0000 Unreported Not reported 4 0x0000 Disabled Disabled MAND 118 8 / 0.23 SOFTWARE_REVISION Software Revision visble_string 16 D x MAND 119 9 HARDWARE REVISION Hardware Revision vials string 16 D x MAND 120 10 42 DEVICE MAN ID Manufacturer unsignedl6 1 C x MAND 121 11 DEVICE ID Device identification (unique) visible string visible string 16 16 C x MAND 122 12 DEV SER NUM Device serial number D x MAND 123 13 0x000000 00 DIAGNOSIS Detailed device informations (bit coded) octet_string octet string 4 6 0 0 x OPT 124 14 DIAGNOSIS EXTENSION Extended device information MAND 125 15 OxBBBFO 000 DIAGNOSIS MASK Bits supported by DIAGNOSIS octet_string 4 C x OPT 126 16 DIAGNOSIS MASK EXTENSION Bits supported by DIAGNOSIS EXTENSION octet string 6 C OPT 127 17 CE. NE21. Ex- cerlificatio n see plate DEVICE_CERTFICATION Device certification like EX. CE ykoble_sting 32 C x OPT 128 18 2457 WRITE LOCKING Password unsigned18 1 N x x OPT 129 19 0 FACTORY RESET Reset to Default-Values unsigned16 1 S x x OPT 130 20 dawn. • DESCRIPTOR visible stri , 32 S x x OPT 131 21 message DEVICE MESSAGE Message visible string octet_string 32 S x x x x OPT 132 22 01.01.200 0 DEVICE_INSTAL_DATE Date of device installation 16 S OPT 133 23 0 LOCAL OP ENA Local operation enable uneigned8 1 N x x x x MAND 134 24 1 IDENT_NUMBER_SELECTOR Profile analyser spec. (0) Profile spec. (3) Manufacturer spec. f11 DP-Ident Number uneigned8 1 S OPT 13S 25 HW WRITE PROTECTION Hardware- Write Protection uneigned8 1 D x 136 26 bis reserved by PNO 142 32 ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 126 EFTA01216697 Physical Block PB cont. Class SI of Index abs Ind ex rel Stem ent Default Value Object Parameter description Data Type Num ben Store (ace. to ofile cy di c re ad wn to additional parameters for analysers MAND 146 36 PROFIBU S option 2 DEVICE_CONFIGURATION visble_string 32 N x MAND 147 37 INIT STATE Status after Reset unsigned8 1 S x x MAND 148 38 2 DEVICE STATE Status of the device unsigned8 1 D x x MAND 149 39 0 GLOBAL STATUS unsigned18 1 D x 150 40 bis resented dutch PNO 157 47 SPEC 158 48 DIAGNOSIS SIMULATION Diagnosis-simulation record 2 D x x 1 0x000000 00 Value simulated value octet_string 4 2 0 Enable Enable 0: off 1: on unsigned8 1 SPEC 159 49 1 DIAGNOSIS ALARM ENABLE Enable cythc diagnosis programs unsigned8 1 s x x SPEC 160 50 CALIBRAT/ON DATA Calibration data record 2 S x x Data Calibration data octet_string visible string 8 24 Who Calibration site SPEC 161 51 PRODUCT CODE Order number (MLFB-No.) visible string 32 D x SPEC 162 52 0x000000 00 ERRORS Faults/ errors octet_string 4 D x SPEC 163 53 0x0000 WARNINGS Maintenance uests octet strip 2 D x VIEW 183 73 VIEW 1 View-Objekt I PB void 6 D x 1 ST REV 2 6 MODE BLK 3 7 ALARM SUM 4 13 DIAGNOSIS 5 38 DEVICE STATE 6 39 GLOBAL STATUS ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 127 EFTA01216698 7.5.5 Function Block Al 2 Function Block Al 2 (Analog Input) re ad I wit to Class SI of index abs Ind ex rel Elem ent Default Value Object Parameter descnpticc Data Type Num bet Store (acc. to profile) cy cl, c BLOCK 2 16 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-T)p (Function) 3 1 Parent Class Parent class: 01 = Input i 4 5 1 0 Class 01 = Analog Input DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4001 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time Mr future use I 10 45 Number0fParameters number of • arameters 11 0x0141 Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists STD 17 1 0 ST REV Identification / devkat / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x STD 18 2 Compone nt 2 TAG_DESC Unique tag in the system which can be used by the user vistle_sPing 32 S x x STD 19 3 0 STRATEGY Strategy unsIgned18 1 S x x STD 20 4 0 ALERT KEY User can write value for sled handing unlit:mega 1 S x x STD 21 5 Ox08 TARGET MODE S' et mode of block = Auto unskined8 1 S x x STD 22 6 MODE BLK Set block mode de37 1 D x 1 Ox08 Actual Actual mode 2 Ox98 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal 1 D x STD 2 Ox0000 Unacknowl d Not acknowle 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled STD 24 8 BATCH Stored information for batch processes deal 1 S x x BATCH ID Batch identification 2 RUP Equipment 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Output value: measured value in select output mode, unit S sat in output scale d533 1 D x x x 1 0 Value Output value 2 0x4F Stets Quality MAND 27 11 PV SCALE Input/ measured value scale float 2 S x x 1 100.0 EU100 Input/ measured value scale / fullscale value! corresponding unit is set in output scale 2 0.0 EUO Input/ measured value scale / initiate value! coires ig unit is set in output scale MAND 28 12 OUT SCALE Ouqxd/ output scale ds38 1 S x x 1 100.0 EU100 Output / output scale / tuneable value 2 0.0 EU0 Output/ output scale / initiate value 3 UNIT Output / output scale / physical unit 4 Dec Point Decimal digits of output value MAND 29 13 0 LIN TYPE Linearization type unsigned8 1 s x x MAND 30 14 0x0209 CHANNEL Channel number number of transducer block and relative index unsigned16 1 S x x MAND 32 18 04) PV_FTIME Output / filter time constant in seconds float 1 S x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 128 EFTA01216699 Function Block Al 2 (Analog Input) cont. 4i ay' to Class SI of Index abs Ind ex rel Elem ant Default Value Object Parameter descnption Data Type Num ber Store (ace. to profile) cy ck c re ad MAN 33 17 0 FSAVE_TYPE Output / failure behavar: type of reaction in case of sensor failure unsigned8 1 S x x MAN 34 18 0 FSAVE_VALUE Output/ safety default value in cased power failure float 1 S x x MAN 35 19 5.0 ALARM_HYS Output / safety default value in case of power failure float 1 S x x MAN 37 21 100.0 HI HI LIM Output? Output limit valutaaglih alarm frnit float 1 S x x MAN 39 23 100.0 HI UM Output /Output lima values I High warning limit float 1 S x x MAN 41 25 0.0 LO LIM Output / Output land values / Low warring limit float 1 S x x MAN 43 27 0.0 LO LO LIM Output / Output limit values / Low alarm limit float 1 S x x MAN 46 30 HI HI ALM High alarm limit value status da39 1 D 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 lime stamp Time stamp 4 Subcode Subcode s Value Value MAND 47 31 HI ALM tlIgh warning linit value status ds39 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 lime stem. Time stem. 4 Subcode Subcode s Value Value MAND 48 32 LO ALM Low warning limit value status ds39 1 D x 1 Unacknowl d Not acknowle d 2 Alarm State Alarm status 3 lime stem. Time stem. 4 Subcode Subcode s Value Value MAND 49 33 LO LO ALM Low alarm limit value status ds39 1 D x 1 Unacknowl d Not admoyAe d 2 Alarm State Alarm status 3 lime stamp Time stamp 4 Subcode Subcode s Value Value MAND SO 34 SIMULATE Output / Simulation: simulation of the measured value (PRIMARY VALUE in Transducer Block ds50 1 S x x 1 Ox4b Simulate-Status Output? Simulation: simulation status 2 0.0 Simulate value Output / Simulation: simulation value 3 0 Simulate_ENDisable Output/ Simulation: simitakon enable — disable. Default disable (0) OPT 51 35 OUT_UNIT_TEXT Unit text, wild. if OUT_SCALE.UNIT set to 'textual unit definition' (1005) visige_string 16 5 x x 52 36 bis resenAert von PNO 60 44 VIEW 66 40 VIEW 1 View-Objekt 1 Al told 4 0 x 1 ST REV 6 MODE BLK 7 ALARM_SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 129 EFTA01216700 7.5.6 Transducer Block 2 Transducer Block TB2 (Analyser) Class SI of Index abs Ind ex rel Bern ent Default Value Object Parameter description Data Type Num Per Store (am. to profile) cy di c re ad wit to BLOCK 2 66 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Block-bp (Function) 3 7 Parent Class Parent class: 01 = Input i 4 1 Class 01 = Analog Input 5 0 DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4002 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.() 9 0 Execution Time (Or future use I 10 27 NumberOfParameters number of arameters 11 0x0264 Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists STD 67 1 0 ST REV Identification / device! statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x STD 68 2 TAG_DESC Unique tag in the system which can be used by the user visble_string 32 S x x STD 69 3 0 STRATEGY Strategy unsigned16 1 S x x STD 70 4 0 ALERT KEY User can write value for sled handing unsloned8 1 S x x STD 71 5 0x08 TARGET MODE S' et mode of block = Auto unsigned8 1 S x x STD 72 6 MODE BLK Set block male ds37 1 D x 1 0x08 Actual Actual mode 2 0x08 Permitted Permitted modes: Auto. O/S. MAN 3 0x08 Normal Set mode in normal o STD 73 7 ALARM SUM Alarm status dM2 1 D x 1 0x0000 Current Alarm Current Alarm 2 0x0000 Unacknowl d Not acknowle d 3 0x0000 Unreported Not re oiled 4 0x0000 Disabled Disabled visble_string MAND 74 8 Compone nt 2 COkWONENT_NAME Name of the measurand / component 32 S x x MAND 75 9 PV Measured value for Al-Block I ds60 1 D x 0.0 Value 0x0B Status Time MAND 76 10 1097 PV UNIT Link of Primary Value (1997 = none) unsigned16 viable string 1 8 S x x MAND 77 11 PV UNIT TEXT Unit Text of Primary Value 5 x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON boolean 1 S x x MAND ea 14 400 SAWUNG RATE sampling rate in miliseconds unsigned32 1 S x x 81 15 bb reserved by PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 26 RANGE 1 dal 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 D x 1 ST REV 6 MODE BLK ) PV 7 ALARM SUM 12 ACTIVE RANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 130 EFTA01216701 7.5.7 Function Block Al 3 Function Block Al 3 (Analog Input) re ad I wit to Class SI of index abs Ind ex rel Elem ent Default Value Object Parameter descnoticc Data Type Num bet Store (acc. to profile) cy cl, c BLOCK 3 16 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-bp (Function) 3 1 Parent Class Parent class: 01 = Input i 4 5 1 0 Class 01 = Analog Input DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4001 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time fOr future use I 10 45 Number0fParameters number of • arameters 11 0x0341 Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists STD 17 1 0 ST REV Identification / devkai / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x STD 18 2 Compone nt 3 TAG_DESC Unique tag in the system which can be used by the user visible_string 32 S x x STD 19 3 0 STRATEGY Strategy unsIgned18 1 S x x STD 20 4 0 ALERT KEY User can write value for sled handing unslaned8 1 S x x STD 21 5 Ox08 TARGET MODE S' et mode of block = Auto unskined8 1 S x x STD 22 6 MODE BLK Set block mode de37 1 D x 1 Ox08 Actual Actual mode 2 Ox98 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal 1 D x STD 2 0x0000 Unacknowl d Not acknowle 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled STD 24 8 BATCH Stored information for batch processes ds87 1 S x x BATCH ID Batch identification 2 RUP Equipment 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Output value: measured value it select output mode, unit S sat in output scale ds33 1 D xx x 1 0 Value Output value 2 0x4F Stets Quality MAND 27 11 PV SCALE Input/ measured value scale float 2 S x x 1 100.0 EU100 Input/ measured value scale / fullscale value! corresponding unit is set in output scale 2 0.0 EUO Input/ measured value scale / initiate value! coires kig unit is set in output scale MAND 28 12 OUT SCALE Ouqxd/ output scale ds38 1 S x x 1 100.0 EU100 Output / output scale / tuneable value 2 0.0 EU0 Output/ output scale / initiate value 3 UNIT Output / output scale / physical unit 4 Dec Point Decimal digits of output value MAND 29 13 0 LIN TYPE Linearization type unsigned8 1 S x x MAND 30 14 0x0309 CHANNEL Channel number number of transducer block and relative index unsigned16 1 S x x MAND 32 18 0.0 PV_FTIME Output / filter time constant in seconds float 1 S x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E000541413-03 131 EFTA01216702 Function Block Al 3 (Analog Input) cont. 4i ay' to Class SI of Index abs Ind ex rel Elem ant Default Value Object Parameter descnption Data Type Num ber Store (ace. to profile) cy ck c re ad MAN 33 17 0 FSAVE_TYPE Output / failure behavar: type of reaction in case of sensor failure unsigned8 1 S x x MAN 34 18 0 FSAVE_VALUE Output/ safety default value in cased power failure float 1 S x x MAN 35 19 5.0 ALARM_HYS Output / safety default value in case of power failure float 1 S x x MAN 37 21 100.0 HI HI LIM Output? Output limit valutaaglih alarm frnit float 1 S x x MAN 39 23 100.0 HI UM Output /Output lima values I High warning limit float 1 S x x MAN 41 25 0.0 LO LIM Output / Output land values / Low warring limit float 1 S x x MAN 43 27 0.0 LO LO LIM Output / Output limit values / Low alarm limit float 1 S x x MAN 46 30 HI HI ALM High alarm limit value status da39 1 D 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 lime stamp Time stamp 4 Subcode Subcode s Value Value MAND 47 31 HI ALM tlIgh warning linit value status ds39 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 lime stem. Time stem. 4 Subcode Subcode s Value Value MAND 48 32 LO ALM Low warning limit value status ds39 1 D x 1 Unacknowl d Not acknowle d 2 Alarm State Alarm status 3 lime stem. Time stem. 4 Subcode Subcode s Value Value MAND 49 33 LO LO ALM Low alarm limit value status ds39 1 D x 1 Unacknowl d Not admoyAe d 2 Alarm State Alarm status 3 lime stamp Time stamp 4 Subcode Subcode s Value Value MAND SO 34 SIMULATE Output / Simulation: simulation of the measured value (PRIMARY VALUE in Transducer Block ds50 1 S x x 1 Ox4b Simulate-Status Output? Simulation: simulation status 2 0.0 Simulate value Output / Simulation: simulation value 3 0 Simulate_ENDisable Output/ Simulation: simulakon enable — disable. Default disable (0) OPT 51 35 OUT_UNIT_TEXT Unit text, wild. if OUT_SCALE.UNIT set to 'textual unit definition' (1005) visige_string 16 5 x x 52 36 bis resenAert von PNO 60 44 VIEW 65 40 VIEW 1 View-Objekt 1 AI told 4 0 x 1 ST REV 6 MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 132 EFTA01216703 7.5.8 Transducer Block TB 3 Transducer Block TB 3 (Analyser) Class SI of index abs Ind ex rel Elem ent Default Value Object I Parameter clescnpficc Data Type Nurn Der Store (am. to profile) cy di c re ad arts to BLOCK 3 66 0 BLOCK OBJECT Block cheractedstic ds32 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Ellock-bp (Function) 3 7 Parent Class Parent class: 01 = Input 4 1 Class 01 = Analog Input 5 0 DO-Reference reserved 8 0 DO-Revision reserved 7 0x4002 Profile PA-profil-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time (Or future use 10 27 Number0fParameters number of arameters I 11 0x036d Address of VIEW 1 Number of View Lists Index of view 1 Number of views I 12 1 I STD 67 1 0 ST REV Identification / device / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x ' STD 88 2 Compone nt 3 TAG_DESC Unique tag in the system which can be used by the user visible_string 32 S x x STD 69 3 0 STRATEGY Strategy unsigned16 1 S x x STD 70 4 0 ALERT KEY User can write value for sled handing unsioned8 1 S x x STD 71 5 Ox08 TARGET MODE S' et mode of block = Auto unslgned8 1 5 x x STD 72 6 MODE BLK Set block male ds37 1 D x 1 Ox08 Actual Actual mode 2 Ox08 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal o STD 73 7 ALARM SUM Alarm status 6342 1 D x 1 0x0000 current Alarm Current Alarm 2 0x0000 Unacknowl d Not acknowle d 3 0x0000 Unreported Not reported 4 0x0000 Disabled Disabled x MAND 74 8 COMPONENT NAME Name of the measurand I component visible string 32 5 x MAND 75 9 PV Measured value for AI-Block 1 ds60 1 D x 0.0 Value OxOB Status Time x x MAND 76 10 1997 PV UNIT Unit of Primary Value (1997 = none) unsigned16 1 5 MAND 77 11 PV UNIT TEXT Unit Text of Primary Value visible string 8 5 x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON boolean 1 S x x MAND 80 14 300 SAMPLING RATE )iampling rate in milliseconds unsioned32 1 S x x 81 15 bis reserved by PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 26 RANGE 1 ds81 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 D x 1 ST REV 6 MODE BLK 7 PV 8 ALARM SUM 12 ACTIVE RANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRkMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 133 EFTA01216704 7.5.9 Function Block Al 4 Function Block Al 4 (Analog Input) re ad 1 wit le Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameter clescepticc Data Type Num ber Store (acc. to proNe) cy cb c BLOCK 4 16 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Ellock-bp (Function) 3 1 Parent Class Parent class: 01 = Input i 4 5 1 0 Class 01 = Analog Input DO-Reference reserved _ 8 0 DO-Revision reserved I 7 0x4001 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time (Or future use I 10 45 Number0fParameters number of • arameters I 11 Ox0441 Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists STD 17 1 0 ST REV Identification / devkat / statistic rev.-no. / Function Block: counter which is incremented at an ch of con •'Nation meters unsigned16 1 N x STD 18 2 Compone nt 4 TAG_DESC Unique tag in the system which can be used by the user vimble_string 32 S x x STD 19 3 0 STRATEGY Strategy unsigned18 1 S x x STD 20 4 0 ALERT KEY User can write value for sled handing unsianed8 1 S x x STD 21 5 Ox08 TARGET MODE S' et mode of block = Auto unsigned8 1 S x x x STD 22 6 MODE BLK Set block mode ds37 1 D 1 Ox08 Actual Actual mode 2 Ox98 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal o 1 D x STD 2 Ox0000 Unacknowl d Not acknowle d 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled STD 24 8 BATCH Stored information for batch processes ds87 1 S x x 1 BATCH ID Batch identification 2 RUP Equipment 3 OPERATION Operation 4 PHASE Phase MAND 26 10 OUT Output value: measured value it select output mode, unit S sat in output scale ds33 1 D x x x 1 0 Value Output value 2 0x4F Stets Quality MAND 27 11 PV SCALE Input/ measured value scale float 2 S x x 1 100.0 EU100 Input/ measured value scale / fullscale value! corresponding unit is set in output scale 2 0.0 EUO Input/ measured value scale / initiate value! coires kig unit is set in output scale MAND 28 12 OUT SCALE Oulptrt/ output scale ds36 1 S x x 1 100.0 EU100 Output/ output scale / (disable value 2 0.0 EU0 Output/ output scale / initiate value 3 UNIT Output/ output scale / physical unit 4 Dec Point Decimal digits of output value MAND 29 13 0 LIN TYPE Linearization type unsigned8 1 S x x MAND 30 14 0x0409 CHANNEL Channel number number of transducer Nock and relative index unsigned16 1 S x x MAND 32 18 04) PV_FTIME Output! filter time constant in seconds float 1 S x x ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 134 EFTA01216705 Function Block Al 4 (Analog Input) cont. 4i ay' to Class SI of Index abs Ind ex rel Elem ant Default Value Object Parameter descnption Data Type Num ber Stare (ace. to profile) cy ck c re ad MAN 33 17 0 FSAVE_TYPE Output! failure behavar: type of reaction in case of sensor failure unsigned8 1 S x x MAN 34 18 0 FSAVE_VALUE Output/ safety default value in cased power failure float 1 S x x MAN 35 19 5.0 ALARM_HYS Output! safety default value in case of power failure float 1 S x x MAN 37 21 100 HI HI LIM Out irI utput limit values! Hiph stern knit float 1 S x x MAN 39 23 100 HI UM Output! Output limit values! High warning limit float 1 S x x MAN 41 25 0 LO LIM Output / Output limit values! Low warning limit float 1 S x x MAN 43 27 0 LO LO LIM Output! Output limit values / Low alarm limit float 1 S x x MAN 46 30 HI HI ALM High alarm limit value status ds39 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 Time stamp Time stamp 4 Subcode Subcode s Value Value MAND 47 31 HI ALM tljgh warning lien value status &GO 1 D x 1 Unacknowledged Not acknowledged 2 Alarm State Alarm status 3 Time stem. Time stem. 4 Subcode Subcode s Value Value MAND 48 32 LO ALM Low warning limit value status ds39 1 D x 1 Unacknowl d Not acknowle d 2 Alarm State Alarm stabs 3 lime stem. Time stem. 4 Subcode Subcode s Value Value MAND 49 33 LO LO ALM Low alarm limit value status ds39 1 D x 1 Unacknowl d Not adinowle d 2 Alarm State Alarm status 3 Time stamp Time stamp 4 Subcode Subcode s Value Value MAND SO 34 SIMULATE Output / Simulation: simulation of the measured value (PRIMARY VALUE in Transducer Block ds50 1 S x x 1 Ox4b Simulate-Status Output / Simulation: simulation status 2 0.0 Simulate value Output! Simulation: simulation value 3 0 Simulate_ENDisable Output/ Simulation: simulaton enable — &sable. Default disable (0) OPT 51 35 OUT_UNIT_TEXT Unit text, wild. If OUT_SCALE.UNIT set to 'textual unit definite& (1005) visa:40_0'm 16 S x x 52 36 bis resendert von PNO 60 44 VIEW 65 40 VIEW 1 ViewObjekt 1 AI veld 4 0 x 1 ST REV 6 MODE BLK 7 ALARM SUM 10 OUT ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 135 EFTA01216706 7.5.10 Transducer Block TB 4 Transducer Block TB 4 (Analyser) Class Si of index abs Ind ex rel Elem ent Default Value Object I Parameter descnpficc Data Type Nurn Der Store (am. to profile) cy di c re ad wit to BLOCK 4 66 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 3 Block Object Block-bp (Function) 3 7 Parent Class Parent class: 01 = Input I 4 1 Class 01 = Analog Input 5 0 DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4002 Profile PA-prolll-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time (Or future use I 10 27 Number0fParameters number of arameters 11 0x046d Address of VIEW 1 Number of View Lists Index of view 1 Number of views 12 1 STD 67 1 0 ST REV Identification / device / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x STD 88 2 Compone nt 4 TAG_DESC Unique tag in the system which can be used by the user visble_string 32 S x x STD 69 3 0 STRATEGY Strategy unsigned16 1 s x x STD 70 4 0 ALERT KEY User can write value for sled handing unsloned8 1 S x x STD 71 5 Ox08 TARGET MODE S' et mode of block = Auto unsigned8 1 S x x STD 72 6 MODE BLK Set block mode ds37 1 D x 1 Ox08 Actual Actual mode 2 Ox08 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal o STD 73 7 ALARM SUM Alarm status dM2 1 D x 1 0x0000 current Alarm Current Alarm 2 0x0000 Unacknowl d Not acknowle d 3 0x0000 Unreported Not re oiled 4 0x0000 Disabled Disabled visble_string MAND 74 8 Compone nt 4 COMPONENT_NAME Name of the measurand / component 32 S x x MAND 75 9 PV Measured value for AI-Block 1 ds60 1 D x 0.0 Value OxOB Stabs Time MAND 76 10 1097 PV UNIT Link of Primary Value (1997 = none) unsigned16 viable string 1 8 S x x MAND 77 11 PV UNIT TEXT Unit Text of Primary Value s x x MAND 78 12 1 ACTIVE RANGE unsigned8 1 S x x MAND 79 13 0 AUTORANGE ON bootean 1 S x x MAND 60 14 400 SAMPLING RATE samplingrate in miliseconds unsi ned32 1 S x x 81 15 bb reserviert dutch PNO 90 24 MAND 91 25 1 NUMBER OF RANGES unsigned8 1 C x MAND 92 28 RANGE 1 dal 1 N x x 0.0 Begin 100.0 End VIEW 109 43 VIEW 1 View-Objekt 1 void 5 D x 1 ST REV 6 MODE BLK 7 PV 8 ALARM SLIM 12 ACTIVE RANGE ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRkMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 136 EFTA01216707 7.5.11 Function Block DO Function Block DO (Digital Output) 2 Class SI of Index abs Ind ex rel Bern ent Default Value Object I Parameter Oescnpucc Data Type Nurn tier Store (am. to profile) cy di c re ad wit to BLOCK S 16 0 BLOCK OBJECT Block characteristic ds32 1 C x 1 250 Reserved 250 = not used 2 2 Block Object Block-Tip (Function) 3 2 Parent Class Parent class: 01 = Input i 4 S 2 0 Class 01 = Analog Input DO-Reference reserved 8 0 DO-Revision reserved I 7 0x4002 Profile PA-profit-number assigned by PNO for PROFIBUS - PA = 64 8 0x0300 Profile Revision Profile 3.0 9 0 Execution Time (Or future use I 10 45 Number0fParameters number of arameters I 11 0x0S4b Address of VIEW 1 Index of view 1 Number of views 12 1 Number of View Lists STD 17 1 0 ST REV Identification / devka / statistic rev.-no. / Function Block: counter which is incremented at any change of configuration parameters unsigned16 1 N x STD 18 2 TAG_DESC Unique tag in the system which can be used by the user visible_string 32 S x x STD 19 3 0 STRATEGY Strategy unsigned18 1 S x x STD 20 4 0 ALERT KEY User can write value for sled handing unsloned8 1 S x x STD 21 5 Ox08 TARGET MODE S' et mode of block = Auto uns1gned8 1 S x x STD 22 6 MODE BLK Set block male ds37 1 D x 1 Ox08 Actual Actual mode 2 0x98 Permitted Permitted modes: Auto. 0/S. MAN 3 Ox08 Normal Set mode in normal o STD 23 7 1 ALARM SUM Alarm status 6342 1 D x 0x0000 Current Alarm Current Alarm 2 0x0000 Unacknowledged Not acknowle d 3 Ox0000 Unreported Not reported 4 Ox0000 Disabled Disabled STD 24 8 BATCH Information for Batch-Process de67 1 S x x 1 BATCH ID 2 RUP 3 OPERATION 4 PHASE 9 1 x x MAND 25 0 Value ds34 D Ox1B Status 0(A). M(B) 26 10 ds34 1 D x x 0 Value 12 Ox4F Stabs 1 x OPT 28 ds34 D 0 Value Ox4F Shad 0(A). MB 30 14 ds34 1 D x x 0 Value Ox1B Status SPEC Ox0123 IN CHANNEL Pointer for input (FEEDBACK) unsigned16 1 N x 0(A). MB 33 17 0x0122 CHANNEL Pointer for output (POSITIONING VALUE) unsigned% 1 S x MAND 34 18 0 INVERT unsipned8 1 S x x 0(A). M(B) 35 19 30.0 FSAVE_TIME float 1 S x x 0(A). M(B) 36 20 1 FSAVE_TYPE unsignedS 1 S x x 0(A). M(B) 37 21 0 unsignedS 1 S x x 0(A). M(B) 38 22 I ds34 1 D x 0 Value ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00064148-03 137 EFTA01216708 Function Block DO (Digital Output) cont. Class SI of Index abs Ind ex rel Elem ent Default Value Object Parameterbeschretbung Data Type Num bar Store (acc. to profile) cy ci c re ad wri to 0x4F Status O(A), M(B) 40 24 SIMULATE dal 1 S x x o Status 0 Value 0 Enabled MAND 49 33 0x000000 CHECKBACK octet string 3 D x MAND SO 34 0x000000 CHECKBACK MASK octet string 3 C x 51 35 bIs resell/ kin van der PNO ea 44 VIEW 75 59 VIEW 1 View-Oblekt 1 void 3 D x 1 ST REV 6 MODE BLK 7 ALARM SUM ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 138 EFTA01216709 Notizen / notes ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTFtAMAT 23 / OXYMAT 61 Schnittstelle PROFIBUS DP / PA Interface A5E00054148-03 139 EFTA01216710 Simms AG Asplomalite & !him Divetion MI II 0.76181 Earbrubc Vein. A::100 Sittutil Induce nfMul mot mile.. Siemens Aktienmellschaft IleskIlAr.4 •••• el/0141M PANS la( annul, A(.01021.1 PI in lkis Excellence Automation & Drives: Siemens EFTA01216711

Technical Artifacts (27)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

IPv6A::
Phone4071041
Phone4159321
Phone478-5501
Phone478-5502
Phone478-5503
Phone478-5504
Phone478-5505
Phone480-5501
Phone480-5502
Phone480-5503
Phone480-5504
Phone480-5505
Phone494-5501
Phone740700.0101
Phone8445400
URLhttp://home.t-online.de/home/hartmut.flaemig/pa_intro.htm
URLhttp://www.ad.siemens.de/csi
URLhttp://www.ad.siemens.de/csi/qsd
URLhttp://www.ad.siemens.de/csikisd
URLhttp://www.ad.siemens.de/profibus/html
URLhttp://www.feldgeraete.de/00/produkte/simatic
URLhttp://www.feldqeraete.de/00/produkte/simatic
Wire RefRef Directory
Wire RefReference
Wire Refreference
Wire Refrefreshment

Related Documents (6)

DOJ Data Set 10OtherUnknown

EFTA01294870

10p
Dept. of JusticeOtherUnknown

EFTA Document EFTA01277005

*UBS IRS Financial Services tic. Private Wealth Management 299 Park Avenue 26th Floor New York NY 10171.0002 ANP70036969670219 • 0 Account name: MAX FOUNDATION Friendly account name: MAX FOUNDATION Account number. Your linens:WI Advisor- SCOTT STACKMANitYLE CASK EL Questions about your statement? call y0ur fir-Jan:re' AdvJiOr Of ti e Resourcetine at account VIsItour webs's.: www.ubitOnYlinanCiakerviCeS Items for your attention Help protect ycJitelf lion, liaw and review bank,

56p
DOJ Data Set 9OtherUnknown

Memorandum

Memorandum Subject Re: Operation Leap Year Date May 1, 2007 (Revised 9/13/07) (2nd Revision 2/19/08)' To From R. Alexander Acosta, United States Attorney First Assistant United States Attorney Chief, Criminal Division MAUSA, Northern Region , Chief, Northern Region I. Introduction This memorandum seeks approval for the attached indictment char in Jeffrey Epstein, Min a/k/a' JEGE Inc., and Hyperion Air, Inc. The proposed indictment contains 60 counts and seeks the forfeiture of Epstein's Palm Beach home and two airplanes? The FBI has information regarding Epstein's whereabouts on May 16th and May 19th and they would like to arrest him on one of those dates. Epstein is considered an extremely high flight risk' and, from information we have received, a continued danger 'The second revision amends the Jane Doe numbering system to correspond with the most recent indictment. It also removes the references to the overt acts and substantive allegations related to each

53p
DOJ Data Set 9OtherUnknown

DS9 Document EFTA00298259

34p
Court UnsealedTestimonyUnknown

court transcript: A-5918

The document is a court transcript where MS. DAVIS argues that Mr. Parse's attorney made strategic choices that benefited him, and that MR. SHECHTMAN has not met the Strickland standard for ineffective assistance of counsel. The court had previously ruled on a motion for a new trial related to Catherine Conrad, a juror who was known to the defendant's law firm, Brune & Richard.

1p
Dept. of JusticeOtherUnknown

EFTA Document EFTA01299130

KYC Print Page 1 of' 19 DB PWM GLOBAL KYC/NCA: PART A Int KYC Case # : 01141308 One sheet must be established per relationship - list all accounts included in the relationship 1. Relationship Details Relationship Name: EPSTEIN, JEFFREY RELATIONSHIP:00000483290 Booking Center: New York Relationship Manager: Paul Moms Relationship to PWM: 17 New PWM Relationship F Existing PWM Relationship If existing, please indicate since when the relationship exists, provide reason for new profi

19p

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.