Case File
efta-01847610DOJ Data Set 10OtherEFTA01847610
Date
Unknown
Source
DOJ Data Set 10
Reference
efta-01847610
Pages
2
Persons
0
Integrity
Extracted Text (OCR)
Text extracted via OCR from the original document. May contain errors from the scanning process.
From:
Jeffrey Epstein
Sent
Wed 3/7/2012 12:02:20 AM
Ergonomically and for safety reasons, stairs must have certain measurements so that people can
comfortably use them. Building codes typically specify certain measurements so that the stairs are
not too steep or narrow. American building codes specify the following parameters:owl
• Minimum tread length, typically 9 inches (229 mm) excluding the nosing for private
residences. Some building codes also specify a minimum riser height, often 5 inches
(127 mm).10
• Riser-Tread formula: Sometimes the stair parameters will be something like riser + tread
equals 17-18 inches (432-457 mm);19-lanother formula is 2 times riser + tread equals 24.6
inches (625 mm), the length of a stride.IAIThus a 7 inches (178 mm) rise and a 10.6 inches
(269 mm) tread exactly meets this code. If only a 2 inches (51 mm) rise is used then a 20.6
inches (523 mm) tread is required. This is based on the principle that a low rise is more like
walking up a gentle incline and so the natural swing of the leg will be longer. This makes
low rise stairs very expensive in terms of the space consumed. Such low rise stairs were
built into the Winchester Mystery House to accommodate the infirmities of the owner,
Sarah Winchester, before the invention of the elevator. These stairways, called "Easy
Risers" consist of five flights wrapped into a multi-turn arrangement with a total width
equal to more than four times the individual flight width and a depth roughly equal to one
flight's run plus this width. The flights have varying numbers of steps.
• Slope: A value for the rise-to-tread ratio of 17/29 = 0.59 is considered optimal; this
corresponds to a pitch angle of about 30°.
• Variance on riser height and tread depth between steps on the same flight should be very
low. Building codes require variances no larger than 0.1875 inches (4.76 mm) between
depth of adjacent treads or the height of adjacent risers; within a flight, the tolerance
between the largest and smallest riser or between the largest and smallest tread can not
exceed 0.375 inches (9.5 mm).1lin The reason is that on a continuous flight of stairs, people
get used to a regular step and may trip if there is a step that is different, especially at night.
The general rule is that all steps on the same flight must be identical. Hence, stairs are
typically custom made to fit the particular floor to floor height and horizontal space
available. Special care must be taken on the first and last risers. Stairs must be supported
directly by the subfloor. If thick flooring (e.g. thick hardwood planks) are added on top of
the subfloor, it will cover part of the first riser, reducing the effective height of the first
step. Likewise at the top step, if the top riser simply reaches the subfloor and thick flooring
is added, the last rise at the top may be higher than the last riser. The first and last riser
heights of the rough stairs are modified to adjust for the addition of the finished floor.
• Maximum nosing protrusion, typically 1.25 inches (32 mm) to prevent people from
tripping on the nosing.
• Height of the handrail. This is typically between 34 and 38 inches (864 and 965 mm),
measured to the nose of the tread. The minimum height of the handrail for landings may be
different and is typically 36 inches (914 mm).
• Handrail diameter. The size has to be comfortable for grasping and is typically between
1.25 and 2.675 inches (32 and 67.9 mm).
EFTA_R1_00238260
EFTA01847610
• Maximum space between the balusters of the handrail. This is typically 4 inches
(102 mm).
• Openings (if they exist) between the bottom rail and treads arc typically no bigger than 6
inches (152 mm).
• Headroom: At least 83 inches (211 cm).13-1
• Maximum vertical height between floors or landings. This allows people to rest and
limits the height of a fall.
• Mandate handrails if there is more than a certain number of steps (typically 2 risers)
• Minimum width of the stairway, with and without handrails
• Not allo
*****************
**********
******************
**************
The information contained in this communication is
confidential, may be attorney-client privileged, may
constitute inside information, and is intended only for
the use of the addressee. It is the property of
Jeffrey Epstein
Unauthorized use, disclosure or copying of this
communication or any pan thereof is strictly prohibited
and may be unlawful. If you have received this
communication in error, please notify us immediately by
return e-mail or by e-mail to [email protected], and
destroy this communication and all copies thereof,
including all attachments. copyright -all rights reserved
EFTA_R1_00238261
EFTA01847611
Technical Artifacts (1)
View in Artifacts BrowserEmail addresses, URLs, phone numbers, and other technical indicators extracted from this document.
Email
[email protected]Related Documents (6)
DOJ Data Set 10OtherUnknown
EFTA01682184
186p
OtherUnknown
FEDWIRE PAYMENT DEBIT ADVICE
DOJ EFTA Data Set 10 document EFTA01273102
16p
DOJ Data Set 10OtherUnknown
EFTA01370863
1p
Dept. of JusticeOtherUnknown
Medical Record/Clinical Encounter: DOJ-OGR-00026334
This clinical encounter document from the Bureau of Prisons details a medical evaluation of Jeffrey Epstein on July 12, 2019. It covers his medical history, current complaints, and treatment, including discussions around his triglyceride levels, sleep apnea, and back pain. The document was generated by the treating physician at the Metropolitan Correctional Center in New York.
1p
DOJ Data Set 8CorrespondenceUnknown
EFTA00014087
0p
DOJ Data Set 10OtherUnknown
EFTA01977826
2p
Forum Discussions
This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.
Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.