Case File
efta-efta00590796DOJ Data Set 9OtherGulfstreame
Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta00590796
Pages
123
Persons
0
Integrity
No Hash Available
Extracted Text (OCR)
Text extracted via OCR from the original document. May contain errors from the scanning process.
Gulfstreame
PRELIMINARY INVOICE
A 0•NARAL OVINIAMIC• COMPANY
7 Char Drive - Westfield. Massachusetts 01085-1493
Part Model #: GIV
AC Serial No/Tail No.:
Mail Remittance To:
Gulfstream Aerospace Corporation
P.O. Box 730349
Dallas. Texas 75373-0349
Overnight Remittance To:
Gu[(stream Aerospace Corporation (Box # 730349)
do JP Morgan Chase Bank. NA
ATTN: Dallas National Wholesale Lockbox TXI-0029
14800 Frye Road
R. Worth. TX 76155
Wire Remittance To:
Gulfstream Aerospace Corporation
JP Morgan Chase Bank. NA
Chicago. IL 60670
Account No. 10-15825
Fedwire Routing No. (ABA) 02I 000 021
S.W.I.F.T. CHASUS33
ACH Credit Routing No. (ABA)071 000 013
3 4 0 6 4 s
Bill To: JEGE LLC
C/O GALAXY AVIATION INC
ATTN: LARRY VISOSKI
3800 SOUTHERN BLVD, SUITE 204
WEST PALM BEACH, Florida 33406
United States
Invoice Number:
Invoice Date:
Customer ID:
P.O. Number:
Repair Station:
In Date:
Out Date:
Payment Type:
Payment Terms:
3/10/2016
BJ419
CRS LEGRO39G
03/05/2016
03/25/2016
Net 30-Open terms
Title: JEGE LLC
INVOICE SUMMARY FOR WORK ORDER NUMBER:
lime & Materials
Flat Rate
Total
Labor USD:
$94565.46
$75,096.37
4169,661.83
Parts USD:
$43.031.60
SOO)
$43,031.60
Services USD:
$10,411.04
SOO)
$10,411.04
Misc Charges USD:
$10,850.00
vassaao
Detail Subtotal USD:
$158,858.10
$75,096.37
$233,954.47
Freight USD:
4984.01
Subtotal USD:
5234.938.48
Funds on Deposit USD:
$75,000.00
Total USD:
SCHEDULED MAINTENANCE
FAR PART 91
LARRY VISOSKI
N212.1E
RE: PROPOSAL*
HAPP # 441M-529-21
$159,938.48
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 1 of 123
Printed: 321/2016 II:35:41AM
Rd: 322
EFTA00590796
Bill To: JEGE LLC
WO //:
Invoice Number
Item: 1
AIRFRAME Gulfst ream GIV
Team Manager.
Charles Hetwig
Customer Coordinator
Vinny Cicala
Part/Model n: GIV
AC Serial No./Tail No.: ■
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 1.1
RETURN TO SERVICE FOR GENERAL MAINTENANCE OR INSPECTION
Resolution: ACTT: 9208.4
ACTL: 4232
WORK ORDER NUMBER:
ITEM(S): I, 5, 6, 7, 11-27
THE MAINTENANCE LISTED ABOVE WAS PERFORMED IN ACCORDANCE WITH CURRENT FEDERAL
AVIATION REGULATIONS AND LS APPROVED FOR RETURN TO SERVICE WITH REGARDS TO THE
MAINTENANCE ACCOMPLISHED. FURTHER DETAILS ARE ON FILE AT THIS REPAIR STATION UNDER THE
ABOVE WORK ORDER. A COPY OF THLS WORK ORDER HAS BEEN PROVIDED TO THE OPERATOR
SIGNATURE:
Discrepancy: 1.2
Resolution:
ADVISE CUSTOMER OF PRESERVATION REQUIREMENTS PER ATA CHAPTER 10 OF THE RELEVANT
MAINTENANCE MANUALS FOR AIRFRAME, ENGINES, AND APU; REVIEW REQUIREMENTS IN
RELATION TO SCHEDULED DATE PROMISED AND LATER POTENTIAL DATE COMPLETED; AND
PERFORM MAINTENANCE OR PRESERVATION ACTIONS AS DIRECTED BY THE CUSTOMER AND
DOCUMENTED AS A WORK ORDER SQUAWK.
Step: 1.2.1
Open
SERVICE/ENGINE/APU
••" ADMINISTRATIVE ONLY •••
Step: 1.2.2
Open
AVIONICS SERVICE/AVIONICS INSTALL
••" ADMINISTRATIVE ONLY •••
Stem 1.2.3
Open
INTERIOR / WOOD / UPHOLSTERY / PAINT
••• ADMINISTRATIVE ONLY •••
Discrepancy: 1,3
Resolution:
ACCOMPLISH INBOUND/OUTBOUND INSPECTION
Step: 1.3.1
Completed
Step: 1.3.2
0 809
ACCOMPLISH INBOUND/PRELIMINARY INSPECTION FORM M-4
ACCOMPLISH OUTBOUND INSPECTION MAINTENANCE RELEASE
CHECKLIST S•17
Discrepancy: 1.4
ACCOMPLISH VIDEO OF AIRCRAFT, LS APPLICABLE, OTHERWISE N/A
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 2 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590797
Bill To: JEGE LLC
Resolution: ACCOMPLISHED VIDEO OF AIRCRAFT
WO N:
Invoice Number.
Discrepancy: IS
Resolution:
ACCOMPLISH PREFLIGHT INSPECTION IF REQUIRED
Discrepancy: 1.6
ACCOMPLISH INCOMING DEBRIEF TO INCLUDE THE INDUCTION / ARRIVAL BRIEF CHECKLIST -
CMP 010010
ChIP GIV 010010 SERVICE CENTER MAINTENANCE INDUCTION CHECKLIST
Resolution: Complied with CUP GIV 010010 Service Center Maintenance Induction Checklist
Step: 1.6.1
Completed
Step: 1.6.2
Completed
ACCOMPLISH 90 DAY DUELIST REVIEW IF REQUIRED
LIST OPERAT'OR'S AIRWORTHINESS REQUIREMENTS
Discrepancy: 1.7
Resolution:
TOOL CLEARANCE
Discrepancy: 1.8
COVER AND PROTECT AIRCRAFT
Resolution: ACCOMPLISHED COVER AND PROTECT OF THE AIRCRAFT INTERIOR AM) EXTERIOR. AS REQUIRED.
Discrepancy: 1.9
SERVICE TOILETAVASTE TANK
Resolution:
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 3 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590798
Bill To: JEGE LLC
WO if:
Invoice Number.
Discrepancy: 1.10
ASSIST CUSTOMER VITA ARRIVAL/DEPARTURE
Resolution: ACCOMPLISHED ASSISTANCE OF CUSTOMER WITH ARRIVAL AND DEPARTURE.
Discrepancy: 1.11
ACCOMPLISH HYDRAULIC FLUID SAMPLE AS REQUIRED
Resolution: ACCOMPLISHED HYDRAULIC FLUID CONTAMINATION CHECKS.
Discrepancy: 1.12
REMOVE AND SECURE CUSTOMER VALUABLES
Resolution: REMOVED AND SECURED CUSTOMER VALUABLES
Discrepancy: 1.13
FLUIDS/GASES (OIL, HYDRAULIC, OXYGEN, NITROGEN)
Resolution:
Discrepancy: 1.14
REVIEW LOGBOOK ENTRY PRIOR TO DEPARTURE
Resolution:
Discrepancy: LIS
ACCOMPLISH AIRCRAFT CLEANING
Resolution:
Services:
Ref. No.
Description
Quantity
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 4 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590799
Bill To: JEGE LLC
WO k:
Invoice Number.
Services:
Ref. No.
Description
Quantity
1.1511
AIRCRAFT CLEANING
1.1S 12
AIRCRAFT CLEANING
1.00
1.00
Discrepancy: 1.16
CONSUMABLES & SHOP SUPPLIES
Resolution:
Billing Method
Hours
Rate
Total
Misc Charges USD:
Time and Material
$5,000.00
Total USD:
$5,000.00
Miscellaneous Charge:
Ref. No.
Miscellaneous Charge
1.1611
CONSUMABLES & SHOP SUPPLIES
Step: 1.16.1
Open
CONSUMABLES
Amount USD
$5,000.00
Discrepancy: 1.17
CUSTONIER REQUESTTO INSPECT THE MAIN TIRES FOR WEAR.
Resolution:
Discrepancy: 1.18
CUSTOMER REPORTS THE k2 BRAKE LS LEAKING FLUID.
Resolution: REMOVED LEAKING #2 BRAKE ASSEMBLY WITH PIN 1159SCL204-61, MS NOV93-466. INSTALLED A
REPAIRED #2 BRAKE ASSEMBLY WITH PIN 1159SCL204-61, SIN NOV93-466. ALL WORK DONE IN
ACCORDANCE WITH GIV CMP 324105.
PERFORMED LEFT BRAKE BLEED AND EMERGENCY SYSTEM BLEED JAW GIV ChIP 324127 AND 324125.
PERFORMED WHEEL BRAKE - FUNCTIONAL TEST (BRAKE-BY-WIRE) IAW GIV GIMP 324101.
SEE STEPS BELOW FOR FURTHER DETAILS.
Billing Method
I lour.
Rate
Total
Labor USD:
Time and Material
ST
10.74
@
$132.00
$1,417.68
Labor USD:
Time and Material
OT
0.43
@
$198.00
$85.14
Total USD:
Services:
$1,502.82
Ref. No.
Description
Quantity
Sell Price USD
Extended USD
1.1812
GAC REPAIRS
Part Ref: 1159SC1204-61 BRAKE ASSEMBLY, MAIN GEAR 15 DEGREES
1.00
For detail description of the work complied with see the Work Order Detail report.
$0.00
$0.00
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 5 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590800
Bill To: JEGE LLC
WO 9:
Invoice Number:
Step: 1.18.1
Completed
CLEANED THE BRAKE TO INVESTAGATE THE LEAK. APPLIED
HYDRAULICS AND APPLIED BRAKES SEVERAL TIMES, SET PARKING
BRAKE, AND ALLOWED THE BRAKE TO HAVE PRESSURE ON IT OVER
NIGHT. NOTICED HYDRAULIC FLUID LEAKING FROM THE UPPER AFT
PLSTON RETAINER. REMOVED THE LEAKING BRAKE P/N 90000420-1 S/N
NOV93-466. WORK DONE IAW GULFSTREAM G IV CMP 324105.
Step: 1.18.2
Completed
CLEANED AND REPACKED WHEEL BEARINGS ON NUMBER 2 MIA: WHEEL
ASSY. WORK DONE IAW CIV CMP 324052
Step: 1.18.3
Completed
INSTALLED WHEEL BEARINGS IN 82 AMC WHEEL ASSY IAW GIV CA1P 324052
Step: 1.18.4
Completed
REMOVED LEAKING 82 BRAKE: ASSEMBLY WITH P/N 1159SCI.204-61, SIN
NOV93-466. INSTALLED A REPAIRED 02 BRAKE ASSEMBLY WITH P/N
1159SCL204-61.S/N NOV93-466. REFERENCE 8130-3 WITH FORM TRACKING
20160315033032 DATED 15 MAR 2016 FROM GAC SAV CRS/ GR4R216M. ALL
WORK DONE IN ACCORDANCE WITH GIV CMP 324105.
Step: 1.18.5
Completed
PERFORMED LEFT BRAKE BLEED AND EMERGENCY SYSTEM BLEED IAW
Step: 1.18.6
Completed
GIV CMP 324127 AND 324125. SEE THS WORK ORDER ITEM 1.24 FOR
FURTHER DETAILS,
PERFORMED WHEEL BRAKE - FUNCTIONAL TEST (BRAKE-BY-WIRE) IAW
GIV CMP 324101.
Discrepancy: 1.19
CUSTOMER REPORTS THAT PRESSURIZATION SYSTEM INOP IN AUTO MODE WORKS IN MANUAL
MODE
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
11.54
@
$132.00
$1,523.28
Misc Charges USD:
Time and Material
$5,850.00
Total USD:
$7,373.28
Miscellaneous Charge:
Ref. No.
Miscellaneous Charge
Amount USD
1.1911
Customer Supplied Part Charge
$5,850.00
Step: 1.19.1
Completed
ACCESSED CABIN PRESSURE TRANSDUCER TEST SWITCH. FOUND LIGHT
TO NOT ILLUMINATE WHEN PRESSED OR TEST SWITCH PLACED INTO
MULTIPLE POSITIONS. RESEARCHED WIRING DRAWINGS. CHECKED 115
VAC AT CABIN AIR PRESSURE TRANSDUCER 47FL IPI PIN 31 WITH NO
DEFECTS NOTED. GROUND PRESENT AT 47FLIPI PIN 30. CONTACTED
LUCAS FROM GAC SAV TECH OPS. FAILED CABIN PRESSURE TRANSDUCER
P/N: 2100136-1-10
WORK PERFORMED IAW GULFSTREAM GIV
WIRING DWG CABIN PRESSURE CONTROL 21.31-00.
Step: 1.19.2
I'omplcted
PERFORMED PRESSURIZATION SYSTEM TEST IAW GULFSTREAM
Dt )CUMENT NO. I159SER86-043, REV. C, DATED 10-30-01 TITLED "OPERATING
INS'T'RUCTIONS PRESSURIZATION TEST UNIT" AND CONFIRMED CABIN
PRESSURE TRANSDUCER P/N 64547-2100136-1-10,
IS FAULTY.
Discrepancy: 1.20
Resolution:
Pans:
Ref. No.
REPLACE CABIN PREASURE RELIEF VALVE
Part number:
Description
Quantity
12011
103568-1-2MR4
VALVE. CABIN PRESSURE SAFETY
1
RELIEF
1.2012
MS29512-06
O-RING. TUBE FITTING PACKING
1
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 6 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590801
Bill To: JEGE LLC
Pans:
Ref. No.
Pan number:
WO U:
Description
Invoice Number.
Quantity
1.20 13
M528778-6
PACKING, PREFORMED TUBE
1
FITTING
1.20 #4
MS23775-110
SEAL
1
1.20#5
MS29512-06
0 -RING, TUBE FITTING PACKING
1
1.20 #6
M528778-6
PACKING, PREFORMED TUBE
1
FITTING
1.20 #7
MS28775-110
SEAL
1
1.20 #8
NAS6603-4
BOLT-HEX HEAD. CLOSE
2
TOLERANCE
Step: 1.20.1
Completed
REMOVED CABIN PRESSURIZATION SAFETY VALVE PN 103568-1-1 SN 55-627.
INSTALLED A REPAIRED CABIN PRESSURIZATION SAFETY VALVE PN
103568-1-2MR4 SN 90-353. RECEIVED FROM HONEYWELL INTERNATIONAL
INC. REFERENCE 8130-3 TRACKING NUMBER 301479130 APPROVAL NUMBER
HZ3R571L DATED APR/2212008. WORK PERFORMED IAW G1V CMP 213080
STEPS A-D(9). NEEDS OPS AND LK CHECK
Step: 1.20.2
( onpleted
PERFORNIED GULFSTREAM GIV CMP CODE 245051 - ACMC POWER
DISTRIBUTION SYSTEM - FUNCTIONAL TEST, USING BATTERIES UP TO TRU
POWER SOURCES. ( PROCEDURE B1 TO B51
Step: 1.20.3
In Progress
NEED APU AND ENGINE RUN
Step: 1.20.4
Open
OPEN
Discrepancy: 1.21
CHANGE #3 MAIN TIRE.
Resolution: REMOVED WHEEL ASSEMBLY WITH PIN 5008447.3, S/N JUL-91-249. INSTALLED A REPAIRED WHEEL
ASSEMBLY WITH PIN 1159SCL203-45, S/N JUL-91-249/S-JAN07-134. REFERENCE FAA FORM 8130-3 WITH
FORM TRACKING #GAW-05126 DATED 19/MAR/2016 FROM GULSTREAM CRSLEGRO39G. ALL WORK DONE
IN ACCORDANCE WITH GIV CMP 324013,324043,324111,324038. UPDATED CMP CODES
324013,324043,324111,324038 AS REQUIRED.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
16.28
@
$132.00
$2,148.96
Pans USD:
Time and Material
$1,575.19
Total USD:
$3,724.15
Parts:
Ref. No.
Pan number:
Description
Quantity
Sell price USD
Extended USD
1.21 #1
1159SC1,206-33
TIRE, MAIN
1
81,540-50
$1,540.50
1.21 #2
MS28775-383
PACKING
1
$16.05
$16.05
1.21 #3
515X333-20Z
2 OZ TOUCHUP KIT, GREEN EPDXY
1
$18.64
$18.64
PRIMER
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 7 of 123
Printed: 321/2016 11:35:41AM
Rd: 322
EFTA00590802
Bill To: JEGE LLC
WO N:
Invoice Number:
Step: 1.21.1
Completed
DISMOUNTED TIRE #3 MEG WHEEL AS.SY IAW GIV CMP 324043
Step: 1.21.2
Completed
REPLACED CLIP WITH P/N 5008897. NO S/N.. REFERENCE PACKING SLIP
WITH ENTERPRISE TRANSFER NUMBER 000666648 DATED 03/1812016 FROM
GULFSTREAM.. REPLACED COTTER PINS (2) WITH P/N MS9245-22 NO SIN.
REFERENCE PACKING SLIP WITH ENTERPRISE TRANSFER NUMBER
000666642 DATED 03/18/2016 FROM GULFSTREAM. REPLACED PACKING P/N
hLS28775-383 NO S/N. REFERENCE PACKING SLIP WITH ENTERPRISE
TRANSFER NUMBER 000334467 DATED 10/19/2011 FROM GULFSTREAM.
REMOVED CORRODED FLANGE WITH P/N 5004909 SIN JUL-91-249.
INSTALLED NEW FLANGE WITH P/N 5004909 S/N S-JAN07-134. REFERENCE
FAA FORM 8130-3 WITH FORM TRACKING NUMBER 20070202050602 FROM
GULFSTREAM AEROSPACE CORPORATION APPROVAL/AUTHORIZATION
NO: ODARFI00127CE DATED FEB 02,2007. REMOVED WORN TIRE 34X9.25-16
WITH P/N 348F83-2 S/N 31762073. INSTALLED NEW TIRE 34X9.25-16 WITH PIN
348F83-2 SIN 60971719. REFERENCE FAA FORM 8130-3 WITH FOR.NI TRACKING
NUMBER 57783052-001 FROM GOODYEAR TIRE AND RUBBER CO.
APPROVAIJAUTHORIZATION NO: DARF510258CE DATED APR/2U2006.
REMOVED CORRODED FLANGE RETAINING RING P/N 5012120 NO S/N.
INSTALLED NEW FLANGE RETAINING RING P/N 5012120 NO S/N. REFERENCE
CERTIFICATE OF CONFORMANCE DATED MAY 19, 2007 FROM AIRCRAFT
BRAKING SYSTEMS CORPORATION, CERTIFICATE NO. 80446289-10. ALL
WORK DONE IAW GIV AMM 3242-00. FORWARDED PAPERWORK TO
INSPECTION FOR ISSUANCE OF FAA FORM 8130-3.
WHEEL ASSEhIBLY P/N: 5008447-3. SERIAL NUMBER IS NOW:
JUL -91-249/S-JAN07-134
Step: 1.21.3
Completed
COMPLIED WITH ChIP GIV 324053 MAIN WHEEL BEARINGS (RIGHT
INBOARD NO. 3)- INSPECTION PACK (AIRCRAFT BRAKING SYSTEM)
Step: 1.21.4
Completed
COMPLIED WITH ChIP GIV 324111 WHEEL BRAKE (RIGHT INBOARD NO. 3)-
INSPECTION (ABS)
Step: 1.21.5
Completed
COMPLIED WITH CHIP GIV 324038 TIRE-SERVICING
Discrepancy: 1.22
OVERTIME APPPROVAL TO MEET THE CUSTOMERS OUT DATE.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Flat Rate
53,000.00
Total USD:
$3,000.00
Discrepancy: 1.23
DURING #3 TIRE CHANGE FOUND CORROSION ON DEMOUNTING RIM AND RETAINING RING.
Resolution: ACCOMPLISHED REPLACEMENT OF THE RETAINING RING, AND OUTER FLANGE, DUE TO CORROSION.
WHEEL ASSEMBLY PIN: 5008447-3, SERIAL NUMBER IS NOW: JUL-91-249/S-JAN07-134.
REF: GULFSTREAM BAF, CRS# LEGR039G FAA FORM 8130-3 WITH FORM TRACKING # GAW-05126, DATED
3/19/2016.
REF: SQUAWK 1.21 FOR INSTALLATION OF THE WHEEL ASSEMBLY, AND STEPS 1.23.1 - 1.23.2 BELOW FOR
MORE DETAILS
Billing Method
Hours
Rate
Total
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 8 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 322
EFTA00590803
Bill To: JEGE LLC
Labor USD:
Labor USD:
Parts USD:
Total USD:
Parts:
Ref. No.
Time and Material
Time and Material
Time and Material
Part number:
ST
OT
Description
COTTER PIN
FIANCE
PACKING
CLIP
RING
WO 0:
Invoice Number:
2.28
0
$132.00
0.17
0
$198.00
$300.96
$33.66
$7,375.70
$7,710.32
Quantity
Sell price USD
Extended USD
1.2311
1.2312
1.2313
1.2315
1.2316
Step: 1.23.1
Step: 1.23.2
MS9245-22
5004909
MS28775-383
5008897
501212(1
Completed
Completed
10
$0.78
1
$5,829.88
1
$16.05
1
$119.13
1
$1,402.84
COMPLIED WITH CHIP GIV 324053 MAIN WHEEL BEARINGS (RIGHT
INBOARD NO. 3)- INSPECTION PACK (AIRCRAFT BRAKING SYSTEM)
REPLACED CLIP WITH P/N 5008897, NO S/N.. REFERENCE PACKING SLIP
WITH ENTERPRISE TRANSFER NUMBER 000666648 DATED 03/18/2016 FROM
GULFSTREAM.. REPLACED COTTER PINS (2) WITH P/N MS9245-22 NO S/N.
REFERENCE PACKING SLIP WITH ENTERPRISE TRANSFER NUMBER
000666612 DATED 03/18(2016 FROM GULFSTREAM. REPLACED PACKING P/N
MS28775-383 NO SM. REFERENCE PACKING SLIP WITH ENTERPRISE
TRANSFER NUMBER 000334467 DATED 10(1912011 FROM GULFSTREAM.
REMOVED CORRODED FLANGE WITH P/N 5004909 SIN JUL-91-249.
INSTALLED NEW FLANGE WITH P/N 5004909 S/N S-JAN07-134. REFERENCE
FAA FORM 8130-3 WITH FORM TRACKING NUMBER 20070202050602 FROM
GULFSTREAM AEROSPACE CORPORATION APPROVAL/AUTHORIZATION
NO: ODARFI00127CE DATED FEB 02,2007. REMOVED WORN TIRE 34X925-16
WITH P/N 348F83-2 S/N 31762073. INSTALLED NEW TIRE 34X9.25-16 WITH P/N
.118F83-2 SIN 60971719. REFERENCE FAA FORM 8130-3 WITH FORM TRACKING
NUMBER 57783052-001 FROM GOODYEAR TIRE AND RUBBER CO.
APPROVAIJAUTHORIZATION NO: DARF510258CE DATED APFU2U2006.
REMOVED CORRODED FIANCE RETAINING RING P/N 5012120 NO S/N.
INSTALLED NEW FLANGE RETAINING RING P/N 5012120 NO S/N. REFERENCE
CERTIFICATE OF CONFORMANCE DATED MAY 19, 2007 FROM AIRCRAFT
BRAKING SYSTEMS CORPORATION, CERTIFICATE NO.80446289-10. ALL
WORK DONE IAN' GIV AMM 32-42-00. FORWARDED PAPERWORK TO
INSPECTION FOR ISSUANCE OF FAA FORM 8130-3.
IVHEELASSEhIBLY P/N: 5008447-3, SERIAL NUMBER IS NOW:
JUL.-91-249/S-JAN07-131
$7.80
$5,829.88
$16.05
$119.13
$1,402.84
Discrepancy: 1.24
WHILE C/W 02 BRAKE CHANGE IT WAS NOTED THAT LH BRAKES WOULD ONLY REACH 1200
PSI(SHOULD BE 2750-3000 PSI)
Resolution: WHILE TROUBLESHOOTING LAI BRAKE ISSUE SWAPPED THE Lill BRAKE PRESSURE TRANSMITTER
P/N:1159SCH240-7, S.01:HAL0188, WITH THE R/H PRESSURE TRANSMITTER PIN:1159SCH240-5,SIN:4723-1-229
AND FOUND THAT THE ISSUE FOLLOWED THE 1/11 TRANSMITTER. SWAPPED TRANSMITTERS BACK.
REMOVED MALFUNCTIONING IJII BRAKE PRESSURE TRANSMITTER P/N:1159SCH240-7,S/N:HAL0H38.
INSTALLED INSPECTED BRAKE PRESSURE TRANSMITTER P/N:1159SCH240-7, S/N:HAL1654. PART
RECEIVED FROM AUXITROL SA, CERTIFICATE NUMBER: FR.145.023. REFERENCE ELSA FORM I WITH
FORM TRACKING NUMBER:201354009, DATED 29.NOV.2013. ALL WORK DONE IAW GIV CMP 324145 BRAKE
PRESSURE TRANSMITTER (LEFT) - REMOVAL / INSTALLATION. OPS AND LEAK CHECK GOOD.
PERFORMED GIV CMPS 324125, 324126, & 324127 LEFT, RIGHT & EMERGENCY BRAKE BLEED SERVICE
Labor USD:
Labor USD:
Parts USD:
Billing Method
Hours
Time and Material
Time and Material
Time and Material
ST
OT
Rate
Total
5.12
O
$132.00
1.00
@
$198.00
For detail description of the work complied will, see the Work Order Detail report.
$675.84
$198.00
$0.78
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 9 of 123
Printed: 3/21/2016 II:35:41AM
Itc.322
EFTA00590804
Bill To: JEGE LLC
WO tl:
Invoice Number.
Total USD:
$874.62
Parts:
Ref. No.
Pan nuniber.
Description
Quantity
Sell price USD
Extended USD
1.24 41
1159SCH240-7
TRANSDUCER. PRESSURE.
I
$0.00
$0.00
HYDRAULIC
1.2412
NASI612-4A
SEAL. 0.250 INCH OD TUBING
I
$0.18
$0.78
Item: 5
TECHNICAL BULLETIN'S (ASC,CB,ACB,AD,SB)
Team Manager.
Charles Ilelwig
Customer Coordinator:
Many Cicala
Pari/Model
AC Serial No/Tit No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 5.1
CMP GIV 982270 CB 227 OXYGEN (ATA 35), REPLACEMENT - OXYGEN SYSTEM FLEXIBLE HOSES, PN
02C20T1
THIS CUSTOMER BULLETIN (CB 227) ISA ONE-TIME ACTION TO REPLACE ALL EXISTING PART
NUMBER 02C20T1 OXYGEN SYSTEM FLEXIBLE HOSES WITH PART NUMBER 37009 OXYGEN
SYSTEM FLEXIBLE HOSES.
EFFECTIVITY: AIRCRAFT SERIAL NUMBERS 1000 THROUGH 1499.
NOTES:
ESTIMATED LABOR INCLUDES ACCESS TO THE AFFECTED OXYGEN SYSTEM DROPDOWN BOX
FLEXIBLE HOSES. THIS INCLUDES ACCESS TO OXYGEN DROP-DOWN BOXES LOCATED IN
PERSONAL SERVICES UNITS (PSUS), AS WELL AS REMOVAL AND REINSTALLATION OF
HEADLINERS IN THE VESTIBULE, FORWARD GALLEY, FORWARD LAVATORY, CREW REST, AFT
GALLEY, OR AFT LAVATORY AS NECESSARY, AND INCLUDES ACCESS TO THE THERAPEUTIC
OXYGEN SYSTEM.
THE QUOTED PRICE DOES NOT INCLUDE REMOVAL OF ANY CABINETRY, CABIN FURNITURE OR
CABIN COMPARTMENT DIVIDERS.
RE: PROPOSAL,/
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 10 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590805
Bill To: JEGE LLC
WO 4:
Invoice Number:
Discrepancy: 5.2
CMP GIV 982321 CB 232A - MODIFICATION - AIRCRAFT MAIN BATTERY CHARGERS
THIS CUSTOMER BULLETIN (CB 232A) IS A ONE-TIME ACTION TO INCORPORATE ELDEC SERVICE
BULLETIN 8-842-24-02.
EFFECTIVITY: ALL GIV AIRCRAFT HAVING PART NUMBER 1159SCAV520 SERIES BATTERY
CHARGERS
NOTES:
THIS CUSTOMER BULLETIN IS A MANAGED PROGRAM AND MUST BE ACCOMPLISHED AT A
GULFSTREAM AEROSPACE AUTHORIZED FACILITY. THIS CUSTOMER BULLETIN MUST BE
COORDINATED THROUGH THE GULFSTREAM PROGRAM OFFICE VIA EMAIL AT
OR BY CALLING GULFSTREASI SCHEDULING AT 800-810-GULF
(4853), OR
IF NOT SCHEDULED, DOWN TIMES COULD INCREASE SIGNIFICANTLY.
11595CAV520-5 BATTERY CHARGERS WITHIN (SPARES WARRANTY) WILL BE MODIFIED FREE OF
CHARGE TO 1159SB57520-11 OR MAY BE REPLACED WITH 1159SCAV520-7. OPERATORS CHOOSING
TO REPLACE THE 1159SCAV520-5 WITH 1159SCAV520-7 WILL INCUR ADDITIONAL COSTS.
MATERIALS WILL BE BILLED, AS REQUIRED.
RE: PROPOSAL,/
*" NOT APPLICABLE TO THIS AIRCRAFT PER EQUIPMENT INSTALLED ***
Resolution: CUSTOMER ELECTS NO ACTION AT THIS TIME.
Discrepancy: 53
CMP GIV 982350 CB 235 - REPLACEMENT - MAIN LANDING GEAR DOOR ACTUATOR END CAP - LIFE
LIMIT
THIS CUSTOMER BULLETIN IS A ONE-TIME ACTION TO REPLACE ALL MAIN LANDING GEAR DOOR
ACTUATORS THAT HAVE BEEN IDENTIFIED PER CB 234 AS HAVING 9,500 CYCLES SINCE NEW (CSN)
OR GREATER AND ALL MAIN LANDING GEAR DOOR ACTUATORS FOR WHICH CSN CANNOT BE
DETERMINED.
EFFECTIVITY: ALL GIV AIRCRAFT
COMPLIANCE: COMPLIANCE WITH THIS CUSTOMER BULLETIN IS REQUIRED WITHIN TWELVE
(12) MONTHS FROM THE ORIGINAL ISSUE DATE OF 01 JULY 2015.
NOTES:
.1 CONTACT GULFSTREAM REPAIR CONTROL AT
OR •
OPTION 1, THEN OPTION 3 FOR ACTUATOR RENTAL/ EXCHANGE AVAILABILITY AND
REPAIR SCHEDULE PRIOR TO REMOVING ACTUATOR(S) FROM THE AIRCRAFT.
11 THIS CUSTOMER BULLETIN IS A MANAGED PROGRAM AND MUST BE SCHEDULED THROUGH
GULFSTREAM REPAIR CONTROL. GULFSTREAM WILL MANAGE A LIMITED COMPONENT RENTAL
/ EXCHANGE POOL. OPERATORS PERFORMING THIS CUSTOMER BULLETIN MAY ELECT TO
UTILIZE THE RENTAL/ EXCHANGE POOL WHILE THE END CAPS ON THEIR ORIGINAL
COMPONENTS ARE REPLACED. DUE TO A LIMITED AVAILABILITY OF ASSETS, FAILURE TO
SCHEDULE COULD RESULT IN SIGNIFICANTLY INCREASED DOWNTIME.
RE: PROPOSAL,/
)-2S
*** LABOR ONLY
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description or the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page II of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590806
Bill To: JEGE LLC
WO #:
Invoice Number.
Item: 6
AVIONICS
Team Manager.
Charles Helwig
Customer Coordinator.
Vinny Cicala
Pan/Model a:
AC Serial
No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 6.1
CUSTOMER REPORTS #1 TRANSPONDER LOOSES ATC ALTITUDE READ OUT AFTER ONE HOUR.
Resolution: UNSEATED ATC NO.1 PN: 622-9210409 SN: 2376. PERFORMED VISUAL INSPECTION OF BOTH RACK AND
COMPONENT INSURING NO BENT OR PUSH PINS ARE PRESENT. CLEANED CONTACTORS AND RESEATED
ATC NO.1 PN: 622-9210-409 SN: 2376. GAINED ACCESS TO AND DISCONNECTED INTERCONNECT FOR ATC
NO.1 AND FOUND MALE PINS S AND T TO BE BENT AND MAKING LIMITED CONTACT WITH FEMALE PINS
IN ACCORDANCE WITH WIRING DIAGRAM 1159SB4148I, GIV AMM 34-02-04 AND GIV WIRING DIAGRAM
34-55-00. REMOVED ATC NO.2 P/N:622-9210-409 S/N: 1G8M. UNSECURED ATC RACKS TO FASCILITATE
MAINTENANCE. REMOVED ATC NO.1 DISCONNECT CONNECTORS P/N: NtS3120F22-55P SN: UNK AND P/N:
MS3I26F22-55S SN: UNK. INSTALLED NEW CONNECTORS P/N: N1S3120F22-55P SN: UNK AND P/N:
MS3126F22-5SS SN: UNK. RECEIVED P/N: NIS3120F22-55P FROM ELECTRO ENTERPRISE REFERENCE
CERTIFICATE OF CONFORMANCE ON PACKSLIP NO: 1779462 DATED 03/14/2016. RECEIVED
P/N:MS3126F22-55S FROM ELECTRO ENTERPRISES REFERENCE CERTIFICATE OF CONFORMANCE WITH
INVOICE NO: 1156087 DATED 05/25/11. PERFORMED WIRING RING OUT CHECK OF ATC NO.1
TRANSPONDER LAW WESTERN COMMANDER WIRING DWG NO:08069197 FOUND GOOD. REINSTALLED
SERVICABLE ATC NO.1 PN: 622-9210-409 SN: 2376 AND SERVICEABLE ATC NO.2 P/N:622-9210-409 S/N: IG8N1
AND PERFORMED ATC FUNCTIONAL CIIECKS IN ACCORDANCE WITH GIV AMM 34-02-04. NOTED NO
FURTHER ISSUES AT THIS TIME SEE STEPS FOR DETAILS.
Billing Method
Hours
Rate
Total
Labor USD:
Parts USD:
Total USD:
Parts:
Ref. No.
Time and Material
Time and Material
Part number:
ST
39.91
iD
$132.00
Description
$5,268.12
$211.08
Extended USD
Quantity
$5.479.20
Sell price USD
6.1 al
NIS31201122-5SP
CONNECTOR
1
$95.68
$95.68
6.112
NIS31261122-5SS
CONNECTOR
I
$115.36
$85.36
6.1 #3
686DM5
SLEEVE. BRAIDED 1/2 BLACK
2
$3.92
$7.84
EXPAND()
6.1 #4
SPT.S0
SPIRAL WRAP TEFLON 1/2"
2
$3.30
$6.60
NATURAL
6.1 #5
TY2.551
TYRAP, WHITE
10
$0.78
$7.80
6.1 #6
TY242M
TIE, CABLE; NYLON 8.19 IN.; 0.14
10
$0.78
$7.80
IN.; 30 LB. TENSILE STRENGTH
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 12 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 322
EFTA00590807
Bill To: JEGE LLC
WO 8:
Invoice Number:
Step: 6.1.1
Completed
APPLIED POWER TO AIRCRAFT. MONITORED ALTITUDE REPORTING ON
BOTH ATC TRANSPONDERS USING ATC 600 TEST SET FOUND GOOD. LET IT
RUN FOR A LONG TIME, WHILE PERFORMING ASCB BUS SWEEP (REF.
SQUAWK 6.5), FOUND GOOD AT THLS TIME. WORK WAS DONE REFERENCE
CIV A.,M.M. 34-02-04.
Step: 6.11
Completed
UNSEATED ATC NO.1 PN: 622-9210-409 SN: 2376. PERFORMED VISUAL
INSPECTION OF BOTH RACK AND COMPONENT INSURING NO BENT OR
PUSH PINS ARE PRESENT. CLEANED CONTACTORS AND RFSEATED ATC
NO.1 PN: 622-9210-409 SN: 2376. GAINED ACCESS TO AND DISCONNECTED
INTERCONNECT FOR ATC NO.1 AND FOUND MALE PINS S AND T TO BE BENT
AND MAKING LIMITED CONTACT WITH FEMALE PINS. STRAIGHTENED
PINS AND RECONNECTED DISCONNECT. APPLIED POWER TO AIRCRAFT
AND PERFORMED MULTIPLE CHECKS OF ATC SYSTEM USING IFR 6000.
NOTED NO OCCURENCF:S OF TRANSPONDER FAILING TO REPORT
ALTITUDE. ALL WORK PERFORMED IN ACCORDANCE WITH GIV AMM
.14-0244 AND WIRING DIAGRAM 1159SB41481.
Step: 6.13
Completed
STEP ENTERED IN ERROR
Step: 6.1.4
Completed
CONDUCTED RESEARCH TO FIND PART NUMBER FOR ATC TRANSPONDER
INTERCONNECT CANNON PLUG PART NO. PART NUMBER FOR RECEPTACLE
LS M.S3120F22-55P PART NUMBER FOR PLUG IS MS3126F122-55S. REFERENCE
WESTERN COMMANDER DRAWING NO. 08069197, TITLED NO. 1
TRANSPONDER (MOD) NO REV, DATED 5/12/89. THIS CONNECTOR CONTAINS
VARIOUS 429 DATA INPUTS/OUTPUTS. FOR CONTROL AND TUNING.
SUPPRESSION SIGNALS AND TCAS INTERFACE. AND POWER. ALL WORK
PERFORMED IN ACCORDANCE WITH WESTERN COMMANDER DRAWING
NO. 08069197, TITLED NO. I TRANSPONDER (MOD) NO REV, DATED 5/12/89
Step: 6.1.5
Completed
REMOVED ATC NO2 P/N:622-9210-409 S/N: IG8M. UNSECURED ATC RACKS
TO FASCILITATE MAINTENANCE. REMOVED ATC NO.1 DISCONNECT
CONNECTORS P/N: MS3120F22-55P SN: UNK AND P/N: MS3126F22-55S SN: UNK.
INSTALLED NEW CONNECTORS P/N: M.S3120F7.2-55P SN: UNK AND P/N:
RIS3126F27.-55S SN: UNK. RECEIVED P/N: fILS3120F'22-55P FROM ELECTRO
ENTERPRISE REFERENCE CERTIFICATE OF CONFORMANCE ON PACKSLIP
NO: 1779462 DATED 03/14/2016. RECEIVED P/N:NIS3126F22-55S FROM
ELECTRO ENTERPRISES REFERENCE CERTIFICATE OF CONFORMANCE
WITH INVOICE NO: 1156087 DATED 05/25/11. ALL WORK PERFORMED IN
ACCORDANCE WITH WIRING DIAGRAM 115981141481, GIV AMM 34-02-04 AND
GIV WIRING DIAGRAM 34-55-00.
Step: 6.1.6
Completed
PERFORMED WIRING RING OUT CHECK OFATC NO.1 TRANSPONDER IAW
WESTERN COMMANDER WIRING DWG NO:08069197 FOUND GOOD.
Discrepancy: 6.2
CUSTOMER REQUEST TO EXCHANGE THE 82 COM STICKY COM SELECTOR TO CHANGE
FREQUENCY.
Resolution: APPLIED POWER AIRCRAFT, CHECKED OPERATION OF NO. 2 RADIO TUNING UNIT (RTU), SQUAWK
CONFIRMED, FOUND LINE SELECT KEY (1R) IS INTERMITTENT (STICKY) TO CHANGE FREQUENCY.
REMOVED RTU NO:2 P/N:822-0836-035 S/N: 267 FOR REPAIR. RECEIVED OK TO INSTALL AND INSTALLED
REPAIRED RTU NO:2 P/N:822-0836-035 S/N: 267 IN ACCORDANCE WITH GIV CMP232336. RECEIVED UNIT
FROM ROCKWELL COLLINS REFERENCE 8130-3 WITH FORM TRACKING NO: /05121875 WORK ORDER:
WEP016-01211 CERT: ED7Y210Y DATED 16hIAR2016. PERFORMED VHF COMMUNICATIONS SYSTEM -
OPERATIONAL CHECK IN ACCORDANCE WITH CIV AMM 23-01-00,MARKER BEACON SYSTEM -
OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 34-02-02, NAVIGATION / DISTANCE MEASURING
EQUIPMENT SYSTEMS - OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM 34-02-02, AUTOMATIC
DIRECTION FINDING SYSTEM - OPERATIONAL CHECK IN ACCORDANCE WITH GIV ANEW 34-02-03,
ELECTRIC POWER MONITOR PANEL LIGHT EMITTING DIODE - REPLACEMENT, IN ACCORDANCE WITH
GIV ANEW 24-03-02
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
7.48
@
$132.00
5987.36
Services USD:
Time and Material
51,500.00
Total USD:
52,487.36
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 13 of 123
Printed: 3/21/2016 II:35:41AM
Rd: 322
EFTA00590808
Bill To: JEGE LLC
Services:
WO N:
Invoice Number.
Ref. No.
Description
Quantity
Sell Price USD
Extended USD
6.2411
GAC REPAIRS
1.00
$1,500.00
$1,500.00
Step: 6.2.1
Completed
APPLIED POWER AIRCRAFT, CHECKED OPERATION OF NO.2 RADIO
TUNING UNIT (RTU), SQUAWK CONFIRMED, FOUND LINE SELECT KEY (IR)
LS INTERMITTENT (STICKY) TO CHANGE FREQUENCY.
NEED TO REPLACED OR SEND FOR REPAIR REV NO.2.
Discrepancy: 63
CUSTOMER REPORTS TIIE #2 HF RADIO WILL NOT TUNE ("Cr' AND "RT" LIGHT ILLUMINATES).
Resolution: NO.2 HF SYSTEM WITH "CP" LIGHT ILLUMINATED AND WITH FAULT 08
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
4.48
Q
$132.00
$59136
Total USD:
$591.36
Step: 6.3.1
Step: 6.3.2
Completed
APPLIED POWER TO AIRCRAFT, PERFORMED HF NO. I AND NO.2 SYSTEM
OPERATIONAL TEST, FOUND NO.2 HF SYSTEM WITH "Cr' LIGHT
ILLUMINATED AND WITH FAULT 08. ASKED CUSTOMER ABOUT THE HF
SQUAWK DUE TO HFSYSTEM NO. 1 15 THE ONE FAILED ON THE ITEM. PER
CUSTOMER, HE IS NOT SURE WHAT SYSTEM IS FAILING. GAIN ACCESS ON
TAIL COMPARTMENT, VLSUALLY INSPECTED THE HF COUPLERS AND HF
TRANSCEIVERS, FOUND THE RF COAX CONNECTOR ON HF COUPLER NO.2
IS LOO-SE. SECURED COAX CONNECTOR ON HF COUPLER NO.2.
PERFORMED HIGH FREQUENCY COMMUNICATION SYSTEMS NO. 1 AND
NO.2 - OPERATIONALTEST, CHECKED GOOD ON BOTH SYTEM. WORK
DONE IAW GULFSTREAM GIV MM ATA 23-03-00.
Completed
USING 0-15 PSIG PRESSURE GAUGE, CHECKED THE PRESSURE IN BOTH NO.
I AND NO.2 HF COUPLERS. NO. 1 COUPLER WAS AT 7 PSI AND NO.2
COUPLER WAS AT APPX. 6.75 PSI. BOTH OF THESE READINGS ARE WITHIN
ALLOWABLE PRESSURES AS PER GIVI=.
23-0340. HIGH FREQUENCY
COMMUNICATION COUPLER - SERVICING.
Discrepancy: 6.4
CUSTOMER REPORTS THE FMS SELECTOR SWITCH NEEDS TO BE CHANGED (1/2 FMS SELECTOR
ON CENTER PEDESTAL).
Resolution: CONFIRMED CENTER FMS SELECTOR WILL ONLY BRIEFLY ILLUMINATE 1/2 FMS. REMOVED AND
CAPSULE AND REMOVED 4 EA. DEFECTIVE LAMPS P/N OL-3335, NO SERIAL NOS. REPLACED WITH 4 EA
NEW LAMPS P/N: OL-3335 FROM GAC WESTFIELD STOCK. PERFORMED OPERATIONAL CHECK OF
SWITCHES IN ACCORDANCE WITH GIV AMM 33-01.00 ANNUNCIATOR LIGHT - OPERATIONAL TEST, WITH
NO DISCREPANCIES.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
6.71
@
$132.00
$885.72
Pans USD:
Time and Material
$360.50
Total USD:
$1,246.22
Parts:
Ref. No.
Pan number:
Description
Quantity
Sell price USD
Extended USD
6.4411
OL3335
LAMP
4
$5.15
$20.60
6.402
P9.212
SWITCH
1
$339.90
$339.90
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 14 of 123
Printed: 321/2016 II:35:41AM
Rd: 322
EFTA00590809
Bill To: JEGE LLC
Step: 6.4.1
Step: 6.4.2
WO If:
Invoice Number.
Completed
GAINED ACCES TO THE FMS SELECTOR SWITCH (1/2 FMS) ON PEDESTAL
REMOVED DEFECTIVE SWITCH (1./2 FhIS) P/N: 99-212 FROM ASSEMBLY.
RECEIVED OK TO INSTALL AND INSTALLED A NEW SWITCH P/N: 99-212
THAT WAS RECEIVED FROM GAC-SAVANNAH WITH SHIPMENT NO.:
SASH316-3O02, ENTERPRISE TRANSFER NO.: 000663760, DATED 03/08/2016 TO
THE ( 1/2 FMS) SWITCH POSITION ON ASSEMBLY. SECURED SWITCH
ASSEMBLY TO PEDESTAL. WORK WAS DONE WITH REFERENCE TO THE
JET CENTER DRAWING NO. 08069100, TITLED NO. 3 FMS, DATED 3-1148.
Completed
PERFORMED OPERATIONAL CHECK IN ACCORDANCE WITH GIV AMM
33-01-00 ANNUNCIATOR LIGHTS - OPERATIONAL TEST, WITH NO
DISCREPANCIES.
Discrepancy: 6.5
CUSTOMER REQUESTS ASCB SWEEP
Resolution: PERFORMED ASCB BUS SWEEP IAW GI V=.
31-02-00. FOUND THAT THERE WERE NUMEROUS BUS
COUPLER CONNECTIONS THAT REQUIRED CLEANING (NOTICED SIGNAL FLUCTUATION ON
OSCILLOSCOPE). CLEANED BUS COUPLER CONNECTIONS AS REQUIRED AND SECURED ALL
CONNECTIONS. PERFORMED OPS CHECK AND FINAL ASCB BUS SWEEP IN ACCORDANCE WITH GIV AMM
31-02-00 AVIONICS STANDARD COMMUNICATION BUS - FAULT ISOLATION WITH NO DISCREPANCIES.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
13.00
(0)
$132.00
$1.716.00
Total USD:
S 1.716.00
Step: 6.5.1
Completed
PERF'ORMED ASCB BUS SWEEP IAW GIVI=.
31-02-00. FOUND THAT
THERE WERE NUMEROUS BUS COUPLER CONNECTIONS THAT REQUIRED
CLEANING (NOTICED SIGNAL FLUCTUATION ON OSCILLOSCOPE).
CLEANED BUS COUPLER CONNECTIONS AS REQUIRED AND SECURED ALL
CONNECTIONS. CHECKED ASCB BUS CHANNELS A AND B, FOUND GOOD AT
THIS TIME.
Discrepancy: 6.6
WHILE PERFORMING SPZ-8000 GND MAINTENANCE TEST AFTER PERFORMING ASCB BUS SWEEP
FOUND FMS #1 WOULD NOT GO TO TEST MODE
Resolution: REMOVED NAV COMPUTER #1 PIN 7018879-03014 S/N 95120669. RECEIVED OK AND INSTALLED REPAIRED
NAV COMPUTER #1 P/N 7018879-03014 S/N 94100105 RECEIVED FROM HONEYWELL INTERNATIONAL INC
REFERENCE FAA FORM 8130-3 FORM TRACKING NUMBER 20160001363710Y15 323857863; WORK ORDER
321642311; APPROVAL CERT LV2R992K; DATED 16 FEB 2016. OPERATIONAL CHECK GOOD. WORK
PERFORMED IAW GULFSTREAM GIV CMP 349800 FLIGHT MANAGEMENT SYSTEM NO. 1 OPERATIONAL
CHECK AND GULFSTREAM GIV CMP 346015 FMS NAVIGATION COMPUTER NO. 1 REMOVAL/
INSTALLATION.
Billing Method
Hours
Rate
Total
Labor USD.
Time and Material
ST
4.02
C4
$132.00
S530.64
Total USD:
8530.64
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
6.682
7018879-03014
COMPUTER, NAVIGATION
1
$0.00
50,00
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 15 of 123
Printed: 3/21/2016 11:35:41AM
Rd: 322
EFTA00590810
Bill To: JEGE LLC
WO 9:
Invoice Number:
Discrepancy: 6.7
Resolution:
WHILE PERFORMING SPZ-8000 GND MAINTENANCE TEST NOTICED THAT THE LEFT FUEL LOW
LEVEL INDICATION STAYS WHITE IN ECIAS AND NO LIGHT ON STANDBY FUEL INDICATION WITH
ZERO FUEL ON WING.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
12.98
@
$132.00
$1,713.36
Parts USD:
Time and Material
$4,737.00
Total USD:
56,450.36
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
6.7 Al
1159SCF215-33
CONTROL UNIT, FUEL, LOW LEVEL
1
$4,737.00
$4,737.00
Step: 6.7.1
Step: 6.7.2
Step: 6.73
Completed
PERFORMED RESISTANCE CHECK OFTHE LEFT WING LOW LEVEL SENSOR
AND FOUND THAT IT WAS WITHIN LIMITS. WITH BOTH EICAS AND
STANDBY FUEL QUANTITY INDICATOR SHOWING NO LOW LEVEL
WARNING, WITH ZERO FUEL ON THE LEFT WING. AT CONNECTOR 15A1P1,
SWAPPED PINS C (CLOSE DRY LEFT SIGNAL) WITH PIN D (CLOSE DRY
RIGHT SIGNAL), AND THE PROBLEM FOLLOWED. SWAPPED BOTH PLNS
BACK TO THEIR ORIGINAL POSITIONS. CONFIRMED BAD FUEL LOW LEVEL
DUAL CONTROL UNIT. ALL WORK WAS DONE WITH REFERENCE TO GIV
28-07-00.
Completed
REMOVED FUEL QUANTITY DUAL LOW LEVEL CONTROL UNIT P/N:
1159SCF'215-33, S/N: 567 FROM THEAIRCRAFT. RECEIVED OK TO INSTALL
AND INSTALLED A REPAIRED FUEL QUANTITY DUAL LOW LEVEL CONTROL
UNIT P/N: 1159SCF215-33, S/N: 690 THAT WAS RECEIVED FROM PARKER
HANNIFIN CORP., ELECTRONICS SYSTEMS DIV. WITH FAA 8130-3 FORM
TRACKING NO.: 9E5210. APPROVAL/CERTIFICATE NO.: FX1R1561C. DATED
AUG/23/2010 TO THE AIRCRAFT. APPLIED POWER TO THE AIRCRAFT AND
FOUND THAT THE LEFT, RIGHT, AND TOTAL FUEL LEVEL INDICATION WAS
AMBER ON EICAS, ALSO THERE WAS LIGHT, (LEFT AND RIGHT) ON
STANDBY FUEL INDICATOR. WORK WAS DONE IAW GIV CMP 284020, FUEL
QUANTITY DUAL LOW LEVEL CONTROL UNIT - REMOVAL / INSTALLATION.
Open
NEED TO COMPLY WITH GIV CMP 284029. FUEL LOW LEVEL WARNING
SYSTEM - OPERATIONAL TEST.
Discrepancy: 6.8
DURING C/W CMP GIV 541019 PYLON INTERNAL (LEFT) - INSPECTION FOUND PRECOOLER INLET
TEMPERATURE SENSOR CANNON PLUG TO HAVE BROKEN WIRE
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
8.14
@
$132.00
$1,074.48
Total USD:
$1,074.48
Parts:
Rel. No.
Part number:
Description
Qu.intit)
:icll prikc USD
Extended USD
6.8 Al
NIS3106F12S-3S
CONNECTOR
1
$0.00
$0.00
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 16 of 123
Printed: 3/21/2016 II:35:41AM
Rd 322
EFTA00590811
Bill To: JEGE LLC
WO
Invoice Number:
Step: 6.8.1
Completed
REMOVED AND REPLACED CONNECTOR LEFT ENGINE PYLON TEMP
SENSOR P/N MS3106F12S-35 NEW FROM ELECTRO ENTERPRISES INC ..
WITH CERTIFICATE OF CONFORMANCE, PACK SLIP NO. 1781911 DATED
MAR 18.2016. WORK DONE IAW WESTERN COMMANDER , INC. WIRING
DIAGRAM NO. 08030131 - BLEED AIR CONTROL MONITOR. DATED 2/10189.
Step: 6.8.2
Open
NEED OPERATIONAL TEST
Discrepancy: 6.9
DURING AIRCRAFT POWER "ON", FOUND DC VOLTS ON ELECTRICAL POWER MONITOR TO READ
8.2 VOLTS WHEN SWITCH IS SET TO "AUX"
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
4.67
Cd
$132.00
$616.44
Total USD:
$616.44
Item: 7
INTERIOR
Team Manager.
Charles Heinig
Customer Coordinator:
Vinny Cicala
Part/Model 8:
AC Serial No./Tail No.:
TSNITSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 7.1
Resolution:
TO PROVIDE DOCUMENTATION OF REMOVED/REINSTALLED INTERIOR COMPONENTS ONLY.
Discrepancy: 7.2
Resolution:
CUSTOMER REPORTS THE COPILOTS AIR VENT IS INOP AND BROKEN.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
6.75
C4
$132.00
$891.00
Total USD:
$891.00
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
7.2 NI
2100136-1-10
TRANSDUCER, CABIN AIR
1
$0.00
S0.00
PRESSURE
7.2 82
P2333ES-QT
PAINT, GLOSS BLACK QUART
1
$0.00
S0.00
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GACJANkOrderPreliminaryInvoice.rm 2011
Page 17 of 123
Printed: 3/21/2016 II:35:41AM
Rd 322
EFTA00590812
Bill To: JEGE LLC
WO N:
Invoice Number:
Step: 7.2.1
Completed
FOUND AIRVENT BROKEN . ORDERED NEW AIR OUTLET P/N 1747-2 NSN.
RECIEVED AND INSTALLED NEW AIR OUTLET P/N 1747-2. REFERENCE PART
OR MATERIAL CERTIFICATION FORM REFERENCE/SO0 726461 DATED
3/14/2016
Step: 7.21
Open
COPILOTS AIR VENT REQUIRES OPS CHECK DURING A/C RUNS.
Discrepancy: 73
Resolution:
CUSTOMER REPORTS THE CAPTAIN'S AIR-VENT IS BROKEN.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
3.66
42)
$132.00
$483.12
Total USD:
$483.12
Step: 7.3.1
Step: 7.3.2
Completed
FOUND AIRVENT BROKEN . ORDERED NEW AIR OUTLET P/N 1747-2 NSN,
RECIEVED AND INSTALLED NEW AIR OUTLET P/N 1747-2. REFERENCE PART
OR MATERIAL CERTIFICATION FORM . REFERENCE/SOS 726461 DATED
3114/2016
Open
PILOTS AIR VENT REQUIRES OPS CHECK DURING A/C RUNS.
Discrepancy: 7A
Resolution:
Labor USD:
CUSTOMER REPORTS THE AIR VENT IN FWD LAV IS INOP.
Billing Method
Hours
Rate
Total
Time and Material
ST
5.28
@
$132.00
$696.96
Total USD:
$696.96
Discrepancy: 7.5
CUSTOMER REPORTS THE FWD LEFT SIDE WINDOW SHADE IS INOP (MOTOR CHANGE).
Resolution: GAINED ACCESS TO THE IJI1 #1 CABIN WINDOW SHADE BY REMOVING LAI #3 DADO PANEL, UN #2
CUPRAILSPEAKERS, LAI #1 DECO PANEL.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
10.65
42)
$132.00
$1,405.80
Services USD:
Time and Material
$1,776.25
Total USD:
$3,182.05
Services:
Ref. No.
Description
Quantity
Sell Price USD
Extended USD
75#1
GAC REPAIRS
1.00
$1,776.25
$1,776.25
Part Ref: LISA-005-013-19-P-ANN cabin window shade
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 18 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590813
Bill To: JEGE LLC
WO It:
Invoice Number.
Discrepancy: 7.6
CUSTOMER REPORTS THAT THE COPILOT'S WINDOW SHADE NEEDS NEW TINT INSTALLED.
GULFSTREAM PBI WARRANTY CONSIDERATION
Resolution:
Labor USD:
Billing Method
Hours
Rate
Total
Time and Material
ST
5.57
$132.00
$735.24
Total USD:
$735.24
Discrepancy: 7.7
CUSTOMER REQUEST TO CHECK ALL OVERHEAD LIGHTS AND GLARE SHIELD LIGHTS FOR
PROPER OPERATION (SOME AREAS ARE DARK, BY BOOST PUMPS, AND TRIM WHEEL).
Resolution: CUSTOMER ELECTS NO ACTION TAKEN AT THIS TIME
Discrepancy: 7.8
CUSTOMER REQUEST TO INSTALL NEW RUBBER SEALS DUE TO WATER LEAK IN REAR 5 GALLON
TANKS.
Resolution: VERIFIED WATER LEAKING FROM 81 AND 82 WATER TANK CAPS, REMOVED LEAKING SEALS FROM MI
AND 42 TANK CAPS AND INSTALLED NEW SEALS, P/N 36082. RECEIVED FROM DYNAMO AVIATION INC.
REFERENCE COC 8 16624 DATED FEB-18-2013. FILLED WATER TANKS AND FOUND NO LEAKS FROM CAP
SEALS. WORK PERFORMED IAW GIV GAC DWG SC42716008
REMOVED SIX LEAKING O-RINGS FROM THE QUICK DISCONNECTS ON THREE 5 GALLON WATER TANKS,
INSTALLED SIX NEW O-RINGS P/N 902-9-292 NSN. ON THE QUICK DISCONNECTS ON THREE 5 GALLON
WATER TANKS. PARTS RECEIVED FROM SELL GMBH REFERENCE EASA FORM 1 WITH TRACKING ft SP
2012 0080340818 AND W.O 80004151514 DATED 17 OCT 2012. LEAK CHECKED WITH NO DEFECTS NOTED.
WORK PERFORMED IAW GIV GAC DWG SC42716008.
Billing Method
Hours
Rate
Total
Parts USD:
Time and Material
$181.26
Total USD:
$181.26
Pans:
Rd. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
7.881
36082
ORING
2
$53.50
$107.00
7.882
902-9-292
ORING
6
$3.46
$20.76
7.883
36082
ORING
1
$53.50
$53.50
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoicc.rm 2011
Page 19 of 123
Printed: 321/2016 II:35:41AM
Rd: 322
EFTA00590814
Bill To: JEGE LLC
WO #:
Invoice Number.
Step: 7.8.1
Completed
VERIFIED WATER LEAKING FROM #1 AND #2 WATER TANK CAPS, REMOVED
LEAKING SEALS FROM #1 AND #2 TANK CAPS AND INSTALLED NEW SEALS,
P/N 36082. RECEIVED FROM DYNAMO AVIATION INC.
REFERENCE COC # 16624 DATED FEB-18-20B. FILLED WATER TANKS AND
FOUND NO LEAKS FROM CAP SEALS. WORK PERFORMED lAW GIV GAC
DWG SC42716008
Step: 7.8.2
Completed
REMOVED SIX LEAKING O-RINGS FROM THE QUICK DISCONNECTS ON
THREE 5 GALLON WATER TANKS, INSTALLED SIX NEW O-RINGS P/N
902-9-292 NSN. ON THE QUICK DISCONNECTS ON THREE 5 GALLON WATER
TANKS. LEAK CHECKED WITH NO DEFECTS NOTED. WORK PERFORMED
lAW GIV GAC DWG SC42716008.
Discrepancy: 7.9
UPON REMOVAL OF CARPET IN AFT LAVATORY FOUND CARPET WET, SOAKED WITH WHAT SEEMS
TO BE TOILET WATER.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
0.87
491
$132.00
$114.84
Services USD:
Time and Material
$62.50
Total USD:
$177.34
Services:
Ref. No.
Description
Quantity
Sell Price USD
Extended USD
7.9 Al
AIRCRAFT CLEANING
1.00
$6250
$62.50
Step: 7.9.1
Open
PERFORMED VISUAL INSPECTION OF AFT LAV TOILET A.SSY. NO EVIDENCE
OF BLUE STAINING ON UPPER PORTION OF TANK AROUND LINE
CONNECTIONS. DUMPED An' LAV TANK AND SERVICED WITH 5 GALLONS
OF WATER. FLUSHED TOILET A TOTAL OF TWELVE CYCLES WITH NO
LEAKS NOTED.
Step: 7.9.2
Open
REMOVED DRAIN TUBE FROM LAV AKSY AND COUPLER IN LAV SERVICE
PANEL
Item:
ADMINISTRATIVE USE ONLY, NO RETURN TO SERVICE REQUIRED
Team Manager.
Charles Helwig
Customer Coordinator:
Vinny Cicala
Pan/Model 4:
AC Serial No./Tail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 9.1
Resolution:
Services:
Ref. No.
SQUAWK ENTERED FOR ADMINISTRATIVE USE TO PROCESS PARTS FOR RETURN FOR CREDIT
ONLY
Description
Quantity
9.161
GAC REPAIRS
Part Ref: 822-0836-035 RTU-4200 (RADIO TUNING UNIT)
1.00
Item: 10
ADMINISTRATIVE USE FOR FUEL ONLY, NO RETURN TO SERVICE REQUIRED
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 20 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590815
Bill To: JEGE LLC
WO #:
Invoice Number.
Team Manager.
Charles llelwig
Customer Coordinator:
Vinny Cicala
Pan/Model $:
AC Serial No./Tail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 10.1
ADMINISTRATIVE USE ONLY TO FUEL AND DEFUEL AIRCRAFT AS REQUIRED
Resolution:
Item: II
NZ2010 V6.I FMS SYSTEM UPGRADE - TRIPLE
Team Manager.
Charles Helwig
Customer Coordinator:
Vinny Cicala
Pan/Model $:
AC Serial No./ ail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoicesm 20I I
Page 21 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590816
Bill To: JEGE LLC
WO N:
Discrepancy: 11.1
ASC 477A NZ2010 V6.1 FMS SYSTEM UPGRADE - TRIPLE
Invoice Number.
Resolution:
THIS AIRCRAFT SERVICE CHANGE UPGRADES THE EXISTING NZ-2000 FLIGHT MANAGEMENT
SYSTEMS (FMS), VIA INSTALLATION OF VERSION 6.1 SOFTWARE, TO AN NZ-2010 SYSTEM WITH
SBAS/LPV GPS UPGRADE
NEW COMPONENTS:
TWO (2) HONEYWELL WAAS CAPABLE GPS RECEIVERS (PART NUMBER (PN) HG2021KB01)
TWO (2) WAAS CAPABLE GPS ANTENNAS (PN 567-1575-137)
ONE (1) ASC 477 KIT, NZ-2000 FLIGHT MANAGEMENT SYSTEM (FMS) 6.1 UPGRADE.
MODIFIED COMPONENTS:
THREE (3) EACH HONEYWELL NZ-2000 NAVIGATION COMPUTERS (PN 7018879-030XX TO
7018879-03036)
TWO (2) EACH HONEYWELL PZ-800 PERFORMANCE COMPUTERS (PN 7004609-XXX TO 7004609-940)
PERFORMANCE COMPUTERS NOT AT A MINIMUM LEVEL OF PN 7004609-925 WILL REQUIRE
ADDITIONAL UPGRADES NOT COVERED BY THIS INSTALLATION. ADDITIONAL CHARGES WILL
APPLY.
PREREQUISITES:
NZ-2000 COMPUTERS: HARDWARE MOD "E". FOR UNITS WITHOUT THIS MODIFICATION,
HONEYWELL SERVICE BULLETIN 7018[SSN REDACTED] (PUB. NO. A21- 6111-004) WILL BE REQUIRED.
ESTIMATED ADDITIONAL COST IS $2,600/UNIT.
PZ-800 COMPUTERS: PART NUMBER 7004609-925. FOR UNITS NOT AT THE -925 LEVEL OR HIGHER,
ADDITIONAL MODIFICATIONS ARE REQUIRED AND WILL BE ADDRESSED ON A TIME AND
MATERIAL BASIS.
THE AIRCRAFT MUST CURRENTLY BE EQUIPPED WITH DUAL GLOBAL POSITIONING SYSTEM
(GPS) RECEIVERS.
AIRCRAFT SERIAL NUMBERS 1000 THROUGH 1389: GPS #1 AND #2 INSTALLATIONS NOT
INSTALLED BY GULFSTREAM STC ST01716AT-D WILL REQUIRE ENGINEERING REVIEW PRIOR TO
INCORPORATION OF THIS ASC
EXISTING FMS #1 AND #2 INSTALLATIONS MUST MATCH GULFSTREAM STC ST01715AT-D OR
EQUIVALENT PRIOR TO INCORPORATION.
CONCURRENT REQUIREMENTS: NONE
RE: PROPOSAL#
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
25.00
@
$132.00
$3,300.00
Parts USD:
Time and Material
$35.00
Services USD:
Time and Material
$2,640.00
Total USD:
$5,975.00
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
11.1#9
AIRCRAFT-HISTORY
FAA AIRCRAFT HISTORY RECORDS
1
$35.00
$35.00
Services:
Ref. No.
Description
Quantity
Sell Price USD
Extended USD
11.1 PI
GAC REPAIRS
1.00
$1,320.00
$1,320.00
11.1 #2
GAC REPAIRS
1.00
$1,320.00
$1,320.00
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 22 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590817
Bill To: JEGE LLC
WO I:
Invoice Number.
Item: 12
SYNTHETIC VISION (PDSV) - PROVISIONS
Team Manager.
Charles Hetwig
Customer Coordinator:
Vinny Cicala
Pan/Model 0:
AC Serial No/nil No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 12.1
SYNTHETIC VISION (PDSV) - PROVISIONS
Resolution:
PROVISION FOR SYNTHETIC VISION (PDSV) WILL BE INSTALLED.
NEW SVS SEL SWITCHES WILL BE INSTALLED ON THE PILOT AND CO-PILOT'S GLARESHIELD
AND PLACARDED INOP.
. : A NEW WIRING INTERFACE WILL BE INSTALLED BETWEEN THE EXISTING HONEYWELL
SYMBOL GENERATORS (SG'S), TRAFFIC ALERT AND COLLISION AVOIDANCE SYSTEM (TCAS),
GLOBAL POSITIONING SYSTEM (GPS) AND THE COCKPIT DISPLAY UNITS (DU'S).
PREREQUISITES:
ASC 476 - DU-88S INDICATING / RECORDING SYSTEMS (ATA 31) ELECTRONIC DISPLAY SYSTEM
DU-88S LIQUID CRYSTAL DISPLAY (LCD) INSTALLATION (PLANEDECK).
i ASC 477 - NZ 20106.1 SOFTWARE WITH SBAS/LPV GPS INSTALLATION.
CERTIFICATION: THIS INSTALLATION WILL BE ACCOMPLISHED UNDER A GULFSTREAM STC.
DEVIATIONS FROM THE STC (IF REQUIRED) WOULD BE COMPLETED ON A TIME AND MATERIAL
BASIS OR QUOTED SEPARATELY ON A WORK CHANGE REQUEST (WCR).
NOTES:
THESE ARE PROVISIONS ONLY. THE SYMBOL GENERATORS (SG'S) AND COCKPIT DISPLAY UNITS
(DU'S) WILL REQUIRE SOFTWARE UPGRADES AND MODIFICATIONS TO ACTIVATE THE SYNTHETIC
VISION (PDSV) CAPABILITY. ADDITIONAL CHARGES WILL APPLY.
SYNTHETIC VISION ACTIVATION IS PREDICATED ON COMPLETION OF THE GULFSTREAM STC.
PLEASE CONTACT YOUR GULFSTREAM REGIONAL SALES MANAGER (RSM) FOR CURRENT STC
STATUS.
THE COST OF TI I IS ITEM WILL BE DEDUCTED FROM THE FINAL PDSV INSTALLATION PRICE
WHEN TIIE CUSTOMERS ELECT TO COMPLETE THE INSTALLATION.
RE: PROPOSAL#
)-12
Billing Method
Hours
Rate
Total
Parts USD:
Time and Material
$1,949.94
Total USD:
$1,949.94
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
12,1 II
25-0929-2094
LENS
1
826994
$269.94
12,112
LED-42-15-BB-El tiGU
ANNC SWITCH, SVS SEL
2
$840.00
$1,680.00
Item: 13
ASC476B V1.10 SOFTWARE ENHANCEMENTS
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 23 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590818
Bill To: JEGE LLC
WO N:
Invoice Number.
Team Manager.
Charles lielwig
Customer Coordinator:
Vinny Cicala
Part/Model
AC Serial No./ ail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 13.1
ASC 476B V1.10 SOFTWARE ENHANCEMENTS
COMPLY WITH THE REVISION B OF ASC 476, INSTALLATION OF BARCO SERVICE BULLETIN
SBAV606167B.
WARRANTY: THE DISPLAY UNIT RETROFIT UPGRADE TO SOFTWARE VERSION, V1.10 WILL BE
PROVIDED AT NO CHARGE (NC) IF PERFORMED AT A GULFSTREAM GIV AUTHORIZED WARRANTY
FACILITY OR FACTORY AUTHORIZED SERVICE CENTER WITHIN TWENTY-FOUR (24) MONTHS OF
THE RELEASE DATE (08 AUGUST 2014) OF THIS REVISION.
PREREQUISITES: ASC 476 OR ASC 476A INDICATING / RECORDING SYSTEMS (ATA 31), ELECTRONIC
DISPLAY SYSTEM - DU-885 LIQUID CRYSTAL DISPLAY (LCD) INSTALLATION (PLANEDECK) AND
HAVING DISPLAY UNITS, PN K9321061A02 (BLACK) OR PART NUMBER 9321061A11 (GREY).
NOTES:
THIS ASC IS MANAGED BY PRODUCT SUPPORT PROGRAM MANAGEMENT (PSPM) AND MAY
ONLY BE INSTALLED AT GULFSTREAM AEROSPACE OR GULFSTREAM-APPROVED FACILITIES.
INCORPORATION MUST BE COORDINATED THROUGH GULFSTREAM SCHEDULING AT 800-
810-GULF (4853) OR
IF NOT SCHEDULED, AIRCRAFT DOWNTIME COULD INCREASE
SIGNIFICANTLY.
I ONLY QUALIFIED PERSONNEL SPECIFICALLY TRAINED AND EQUIPPED MAY ACCOMPLISH THE
BARCO SERVICE BULLETIN, SBAV606167B REV 00 (OR LATER REVISION).
RE: PROPOSALN
)-13
•+s WARRANTY - NO CHARGE ASC ***
Resolution: FOUND ASC 476E V1.10 SOFTWARE ENHANCEMENTS PART 1 DATED 8 AUG 2014 TO BE PREVIOUSLY
COMPLIED WITH BY GAC - PBI. REFERENCE GAC - PBI WON SCI6531 AND AIRFRAME LOG BOOK ENTRY
DATED 12(18/2014, ACTT 8867.7, ACTL 4094. UPDATED GIV CMP 974762 ASC 476B V1.10 SOFTWARE
ENHANCEMENTS PART 1.
FOUND ASC 476E V1.10 SOFTWARE ENHANCEMENTS PART 2 DATED 8 AUG 2014 TO BE NOT APPLICABLE
DUE TO OPTIONAL XM WEATHER IS INSTALLED. UPDATED GIV CAP 974763 ASC 476B VI.10 SOFTWARE
ENHANCEMENTS PART 2.
VERIFIED INSERTION OF AFM SUPPLEMENT NO. GIV-2011-01, REV. "D" DATED 13 APR 2015 INTO
APPROVED Aft SUPPLEMENTS BOOK.
Item: 14
ASC 4158 INDICATING AND RECORDING - UPGRADE SPZ-8000/8400
Team Manager.
Charles Helwig
Customer Coordinator:
Vinny Cicala
Part/Model
AC Serial No./ ail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 24 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590819
Bill To: JEGE LLC
WO it:
Discrepancy: 141
ASC 415B INDICATING AND RECORDING - UPGRADE SPZ-8000/8400
Invoice Number.
THIS SERVICE CHANGE REVISION UPGRADES THE FAULT WARNING COMPUTERS (FWC) AND, IN
SOME CASES, THE SYMBOL GENERATORS (SG). FOR A DETAILED DESCRIPTION OF THE
IMPROVEMENTS OFFERED WITH THIS UPGRADE, PLEASE LOG IN TO YOUR
PORTAL AND REVIEW THE "SPZ-8000 MODIFICATION SUMMARY" LISTED
ON PAGE 8 OF ASC 4158.
PREREQUISITES: NONE
EFFECTIVITY: THIS SERVICE CHANGE IS EFFECTIVE FOR GIV AIRCRAFT 1000-1472. THIS OR A
SIMILAR CHANGE WILL BE INSTALLED INPRODUCTION ON AIRCRAFT 1473 AND SUBSEQUENT.
NOTE: THIS PROPOSAL DOES NOT INCLUDE ANY SQUAWKS, PRE-EXISTING DLSCREPANCIES OR
VENDOR SERVICE BULLETINS THAT MAY BE REQUIRED, EXCEPT AS SPECIFIED. IF REQUIRED,
THIS ADDITIONAL WORK WILL BE HANDLED ON THE BASLS OF TIME AND MATERIALS.
RE: PROPOSAL#
1-1A
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 14.2
REFURB AVIONICS SUPPORT FOR ASC 415B INDICATING AND RECORDING - UPGRADE SPZ-800W8400
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 143
CMP GIV 974154 ASC4I5B HONEYWELL SYSTEM UPGRA
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 14.4
CMPGIV 314005 Fault Warning Computer No. 1 - Removal / Installation
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 14.5
CMPGIV 314006 Fault Warning Computer No. 2 - Removal / Installation
Resolution: CUSTOMER ELECTS NO ACTION
For detail description or the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 25 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590820
Bill To: JEGE LLC
WO tl:
Invoice Number.
Discrepancy: 14.6
CMP GIV 316011 Symbol Generator No. 1 - Removal / Installation
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 14.7
CMP GIV 316012 Symbol Generator No. 2 - Removal / Installation
Resolution: CUSTOMER ELECTS NO ACTION
Discrepancy: 14.8
CMP GIN, 316013 Symbol Generator No. 3 - Removal / Installation
Resolution: CUSTOMER ELECTS NO ACTION
Item: 15
12 MONTH CAP TASKS (GIV SN 1085)
Team Manager.
Charles Helwig
Customer Coordinator:
Vinny Cicala
Pa/Model Sr:
AC Serial No./Tail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: BA
12 MONTH CAP TASKS (LABOR ONLY)
Resolution:
ACCOMPLISH 12 MONTH CMP TASKS. (EXHIBIT 1)
NOTES:
CORRECTION OF DISCREPANCIES IS NOT INCLUDED IN THE QUOTED PRICE.
7 DUE LIST PROJECTED THROUGH 31 DECEMBER 2016.
RE: PROPOSAL
2.1
•** LABOR ONLY
Billing Method
Hours
Rate
Total
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 26 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 331
EFTA00590821
Bill To: JEGE LLC
Labor USD:
Flat Rate
Total USD:
WO 9:
Invoice Number:
41,943.55
$1,943.55
Discrepancy: 15/
ACCOMPLISH THE 12 MONTH SERVICE CMP TASKS BELOW:
Resolution:
Billing Method
Hours
Rate
Total
Parts USD:
Total USD:
Parts:
Ref. No.
Time and Material
Part number:
Description
$79.93
Extended USD
Quantity
$79.93
Sell price USD
15.2 MI
515X333-2OZ
2 OZ TOUCHUP KIT, GREEN EPDXY
1
$18.64
$18.64
PRIMER
15.212
PR1448BI.2DAB-KIT
SEALANT, 50 GRAM KIT (CUP &
1
$25A9
$25.49
SYRINGE) (MEETS SPEC
AMS-S-8802 REV C) (INTERNAL
ONLY)
15.2 #3
MS24665-151
COTTER PIN
5
$0.75
$3.90
15.2 #4
M524665-153
PIN, COTTER
5
$0.75
$3.90
15.2 #5
MS21256-1
CLIP
S
$0.75
$6.24
15.2#7
515X333-2OZ
2 OZ TOUCHUP KIT, GREEN EPDXY
1
515.64
$18.µ
PRIMER
15.2 /48
NIS24694C58
SCREW
4
$0.75
$3.12
Discrepancy: 153
CMP GIV 256269 LIFE VESTS--INTEG. CHECK
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.4
CMP GIV 262582 EXT, 1120 AFT CABIN--INSPECT
Resolution: COMPLIED WITH CAW GIV 262582 EXT, H20 AFT CABIN—INSPECT
Discrepancy: 15.5
CMP GIV 262621 Port Halon Fire Extn (Right Cockpit) - Weight Check
Resolution: COMPLIED WITH CMP GIV 262621 Port Raton Fire Extn (Right Cockpit) - Weight Check
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOnierPreliminaryInvoice.rpt 2011
Page 27 of 123
Printed: 3/21/2016 11:35:41 AM
Ret:312
EFTA00590822
Bill To: JEGE LLC
WO 9:
Invoice Number.
Discrepancy: 15.6
CMP GIV 262601 EXTINGUISHER, HALON COCKPIT
Resolution: COMPLIED WITH CMP GIV 262601 EXTINGUISHER, HALON COCKPIT
Discrepancy: 15.7
CMP GIV 262622 Port Ilalon Fire Extn (Fwd Cabin) - Weight Check
Resolution: COMPLIED WITH CMP GIV 262622 Port !talon Fire Extn (Fwd Cabin) - Weight Check
Discrepancy: 15.8
CMP GIV 262612 Portable Halon Fire Extinguisher (Forward Cabin) - Hydrostatic Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.9
CMP GIV 262623 Port Halon Fire Extn (Aft Cabin) - Weight Check
Resolution: COMPLIED WITH CMP GIV 262623 Port Halon Fire Extn (Aft Cabin) - Weight Check
Discrepancy: 15.10
CMP GIV 262603 EXTINGUISHER, HALON AFT CABIN
Resolution: COMPLIED WITH CMP GIV 262603 EXTINGUISHER, HALON AFT CABIN
Discrepancy: 15.11
CMP GIV 262633 Port Halon Fire Extn (Aft Cabin) - Inspection
Resolution: COMPLIED WITH CMP GIV 262633 Port !talon Fire Extn (Aft Cabin) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 28 of 123
Printed: 321/2016 11:35:41 AM
■e 322
EFTA00590823
Bill To: JEGE LLC
WO 4:
Invoice Number.
Discrepancy: 15.12
CMPGIV 270011 Control Surface Hinge Joints - Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.13
CMPGIV 271029 Aileron Actuator Load Relief Bungee (Left) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TINIE.
Discrepancy: 15.14
CMPGIV 271039 Aileron Actuator Load Relief Bungee (Right) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.15
CMPGIV 273056 Elevator Actuator Load Relief Bungee - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.16
CMPGIV 322042 Nose Gear Axle Assembly - Corrosion Prevention
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.17
CMPGIV 320027 Nose Landing Gear Axle Assembly - Corrosion Inhibiting Compound Application
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 29 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590824
Bill To: JEGE LLC
WO ft:
Invoice Number.
Discrepancy: 15.18
CMPGIV 322035 Nose Gear Axle Fitting - Reims al / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.19
CMPGIV 324009 WHEEL, LEFT NOSE GEAR
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.20
CMPGIV 324010 WHEEL, RIGHT NOSE GEAR
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.21
CMPGIV 324038 TIRE - SERVICING
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.22
CMPGIV 324049 Nose Gear Wheel Bearings (Left) - Inspection / Pack
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.23
CMPGIV 324050 Nose Gear Wheel Bearings (Right) - Inspection / Pack
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 30 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590825
Bill To: JEGE LLC
W()
Invoice Number.
Discrepancy: 15.24
CMPGIV 351005 Crew Oxygen System (Pilot) - Operational Test
Resolution:
Discrepancy: 15.25
CMPGIV 351006 Crew Oxygen System (Co-Pilot) - Operational Test
Resolution:
Discrepancy: 15.26
CMPGIV 351007 Crew Oxygen System (Jumpseat) - Operational Test
Resolution:
Discrepancy: 15.27
CMPGIV 521003 Main Entrance Door - Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.28
CMPGIV 521008 Main Entrance Inflatable Seal System - Operational Test
Resolution: COMPLIED WITH CMP DIV 521008 Main Entrance Inflatable Seal System - Operational Test
Discrepancy: 15.29
CMPGIV 521009 Baggage Door Inflatable Seal Sys - Ops Test
Resolution: COMPLIED WITH CMP GI V 521009 Baggage Door Inflatable Seal Sys - Ops Test
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 31 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590826
Bill To: JEGE LLC
WO
Invoice Number.
Discrepancy: 15.30
CMPGIV 521080 Inflatable Door Seal - Purging Procedure
Resolution: COMPLIED WITH CMP GIV 521080 Inflatable Door Seal - Purging Procedure
Discrepancy: 15.31
CMP GIV 523004 Baggage Door -Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.32
CMPGIV 534015 Main Landing Gear Installation (Left) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.33
CMPGIV 534016 Main Landing Gear Installation (Right) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.34
CMPGIV 534018 Blain Landing Gear Wheel Well Compartment - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.35
CMPGIV 534020 Nose Wheel Well and Gear - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_Work0rderPreliminaryInvoice.rm 2011
Page 32 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590827
Bill To: JEGE LLC
WO ft:
Invoice Number.
Discrepancy: 15.36
CMPGIV 571030 Wing Vertical Breather Angle -Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.37
CMP GIV 710019 Powerplant - Internal Inspection
Resolution: COMPLIED WITH CMP GIV 71111119 Pun erplant - Internal Inspection
Discrepancy: 15.38
CMPGIV 711009 Cowl Latch, Engine (Left) - Rigging
Resolution: COMPLIED WITH CMP GIV 711009 Cowl Latch, Engine (Left) - Rigging
Discrepancy: 1539
CMPGIV 710020 Powerplant - Internal Inspection
Resolution: COMPLIED WITH CMP GIV 710020 Powerplant - Internal Inspection
Discrepancy: 15.40
CMPGIV 711010 Cowl Latch, Engine (Right) - Rigging
Resolution: COMPLIED WITH CMP GIV 711010 COWL LATCH, ENGINE (RIGHT) - RIGGING
Discrepancy: 15.41
ACCOMPLISH THE 12 MONTH AVIONICS CMPTASKS BELOW:
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 33 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590828
Bill To: JEGE LLC
WO
Invoice Number.
Discrepancy: 15.42
CMPGIV 237004 Cockpit Voice Recorder System - Operational Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.43
CRIP GIV 240250 Emergency Securaplane Battery No. 1 - Bullt-In Test Equipment / Battery Level Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.44
CMPGIV 240251 Emergency Securaplane Battery No. 2 - Built-in Test Equipment / Battery Level Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.45
CMPGIV 240252 Emergency Securaplane Battery No. 3 - Built-in Test Equipment / Battery Level Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.46
CMPGIV 240253 Emergency Securaplane Battery No. 4 - Built-in Test Equipment/ Battery Level Test
Resolution: CUSTOMER ELECTS NO ACTION AT THIS TIME.
Discrepancy: 15.47
CMPGIV 250001* ICA FOR LCD MONITOR
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 34 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590829
Bill To: JEGE LLC
WO tl:
Invoice Number.
Discrepancy: 15.48
CMPGIV 250002* ICA FOR 406MHZ ELT
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.49
CMPGIV 256110 Emergency Locator Transmitter- Operational Test (FAR 91.207)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.50
CMPGIV 256105 Emergency Locator Transmitter - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.51
CMPGIV 312015 BATTERY, PILOT CLOCK
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.52
CMPGIV 312016 BATTERY, COPILOT CLOCK
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.53
CMPGIV 330007 Emergency Exit Lights - Operational Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description or the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 35 of 123
Printed: 321/2016 11:35:41AM
Rea
EFTA00590830
Bill To: JEGE LLC
WO $1:
Invoice Number.
Discrepancy: 15.54
CMPGIV 330010 Exterior Lights - Operational Test
Resolution: COMPLIED WITH CMP GIV 330010 Exterior Lights - Operational Test
Discrepancy: 15.55
CMPGIV 344095 Inertial Reference Unit No. 1 Securaplane Battery (Built-In Test Equipment /Battery Level
Test) - Operational Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.56
CMPGIV 344096 Inertial Reference Unit No. 2 Securaplane Battery (Built-In Test Equipment / Battery Level
Test) - Operational Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 15.57
CMPGIV 344097 Inertial Reference Unit No. 3 Securaplane Battery (Built-In Test Equipment / Battery Level
Test) - Operational Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
item: 16
12 MONTH CMP TASKS DISCREPANCIES
Team Manager.
Charles Ilelwig
Customer Coordinator:
Vinny Cicala
Part/Model $:
AC Serial No./ ail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 16.1
WHILE C/W CMPGIV 330010 EXTERIOR LIGHTS - OPERATIONAL TEST FOUND TAIL CONE LOWER
LIGHT (BELOW STROBE) TO BE INOP, NOT ILLUMINATED.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 36 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 331
EFTA00590831
Bill To: JEGE LLC
WON:
Invoice Number.
Resolution: REMOVED TAIL CONE LOWER LIGHT BULB P/N 1683 NSN. RECEIVED OK TO INSTALL INSTALLED NEW
LIGHT BULB P/N 1683 NSN RECEIVED FROM CAC BAF STOCK. REFERENCE COMPONENT
886 FOR
OPS CHECK.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
4.02
(3)
$132.00
$530.64
Parts USD:
Time and Material
$34.62
Total USD:
$565.26
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
16.1 al
44GN11-3OZ
TOUCHUP KIT, DEFT EPDXY
1
$32.00
$32.00
PRIMER & CATALYST- ADD WATER
(INTERNAL USE ONLY)
16.1 12
1683
LAMP
1
$2.62
$2.62
Discrepancy: 16.2
WHILE C/W CMP GIV 330010 EXTERIOR LIGHTS - OPERATIONAL TEST FOUND L/H LOGO LIGHT TO
BE INOP, NOT ILLUMINATED.
Resolution: REMOVED LH LOGO LIGHT BULB P/N 4713 NSN. INSTALLED NEW LIGHT BULB P/N 4713 NSN. REFERENCE
CERTIFICATE OF CONFORMANCE FROM AVIALL PURCHASE ORDER: WEPO16-01287 DATED 16MAR16.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.64
(3)
$132.00
$348.48
Pans USD:
Time and Material
$150.26
Total USD:
$498.74
Parts:
Ref. No.
Part number
Description
Quantity
Sell price USD
Extended USD
16.2 MI
4713
LAMP
1
$150.26
$150.26
Item: 17
24 MONTH CMP TASKS (GIV SN 1085)
Team Manager.
Charles Ileiwig
Customer Coordinator:
Vinny Cicala
Pan/Model M:
AC Serial No./Thil No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 17.1
24 MONTH CAP TASKS (LABOR ONLY)
ACCOMPLISH 24 MONTH CMP TASKS (EXHIBIT 2)
NOTES:
CORRECTION OF DISCREPANCIES IS NOT INCLUDED IN THE QUOTED PRICE.
DUE LIST PROJECTED THROUGH 31 DECEMBER 2016.
RE: PROPOSAL
-2.2
it* LABOR ONLY
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 37 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590832
Bill To: JEGE LLC
Resolution:
WO e:
Invoice Number.
Billing Method
Hours
Rate
Total
Labor USD:
Flat Rate
$27,765.00
Total USD:
$27,765.00
Discrepancy: 17.2
ACCOMPLISH THE 24 MONTH SERVICE CAW TASKS BELOW:
Resolution:
Billing Method
Hours
Rate
Total
Parts USD:
Total USD:
Parts:
Ref. No.
Time and Material
Part number:
Description
$1,852.17
Extended USD
Quantity
$1,852.17
Sell price USD
17.211
MS27039-0806
SCREW
2
$0.78
$1.56
17.212
159BNI10108-1
PIN (STA 138-164 DOOR HINGE)
2
$53.50
$107.00
17.213
MS29512-06
O-RING, TUBE FITTING PACKING
1
50.78
$0.78
17.214
14528778-6
PACKING, PREFORMED TUBE
1
$2.06
$2.06
FITTING
17.215
14528775-110
SEAL
1
$3.21
$3.21
17.216
139419-1
FILTER
1
$59A3
$59.43
17.217
139495-1
FILTER
1
$759.11
$759.11
17.218
S2L-226
O-RING SEAL. FLUOROCARBON
4
$8.49
$33.96
(VITON) LOW COMPRESSION. 2.00
IN.
17.219
521.230
O-RING SEAL. FLUOROCARBON
8
$5.00
$40.00
(VITON) LOW COMPRESSION. 2.50
IN.
17.2110
NASI580C3T4
BOLT
25
$0.78
$19.50
17.2112
NIS24665-153
PIN, COTTER
9
$0.78
$7.02
17.2113
MS24665-15I
COTTER PIN
9
$0.78
$7.02
17.2114
NIS21256-1
CLIP
ID
$0.78
$7.80
17.2115
NAS335CPA7
BOLT
I8
$0.78
$14.04
17.2116
MS24665-153
PIN, COTTER
4
$0.78
$3.12
17.2117
NASI612-12A
O-RING, TUBING
2
$0.92
$1.84
17.2118
89026E112
O'RING
2
$0.78
$1.56
17.2120
M83248-I-905
O'RING
2
$0.78
$1.56
17.2121
GAS570G8A
SEAL. FLUID/AIR-M533649 PORT
2
$390.02
$780.04
17.2123
NIS24665-22
COTTER PIN
2
$0.78
$1.56
Discrepancy: 17.3
CNIP GIV 212077 Air Conditioning Shutoff Valve Filter (Left) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WarkOrderPreliminaryInvoice.rpt 2011
Page 38 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590833
Bill To: JEGE LLC
WO #:
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Invoice Number.
Discrepancy: 17.4
CMPGIV 212061 Air Conditioning Shut-off Valve Filter (Left) - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.5
CMPGIV 212078 Air Conditioning Shutoff Valve Filter (Right) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.6
CMPGIV 212062 Air Conditioning Shut-off Valve Filter (Right) - Removal / Installation
Resolution:
Discrepancy: 17.7
CMPGIV 212115 Nose Compartment Cooling Sys - Operational Test
Resolution: COMPLIED WITH CMP CIV 212115 Nose Compartment Cooling Sys - Operational Test
Discrepancy: 17.8
CMPGIV 213053 Cabin Pressure Warning Indication Sys - Functional Test
Resolution:
Discrepancy: 17.9
CMPGIV 213081 Pressuriiniiint Safet Vats e - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 39 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 322
EFTA00590834
Bill To: JEGE LLC
Resolution:
WO tr
Invoice Number.
Discrepancy: 17.10
CMPGIV 213083 Pressurization Safety Valve - Ground Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.11
CMPGIV 213052 Cabin Pressure Warning (Aneroid) Switch (4751) - Removal / Installation
Resolution:
Discrepancy: 17.12
CMPGIV 213090 Cabin Pressure Control (Manual Mode) Ops Test
Resolution:
Discrepancy: 17.13
CMPGIV 216097 Air Cycle Machine Compressor Outlet Overheat Switch (Left) - nip Point Check
Resolution: COMPLIED WITH CMP GIV 216097 Air Cycle Machine Compressor Outlet Overheat Switch (Left) - Trip Point Check
Discrepancy: 17.14
CMPGIV 216095 Air Cycle Machine Compressor Outlet Overheat Switch (Left) - Removal / Installation
Resolution: COMPLIED WITH CMP G1V 216095 Air Cycle Machine Compressor Outlet Overheat Switch (Left) - Removal /
Installation
Discrepancy: 17.15
CMPGIV 216098 Air Cycle Machine Compressor Outlet Overheat Switch (Right) -Trip Point Check
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 40 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590835
Bill To: JEGE LLC
WO
Invoice Number:
Resolution: COMPLIED WITH CMP GIV 216098 Air Cycle Machine Compressor Outlet Overheat Switch (Right) - Trip Point
Check
Discrepancy: 17.16
CMP GIV 216096 SW, R ACNI Compress Out O/11eat
Resolution: REMOVED OUTLET OVERHEAT SWITCH WITH P/N 1173T0458, S/N 1914. INSTALLED A NEW OUTLET
OVERHEAT SWITCH WITH P/N 1173T0458 S/N 2086. REFERENCE 8130-3 WITH FORM TRACKING #
20141124015239 DATED 24 NOV 2014 FROM GULFSTREANI AEROSPACE CORP. CRS# ODA-511131 . ALL
WORK DONE IN ACCORDANCE WITH GV AMA 21-01-09 AND CMP GIV 216096 SW, R ACM COMPRESS OUT
O/HEAT OP CHECKS GOOD
UPDATE CMP AS REQUIRED
Discrepancy: 17.17
CMP GIV 243030 Auxiliary TRU - Inspection / Cleaning
Resolution: COMPLIED WITH CMP GIV 243030 Auxiliary TRU - Inspection / Cleaning
Discrepancy: 17.18
CMP GIV 243025 Auxiliary Transformer-Rectifier Unit - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 243025 Auxiliary Transformer-Rectifier Unit - Removal / Installation
Discrepancy: 17.19
CAP GIV 251125 Pilot / Copilot Inertia Reel - Operational Test
Resolution: COMPLIED WITH CMP GIV 251125 Pilot / Copilot Inertia Reel - Operational Test
Discrepancy: 17.20
CMP GIV 261035 Eng Alternator Overheat Switch (Left) - Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261035 Eng Alternator Overheat Switch (Left) - Trip Point Check
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 41 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590836
Bill To: JEGE LLC
WO #:
Invoice Number.
Discrepancy: 17.21
CMPGIV 261025 SWITCH, L ENG ALT O/H
Resolution: COMPLIED WITH CMP GIV 261025 SWITCH, L ENG ALT O/H
Discrepancy: 17.22
CMP GIV 261036 Eng Alternator Overheat Switch (Right) - Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261036 Eng Alternator Overheat Switch (Right) - Trip Point Check
Discrepancy: 17.23
CMPGIV 261030 SWITCH, R ENG ALT O/H
Resolution: COMPLIED WITH CMP GIV 261030 SWITCH, R ENG ALT O/H
Discrepancy: 17.24
CMPGIV 261065 Combined Hyd Sys Overheat Switch - Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261065 Combined Ilyd Sys Overheat Switch - Trip Point Check
Discrepancy: 17.25
CMPGIV 261055 Combined Hydraulic System Overheat Switch - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 261055 Combined Hydraulic System Overheat Switch - Removal / Installation
Discrepancy: 17.26
CMPGIV 291057 Combined / Flight Hydraulic System Reservoir - Filling Procedures
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 42 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590837
Bill To: JEGE LLC
WO 41:
Invoice Number.
Discrepancy: 17.27
CMPGIV 261066 Flight Hyd Sys Overheat Switch -Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261066 Flight Hyd Sys Overheat Switch - hip Point Check
Discrepancy: 17.28
CMPGIV 261060 Flight Hydraulic System Overheat Switch - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 261060 Flight Hydraulic System Overheat Switch - Removal / Installation
Discrepancy: 17.29
CMPGIV 261235 Bleed Alr Manifold OfH Switch (Left) - 'nip Point Check
Resolution: COMPLIED WITH CMP GIV 261235 Bleed Air Manifold OfH Switch (Left) - Trip Point Check
Discrepancy: 17.30
CMPGIV 261225 SWITCH, L BLEED AIR OfH
Resolution: COMPLIED WITH OAP GIV 261225 SWITCH, L BLEED AIR OfH
Discrepancy: 1731
CMPGIV 261236 Bleed Alr Manifold OfH Switch (Right) -Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261236 Bleed Air Manifold Offl Switch (Right) - nip Point Check
Discrepancy: 1732
CMPGIV 261230 SWITCH, R BLEED AIR Offl
Resolution: COMPLIED WITH CMP GIV 261230 SWITCH, R BLEED AIR Offl
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 43 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590838
Bill To: JEGE LLC
WO #:
Invoice Number.
Discrepancy: 1733
CMP GIV 261440 APU Overheat Switch -Trip Point Check
Resolution: COMPLIED WITH CMP GIV 261440 APU Overheat Switch - Trip Point Check
Discrepancy: 1734
CMP GIV 261415 SWITCH, TOP APU FIRE DET
Resolution: COMPLIED WITH CMP GIV 261415 SWITCH, TOP APU FIRE DET REMOVAL AND INSTALLATION
Discrepancy: 1735
CMP GIV 261420 SWITCH, BOT APU FIRE DET
Resolution: COMPLIED WITH CMP GIV 261420 SWITCH, BOT APU FIRE DET REMOVAL AND INSTALLATION
Discrepancy: 17.36
CMP GIV 261425 SWITCH, ABOVE ALT APU F/DET
Resolution: COMPLIED WITH CMP GIV 261425 SWITCH, ABOVE ALT APU F/DET REMOVAL AND INSTALLATION
Discrepancy: 1737
CMP GIV 261430 SWITCH, API) AIR INLET FIRE DET
Resolution: COMPLIED WITH CMP GIV 261430 SWITCH, APU AIR INLET FIRE DET REMOVAL AND INSTALLATION
Discrepancy: 17.38
CMP GIV 262075 Fire Bottle (APU) - Weight Check
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 44 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590839
Bill To: JEGE LLC
WO 9:
Invoice Number.
Discrepancy: 17.39
CMPGIV 262035 Bottle, Engine Fire (APU)
Resolution: CUSTOMER PCW. CUSTOMER ELECTS NO ACTION.
Discrepancy: 17.40
CMPGIV 262155 Fire Pull Handle - Operational Test
Resolution: COMPLIED WITH CMP GIV 262155 Fire Pull Handle - Operational Test
Discrepancy: 17.41
CMPGIV 262165 Fire Extinguisher System (Left) - Functional Test
Resolution: COMPLIED WITH CMP GIV 262165 Fire Extinguisher System (Left) - Functional Test
Discrepancy: 17.42
CMPGIV 262166 Fire Extinguisher System (Right) - Functional Test
Resolution: COMPLIED WITH CMP GIV 262166 Fire Extinguisher System (Right) - Functional Test
Discrepancy: 17.43
CMPGIV 262170 Fire Extinguisher System (APU) - Functional Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.44
CMPGIV 270006 Shut-off Valve, Flight Control Manual - Operational Test
Resolution: COMPLIED WITH CMP GIV 270006 Shut-off Valve, Flight Control Manual - Operational Test
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 45 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590840
Bill To: JEGE LLC
WO tr
Invoice Number.
Discrepancy: 17.45
OAP GIV 276001 Ground Spoiler System - Operational Test
Resolution:
Discrepancy: 17.46
CHF GIV 276004 Ground Spoiler Fault Detection Sys - Functional Test
Resolution:
Discrepancy: 17.47
ChIP GIV 282073 APO Wing Fuel Shut-Off Valve - Functional Test
Resolution:
Discrepancy: 17.48
CHF GIV 301005 Wing Anti-Ice (Lea) - Operational Test
Resolution:
Discrepancy: 17.49
CNIP GIV 301006 Wing Anti-Ice (Right) - Operational Test
Resolution:
Discrepancy: 17.50
OAP GIV 302005 Cowl Anti-Ice (Left Engine) - Operational Test
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_VMrkOrderPreliminarylnvoice.rm 2011
Page 46 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590841
Bill To: JEGE LLC
WO
Invoice Number.
Discrepancy: 17.51
CMP GIV 302006 Cowl Anti-Ice (Right Engine) - Operational Test
Resolution:
Discrepancy: 17.52
CMP GIV 303009 Total Temp Probe Heat System - Operational Test
Resolution: COMPLIED WITH CMP GIV 303009 Total Temp Probe Heat System - Operational Test
Discrepancy: 17.53
CMP GIV 303012 Angle of Attack Heat - Operational Test
Resolution: COMPLIED WITH CMP GIV 303012 Angle of Attack Heat - Operational Test
Discrepancy: 17.54
CMP GIV 320009 Landing Gear (Left Main) Corrosion Inhibiting Compound Re-Application
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.55
CMP GIV 320010 Landing Gear (Right Main) Corrosion Inhibiting Compound Re-Application
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.56
CMP GIV 320034 Landing Gear (Nose) Corrosion Inhibiting Compound Re-Application
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 47 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590842
Bill To: JEGE LLC
WO ft:
Invoice Number.
Discrepancy: 17.57
CMPGIV 321041 Main Gear Shock Absorber (Lett) - Service
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.58
CMPGIV 321042 Main Gear Shock Absorber (Right) - Service
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.59
CMPGIV 322006 Nose Gear Shock Strut - Friction Check
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.60
CMPGIV 322028 Nose Gear Shock Strut - Service
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.61
CMPGIV 322433 Nose Landing Gear Spring Rod Assembly - Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.62
CMPGIV 322430 Nose Landing Gear Spring Rod Assembly - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 48 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590843
Bill To: JEGE LLC
WO 0:
Invoice Number.
Discrepancy: 17.63
CMP GIV 323002 L(G CYCLING OPERATIONAL TEST
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.64
CMP GIV 323003 N/G SEQUENCING LINKAGE-CK/ADJ
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.65
CMPGIV 322434 Main Landing Gear Bungee (Left) - Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.66
CMPGIV 322431 Main Landing Gear Bungee (Left) - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.67
CMPGIV 322435 Main Landing Gear Bungee (Right) - Lubrication
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.68
CMPGIV 322432 Main Landing Gear Bungee (Right) - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 49 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590844
Bill To: JEGE LLC
WO ft:
Invoice Number.
Discrepancy: 17.69
CMP GIV 323001 Landing Gear - Normal - Functional Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.70
CMP GIV 323004 Landing Gear - Emergency - Functional Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.71
CMP GIV 323101 Emergency Landing Gear System - Flush
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.72
CMP GIV 323115 BOTTLE, LG AIR--SERVICE
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.73
CMP GIV 323025 Slain Gear Side Brace Fitting Pin (Left) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.74
CMP GIV 323015 Actuator, Side Brace (Left)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 50 of 123
Printed: 321/2016 11:35:41 AM
■e 322
EFTA00590845
Bill To: JEGE LLC
WO ft:
Invoice Number.
Discrepancy: 17.75
CMP GIV 323026 Main Gear Side Brace Fitting Pin (Right) - Inspection
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.76
Chflo GIV 323016 Actuator, Side Brace (Right)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.77
CMP GIV 324101 Wheel Brake - Functional Test (Brake-By-Wire)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.78
CMP GIV 341052 TAT Probe Aspirator - Operational Test
Resolution:
Discrepancy: 17.79
CMP GIV 352005 Passenger Oxygen System - Operational Test
Resolution:
Discrepancy: 17.80
CMP GIV 362005 Bleed Air Manifold Pressure Indication - Functional Test
Resolution: COMPLIED WITH CMP GIV 362005 Bleed Air Manifold Pressure Indication - Functional Test
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 51 of 123
Printed: 321/2016 11:35:41 AM
■e 322
EFTA00590846
Bill To: JEGE LLC
WO It:
Invoice Number.
Discrepancy: 17.81
CMPGIV 510070 24 Month Honeycomb (Aluminum) - Inspection / Bond Test
Resolution: COMPLIED WITH CMP MY 510070 24 Month Honeycomb (Aluminum) - Inspection / Bond Test
Discrepancy: 17.82
CMPGIV 521007 Main Entrance Door - Inspection
Resolution: COMPLIED WITH CMP GIV 521007 MAIN ENTRANCE DOOR - INSPECTION WITH SATISFACTORY RESULTS.
ACCOMPLISHED FOLLOW ON CMP GIV 521002 MAIN ENTRANCE DOOR CABLES - TENSION CHECK WITH
SATISFACTORY RESULTS.
Discrepancy: 17.83
CMPGIV 521002 MAIN ENT DR CABLE TENSION CK
Resolution: RQCI
COMPLIED WITH CMP GIV 521002 MAIN ENT DR CABLE TENSION CK
Discrepancy: 17.84
OAP GIV 521024 blab) Entrance Door Hinge Pins - Inspection
Resolution: COMPLIED WITH CMP GIV 521024 Main Entrance Door Hinge Pins - Inspection
Discrepancy: 17.85
CMPGIV 521022 Main Entrance Door Hinge Pins - Removal / Installation
Resolution: RQCI
REMOVED WORN MAIN ENTRANCE DOOR PINS PARTIt 159BMI0108-1 NSN INSTALLED NEW NEW DOOR
PINS PN 159BM10108-1 NSN. PICKED FOR GAC-BAF STOCK REFER TO SASH815-79980 DATED 5/29/2015. ALL
MAINTENANCE DONE IAW GIV CAW 521022.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 52 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590847
Bill To: JEGE LLC
WO #:
Invoice Number.
Discrepancy: 17.86
CMPGIV 521051 Door Seal Pressure Regulator - Functional Test
Resolution: COMPLIED WITH CMP GIV 521051 Door Seal Pressure Regulator - Functional Test
Discrepancy: 17.87
CMPGIV 527005 Main Entrance Door Warning System - Operational Test
Resolution: COMPLIED WITH CMP GIV 527005 Main Entrance Door Warning System - Operational Test
Discrepancy: 17.88
CMPGIV 527008 Baggage Door Warning System - Operational Test
Resolution: COMPLIED WITH CMP GIV 527008 Baggage Door Warning System - Operational Test
Discrepancy: 17.89
CMPGIV 527012 Tail Comp Door Warning System - Operational Test
Resolution: COMPLIED WITH CMP GIV 527012 Tail Comp Door Warning System - Operational Test
Discrepancy: 17.90
CMPGIV 532005 Cabin Compartment Above Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532005 Cabin Compartment Above Floor - Inspection
Discrepancy: 17.91
CMPGIV 532017 Cockpit Compartment Above Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532017 Cockpit Compartment Above Floor - Inspection
Discrepancy: 17.92
CMPGIV 532019 Cockpit Compartment Below Floor - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 53 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590848
Bill To: JEGE LLC
WO
Invoice Number.
Resolution: COMPLIED WITH CMP GIV 532019 Cockpit Compartment Below Floor - Inspection
Discrepancy: 17.93
CMP GIN, 251109 SEAT ASSEMBLY, PILOT
Resolution:
Discrepancy: 17.94
CAP GP/ 251110 SEAT ASSEMBLY, COPILOT
Resolution:
Discrepancy: 17.95
CMP GIV 532021 Cockpit Compartment Below Pedestal - Inspection
Resolution: COMPLIED WITH CMP GIV 532021 Cockpit Compartment Below Pedestal - Inspection
Discrepancy: 17.96
CMP GIV 532027 Entrance Compartment Behind Panel - Inspection
Resolution: COMPLIED WITH CMP CIV 532027 Entrance Compartment Behind Panel - Inspection
Discrepancy: 17.97
CMP GIV 532029 Entrance Compartment Above Floor -Inspection
Resolution: COMPLIED WITH CMP GIV 532029 Entrance Compartment Above Floor - Inspection
Discrepancy: 17.98
CMP GIN, 532031 Entrance Compartment Brion Floor - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 54 of 123
Printed: 321/2016 11:35:41 AM
■e 322
EFTA00590849
Bill To: JEGE LLC
W()
Invoice Number.
Resolution: COMPLIED WITH CMP GIV 532031 Entrance Compartment Below Moor Inspection
Discrepancy: 17.99
CMPGIV 532033 Entrance Compartment Shelf - Inspection
Resolution: COMPLIED WITH CMP GIV 532033 Entrance Compartment Shelf - Inspection
Discrepancy: 17.100 CMPGIV 532931 Baggage Compartment Above Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532041 Baggage Compartment Above Floor - Inspection
Discrepancy: 17.101 CMPGIV 523001 Baggage Door - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 523001 Baggage Door - Removal /Installation
Discrepancy: 17.102 CMPGIV 532045 Baggage Compartment Behind Panel - Inspection
Resolution: COMPLIED WITH CMP GIV 532045 Baggage Compartment Behind Panel - Inspection
Discrepancy: 17.103 CMPGIV 532050 Engine /APU Fuel Feed Line - Inspection
Resolution:
Discrepancy: 17.104 CMPGIV 532052 Torque Box -Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 55 of 123
Printed: 321/2016 11:35:41 AM
■e 322
EFTA00590850
Bill To: JEGE LLC
WO
Invoice Number.
Resolution: COMPLIED WITH CMP CIV 532052 Torque Box - Inspection
Discrepancy: 17.105 CMP GIV 532055 Fuselage Interior / Wing Attach - Inspection
Resolution: COMPLIED WITH CMP GIV 532055 Fuselage Interior / Wing Attach - Inspection
Discrepancy: 17.106 CMP GIV 532067 Tail Compartment Above Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532067 Tail Compartment Above Floor - Inspection
Discrepancy: 17.107 CMP GIV 532069 Tall Compartment Below Floor- Inspection
Resolution:
Discrepancy: 17.108 CMP GIV 272001 RUDDER CONT SYS--OPS TEST
Resolution:
Discrepancy: 17.109 CMP GIV 273001 ELEVATOR CONTROL SYS, OF'S CK
Resolution:
Discrepancy: 17.110 CMP GIV 272019 Ruddrr ( able Assembly FS 470 - FS 760 (Right)
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 56 of 123
Printed: 321/2016 11:35:41 AM
Rea21
EFTA00590851
Bill To: JEGE LLC
WO U:
Invoice Number:
Resolution: RQCI
COMPLIED WITII O,1P GIV 272019 RUDDER CABLE ASSEMBLY FS 470 - FS 760 (RIGHT) - REMOVAL/
INSTALLATION
Discrepancy: 17.111
CMPGIV 272020 Rudder Cable Assembly FS 470 - FS 760 (Left)
Resolution: RQCI
COMPLIED WITH CMP GIV 272020 RUDDER CABLE ASSEMBLY FS 470 - FS 760 (LEFTI REMOVAL/
INSTALLATION
Discrepancy: 17.112 CMPGIV 273033 CABLE, ELEV CONTROL OUTBD MID
Resolution: RQCI-
COMPLIED WITH CMP GIV 273033 ELEVATOR CABLE ASSEMBLY FS 470 - FS 740 (LEFT) - REMOVAL /
INSTALLATION
Discrepancy: 17.113 CMPGIV 273034 CABLE, ELEV CONTROL INBD MID
Resolution: RQCI
COMPLIED WITH CMP GIV 273034 ELEVATOR CABLE ASSEMBLY FS 470 - FS 740 (RIGHT) - REMOVAL/
INSTALLATION
Discrepancy: 17.114 CMPGIV 532070 Shear Clips Aft Fuselage - Inspection
Resolution: COMPLIED WITH CMP GIV 532070 Shear Clips Aft Fuselage - Inspection
Discrepancy: 17.115 CMPGIV 533005 Exterior Fuselage - Inspection
Resolution: COMPLIED WITH CMP GIV 533005 Exterior Fuselage - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 57 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590852
Bill To: JEGE LLC
WO th
Invoice Number.
Discrepancy: 17.116 OAP GIV 535008 Nose Compartment / Radome Interior - Inspection
Resolution: COMPLIED WITH CMP GIV 535008 Nose Compartment / Radome Interior - Inspection
Discrepancy: 17.117 CMP GIV 535012 Tau Cone Interior - Inspection
Resolution: COMPLIED WITH CMP GIV 535012 Tail Cone Interior - Inspection
Discrepancy: 17.118 CAP GIV 535004 Tail Cone - Removal / Installation
Resolution: REMOVED TAIL CONE P/N:1159821504-3, S/N:1085 FOR NIAINTENANCEINSTALLED SAME TAIL CONE
P/N:1159B21504-3, S/N:1085. WORK DONE IANT GIV NISG3 CMP 535004 TAILCONE - REMOVAIJ
INSTALLATION. OPS CHECK GOOD.
Discrepancy: 17.119 CMP GIV 562005 Emergency Window Release - Operational Test
Resolution: COMPLIED WITH CMP GIV 562005 EMERGENCY WINDOW RELEASE MECHANISM (INTERNAL AND
EXTERNAL) - FUNCTIONAL TEST.
Discrepancy: 17.120 CMP GIV 562007 WINDOW LEAK-CHECK
Resolution: COMPLIED WITH CMP GIV 562007 EMERGENCY EXIT AND CABIN WINDOWS - LEAK CHECK.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 58 of 123
Printed: 321/2016 11:35:41 AM
Ildr:322
EFTA00590853
Bill To: JEGE LLC
WO tl:
Invoice Number.
Discrepancy: 17.121 CMPGIV 571064 Wing to Fuselage Attach (Left) - VLsual Con- Damage Insp
Resolution: COMPLIED WITH CMP GIV 571064 Wing to Fuselage Attach (Left) - Visual Corr Damage Insp
Discrepancy: 17.122 CMPGIV 571065 Wing to Fuselage Attach (Right) - Visual Corr Damage hup
Resolution: COMPLIED WITH CMP GIV 571065 Wing to Fuselage Attach (Right) - Visual Corr Damage Insp
Discrepancy: 17.123 CMPGIV 783005 Engine Thrust Reverser (Left) - Inspection
Resolution: COMPLIED WITH CMP GIV 783005 Engine Thrust Reverser (Left) - Inspection
Discrepancy: 17.124 CMPGIV 783006 Engine Thrust Reverser (Right) - Inspection
Resolution: COMPLIED WITH CMP GIV 783006 Engine Thrust Reverser (Right) - Inspection
Discrepancy: 17.125 CMPGIV 783009 Engine Thrust Reverser (Left) - Operational Test
Resolution: COMPLIED WITH CMP GIV 783009 Engine Thrust Reverser (Left) - Operational Test
Discrepancy: 17.126 CMPGIV 783010 Engine Thrust Reverser (Right) - Operational Test
Resolution: COMPLIED WITH CMP GIV 783010 Engine Thrust Reverser (Right) - Operational Test
Discrepancy: 17.127 ACCOMPLISH THE 24 MONTH AVIONICS CMPTASKS BELOW:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 59 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590854
Bill To: JEGE LLC
WON:
Invoice Number.
Resolution: ACCOMPLISHED THE 24 MONTH AVIONICS CMP TASKS BELOW: 17.127 THRU 17.151
Billing Method
Hours
Rate
Total
Parts USD:
Time and Material
$931.65
Total USD:
$931.65
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
17.12701
7020116-1
BATTERY PACK, NAV COMPUTER
1
$31055
$31055
17.12712
7020116-1
BATTERY PACK, NAV COMPUTER
2
$31055
$621.10
Discrepancy: 17.128 CMPGIV 236010 L Wing Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236010 Static Discharger Wick (Left Wing) - Resistance Check
Discrepancy: 17.129 CMPGIV 236011 R Wing Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236011 Static Discharger Wick (Right Wing) - Resistance Check
Discrepancy: 17.130 CMPGIV 236014 L Hz Stab Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236014 Static Discharger Wick (Left Horizontal Stabilizer) - Resistance Check
Discrepancy: 17.131 CMPGIV 236015 R Hz Stab Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236015 Static Discharger Wick (Right Horizontal Stabilizer) - Resistance Check
Discrepancy: 17.132 CMPGIV 236016 Vert Stab Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236016 Static Discharger Wick (Vertical Stabilizer) - Resistance Check
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 60 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590855
Bill To: JEGE LLC
WO 4:
Invoice Number.
Discrepancy: 17.133 CMP GIV 236020 Tall Cone Static Discharger Wick - Resistance Check
Resolution: COMPLIED WITH CMP GIV 236020 Static Discharger Wick (Tail Cone) - Resistance Check
Discrepancy: 17.134 CMP GIV 237041 CVR Underwater Locator Beacon - Functional Test
Resolution: COMPLIED WITH CMP GIV 237041 CVR UNDERWATER LOCATOR BEACON (DK100/ DK120
OPERATIONAI,
TEST. BATTERY EXPIRATION DATE JAN 2017.
Discrepancy: 17.135 CMP GIV 237047 CVR Underwater Locator Beacon - Battery Voltage Check (DK100 / DK120)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.136 CMP GIV 237005 CVR Unit - Removal / Installation
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.137 CMP GIV 237030 CVR Underwater Locator Beacon - Removal / Installation (DK120)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.138 CMP GIV 237048 CVR Underwater Locator Beacon - Switch Cleaning (DK100/ DK120)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 61 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590856
Bill To: JEGE LLC
WO ti:
Invoice Number.
Discrepancy: 17.139 CMP GIV 243189 Battery Circulating Fan - Operational Test
Resolution: COMPLIED WITH CMP GIV 243189 Battery Circulating Fan - Operational Test
Discrepancy: 17.140 CMP GIV 256112 ELT Registration (NO.2 RAFT)
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.141 CMP GIV 342037 Compass Swing No. 1
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.142 CMP GIV 342038 Compass Swing No. 2
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Discrepancy: 17.143 CMP GIV 346031 FMS Navigation Computer No. 1 - Battery Pack Replacement
Resolution: COMPLIED WITH CMP GIV 346031 FMS NAVIGATION COMPUTER NO. 1 - BATTERY PACK REPLACEMENT,
REMOVED FMS 81 BATTERY P/N 7020116-1
NSN. INSTALLED NEW FhLS #1 BATTERY P/N 7020116-1 S/N
NSN RECEIVED FROM HONEYWELL INTERNATIONAL REFERENCE FAA FORM 8130-3 FORM TRACKING
NUMBER 20150000713417Y14 8004388560-10; WORK ORDER WEPO15-02211; APPROVAL AUTH
ODA-602216-NM; DATED 19/MAY/2015.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 62 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590857
Bill To: JEGE LLC
WO N:
Invoice Number:
Discrepancy: 17.144 CMP GIV 346015 FMS Navigation Computer No. 1 - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 346015 FMS NAVIGATION COMPUTER NO. 1 - REMOVAL! INSTALLATION.
REMOVED FMS NAV COMPUTER P/N 7018879-03014 S/N 95120669. REINSTALLED ORIGINAL FMS NAV
COMPUTER #1. REFERENCE
FOR OPERATIONAL CHECK.
Discrepancy: 17.145 CMP GIV 349800 Flight Management System No. 1 - Operational Check
Resolution: COMPLIED WITH CMP GIV 349800 Flight Management System No. 1 - Operational Check
Discrepancy: 17.146 CMP GIV 346032 FMS Navigation Computer No. 2 - Batter). Pack Replacement
Resolution: COMPLIED WITH CMP GIV 346032 FMS NAVIGATION COMPUTER NO. 2 - BATTERY PACK REPLACEMENT.
REMOVED FMS #2 BATTERY P/N 7020116-1 S/N NSN. INSTALLED NEW FMS #2 BATTERY P/N 7020116-1 S/N
NSN RECEIVED FROM HONEYWELL INTERNATIONAL REFERENCE FAA FORM 8130-3 FORM TRACKING
NUMBER 20150000713417Y14 8004388560-10; WORK ORDER WEPO15-02211; APPROVAL AUTH
ODA-602216-NM; DATED 19/MAY/2015.
Discrepancy: 17.147 CMP GIV 346016 FMS Navigation Computer No. 2 - Remo\ al / Installatian
Resolution: COMPLIED WITH CMP GIV 346015 FMS NAVIGATION COMPUTER NO. 2 - REMOVAL! INSTALLATION.
REMOVED FMS NAV COMPUTER PIN 7018879-03014 S/N 99082387. REINSTALLED ORIGINAL FMS NAV
COMPUTER #2. REFERENCE
FOR OPERATIONAL CHECK.
Discrepancy: 17.148 CMPGIV 349801 Flight Management System No. 2 - Operational Check
Resolution: COMPLIED WITH CMP GIV 349801 Flight Management System No. 2 - Operational Check
Discrepancy: 17.149 CMP GIV 346033 FMS Navigation Computer No. 3 - Battery Pack Replacement
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 63 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 332
EFTA00590858
Bill To: JEGE LLC
WO It:
Invoice Number:
Resolution: COMPLIED WITH CMP GIV 346033 FMS NAVIGATION COMPUTER NO. 3 - BATTERY PACK REPLACEMENT.
REMOVED FILLS #3 BATTERY P/N 7020116-1 S/N NSN. INSTALLED NEW FMS #3 BATTERY P/N 7020116-1 S/N
NSN RECEIVED FROM HONEYWELL INTERNATIONAL REFERENCE FAA FORM 8130-3 FORM TRACKING
NUMBER 20150000713417Y14 8004388560-10; WORK ORDER WEPO15-02211; APPROVAL AUTH
ODA-602216-NM; DATED 19/N1AT/2015.
Discrepancy: 17.150 CMPGIV 346017 FMS Navigation Computer No. 3 - Removal Installation
Resolution: COMPLIED WITH CMP GIV 346017 FMS NAVIGATION COMPUTER NO. 3 - REMOVAL / INSTALLATION.
REMOVED FILLS NAV COMPUTER P/N 7018879-03014 S/N 95120716. REINSTALLED ORIGINAL FMS NAV
COMPUTER #3. REFERENCE
FOR OPERATIONAL CHECK.
Discrepancy: 17.151 CMP GIV 349803 Flight Management System No. 3 - Operational Check
Resolution: COMPLIED WITH CMP GIV 349803 Flight Management System No. 3 - Operational Check
Item: 18
24 MONTH CMP TASKS DISCREPANCIES
Team Manager.
Charles Helwig
Customer Coordinator.
Vinny Cicala
Part/Model a:
AC Serial No./rail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 18.1
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND A WIRE HARNESS LYING ON
HYDRAULIC LINE AFT OF FLIGHT SIDE RESERVOIR.
Resolution: REMOVED PIECES OF OLD WIRE TYE AND INSTALLED 1 EA NEW TYE WRAP PN. TY28 FROM GAC-BAF
STOCK TO MISSING POSITION ON WIRE HARNESS AFT OF FLIGHT RESOVOIR
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
0.37
O
$132.00
$48.84
Labor USD:
Time and Material
OT
0.15
O
$198.00
$29.70
Total USD:
$78.54
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 64 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590859
Bill To: JEGE LLC
WO It:
Invoice Number.
Discrepancy: 182
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND WIRE HARNESS ON AFT SIDE
OF APU COMPARTMENT HAS WIRE TYE SUPPORT BROKEN.
Resolution: REPLACED MISSING WIRE TYE AFT SIDE OF APU COMPARTMENT P11. TY27 FROM GAC STOCK. NO
OTHER DAMAGE NOTED.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
0.46
$132.UU
$60.72
Thal USD:
$60.72
Discrepancy: 183
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND CANNON PLUG BACK SHELL
MISSING PIECES R/H SIDE BLEED AIR DUCT.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
5.87
tg)
$132.00
$774.84
Total USD:
$774.84
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
18.312
NIS3106FIIS-3S
CONNECTOR
1
$0.00
50.00
Step: 18.3.1
Waiting
Insp
RECIEVED INCORRECT CONNECTOR. RESEARCHED THE CONNECTOR AND
FOUND IT LIST ON CUSTOMER'S OUTFITTER DWG: WESTERN
COMMANDER, INC DWG/S: 08030131 WD BLEED AIR CONTROL MONITOR.
FOUND CABLE IDENTIFIER: HX14A20 TO CONNECTOR WITH BROKEN
BACKSHELL. PLACED R/H ENGINE BLEED AIR PRECOOLER ON ORDER.
Discrepancy: 18.4
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND THE LEFT AND RIGHT
PRECOOLER DUCT INSPECTION WINDOWS CRACKED AND CRAZED AND MISSING WINDOW
MOUNT RING.
Resolution: REMOVED CRACKED AND CRAZED LEFT AND RIGHT INSPECTION WINDOWS P/N 1159ACP40008-I3 NSN.
REMOVED TORN RIGHT HAND GASKET P/N 1159AC40040-37 NSN. INSTALLED NEW LEFT AND RIGHT HAND
INSPECTION WINDOWS P/N 1159ACP40008-13 NSN. INSTALLED NEW RH GASKET P/N 1159AC40040-37.
INSPECTION WINDOWS RECIEVED FROM GULFSTREAM AEROSPACE CORPORATION, REFERENCE
CERTIFICATE OF CONFORMANCE WITH PURCHASE ORDER SAP015-17426 DATED 5/7/2015. GASKET
RECIEVED FROM GULFSTREAM AEROSPACE CORPORATION, REFERENCE FAA FORM 8130-3 WITH FORM
TRACKING NUMBER 20141130024044 DATED 30 NOV 2014. ALL WORK DONE IN REFERENCE TO GAC
DRAWING 1159ACP40002 REV B.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
239
th)
$132.00
$315.48
Labor USD:
Time and Material
OT
0.50
67
$198.00
$99.00
Parts USD:
Time and Material
$1,772.34
Total USD:
$2,186.82
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 65 of 123
Printed: 321/2016 11:35:4IAM
■e 322
EFTA00590860
Bill To: JEGE LLC
WO tt:
Invoice Number.
Parts:
Ref. No.
Part number.
Description
Quantity
Sell price USD
Extended USD
18.4 #1
1159AC40040-37
GASKET, AIR COND HEAT EXCH
1
51,450.48
$1,450.48
INLET
18.4 N2
1159ACP40008-13
COVER
2
5160.93
$321.86
Discrepancy: 18.5
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND THE LEFT AND RIGHT
PRECOOLER DUCT MOUNT FLANGE HARDWARE CORRODED.
Resolution: REMOVED CORRODED HARDWARE ON LH AND RH PRECOOLER DUCT MOUNT FLANGES AND REPLACED
WITH NEW HARDWARE P/N: NAS6603-3. NEW HARDWARE RECEIVED FROM GULFSTREAM STOCK. WORK
DONE HAW GIV MM 21.00.00.
Billing Method
Hours
Rate
Total
Labor USD.
Time and Material
ST
4.22
@
$132.00
$557.04
Parts USD:
Time and Material
$112.32
Total USD:
$669.36
Parts:
Rel. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
18.5 #1
NA56603-3
BOLT, CLOSE TOLERANCE HEX
31
$0.78
$24.18
HEAD
18.5 #2
NAS1149D0316H
WASHER
72
$0.78
$56.16
18.5 #3
NA56603-3
BOLT, CLOSE TOLERANCE HEX
41
50.78
$31.98
HEAD
Step: 18.5.1
Completed
STARTED REMOVING CORRODED HARDWARE ON RH PRECOOLER DUCT
MOUNT FLANGE AND REPLACED WITH NEW HARDWARE P/N: NAS6603-3.
NEW HARDWARE RECEIVED FROM GULFSTREAM STOCK. WORK DONE HAW
GIV MM 21-00-00.
Discrepancy: 18.6
WHILE C/W CMP GIV 532017 COCKPIT COMPARTMENT ABOVE FLOOR - INSPECTION NOTED L/H
AND R/H FIRE PULL HANDLES HAVE PAINT MISSING FROM THE "L" & "R" ON THE HANDLES
Resolution: TOUCHED UP MISSING COLOR ON THE IJII AND R/Ii FIRE PULL HANDLES IN THE COCKPIT USING
GRAVEOGRAPH WHITE #32808 ENGRAVERS ENAMEL
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
139 O
$132.00
$183.48
Total USD:
$183.48
Discrepancy: 18.7
WHILE C/W CMP 532069 TAIL COMPARTMENT BELOW FLOOR INSP NOTED ELEVATOR AFT LB
CABLE WORN BEYOND LIMITS.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 66 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590861
Bill To: JEGE LLC
WO #:
Invoice Number.
Resolution: -RQCI-
REMOVED WORN INBOARD ELEVATOR CABLE (ES 470 THROUGH FS 740) P/N UNK SIN NSN. INSTALLED
NEW CABLEASSY P/N 1159SB20431-37 S/N NSN. REFERENCE 8130-3 FORM TRACKING NO. 20150513074315
DATED 5/13/2015 FROM GAC-SAV APPROVAL/AUTHORIZATION # ODA-511131-CE. ALL WORK PERFORMED
IA.W GIV CMP 273034. CABLES TENSIONED JAW GIV CMP 273034 AND 273033.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
9.68
@
$132.00
$1,277.76
Parts USD:
Time and Material
$179.97
Total USD:
$1,457.73
Parts:
Ref. No.
Pan number:
Description
Quantity
Scll puke Vtil)
Extended USD
18.7 NI
11595B20431-37
SWAGE CABLEASSY ELEVATOR
1
5'68.27
$168.27
18,712
MS21256-I
CLIP
IS
$0.7%
$11.70
Step: 18.7.1
Completed
REMOVED WORN INBOARD ELEVATOR CABLE (FS 470 THROUGH FS 740)
P/N UNK S/N NSN. INSTALLED NEW CABLEASSY P/N 1159SB20431.37 S/N NSN.
REFERENCE 8130-3 FORM TRACKING NO. 20150513074315 DATED 5/13/2015
FROM GAC-SAV APPROVAL/AUTHORIZATION 1 ODA-511131-CE. ALL WORK
PERFORMED I.A.W GIV CMP 273034. CABLES HAVE NOT YET BEEN
TENSIONED.
Discrepancy: 18.8
WHILE C/W CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND 2 RIVITS WITH MISSING
HEADS JUST FWD OF RAM AIR INLET ON THE OH SIDE
Resolution: REMOVED 4 EACH RIVETS JUST FWD OF RAM AIR INLET. 2 EACH ON RH SIDE. 2 EACH ON LH SIDE.
REPLACED WITH NAS1921B4 RIVETS FROM GAC STOCK. ALL WORK PERFORMED IA.W GIV SRM 5142-00.
REF GAC. BP. 1159B21871 REV. D
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.55
@
$132.00
$336.60
Parts USD:
Time and Material
$15.14
Total USD:
$351.74
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
18.8 NI
NAS1921B04-04
RIVET
2
$1.81
$3.62
18.812
NAS1921B04-03
RIVET
2
$1.90
$3.80
18.8 #3
NAS1921B04-05
RIVET
3
$1.94
$5.82
18.814
NAS1921B04-03
RIVET
1
$1.90
$1.90
Discrepancy: 18.9
WHILE C/W CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND SEVERAL SCREWS
LOOSE ON API) EXAUST SHIELD.
Resolution: REMOVED ACCESS COVER ON INNER SURFACE OF APLI ACCESS DOOR ADDED 1 NAS1149C0363R WASHER
TO EACH HEATSHIELD ATTACH FASTENER AND RETORQUED FASTENERS IN ACCORDANCE WITH GIV
SRM51-41.00. REINSTALLED ACCESS COVER.
Billing Method
Hours
Rate
Total
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_VANkOrderPreliminaryInvoice.rm 2011
Page 67 of 123
Printed: 3/21/2016 II:35:41AM
Rd 331
EFTA00590862
Bill To: JEGE LLC
WO #:
Invoice Number:
Labor USD:
Time and Material
ST
4.44
(#
$132.00
$586.08
Parts USD:
Time and Material
$12.48
Total USD:
5598.56
Parts:
Ref. No.
Pan number:
Description
Quantity
Sell price USD
Extended USD
18.941
NAS11491:0363R
WASHER
14
$0.78
$10.92
18.912
MS21043-3
NUT
2
$0.78
$1.56
Discrepancy: 18.10
WHILE CAV CMPGIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND AFT FUSELAGE BELLY
DRAIN HOLE APPROX. F.S. 605 WITH MINOR CORROSION AROUND HOLE OPENING.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
I.80
@
$132.00
$237.60
Parts USD:
Time and Material
$18.64
Total USD:
$256.24
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
18.1011
515X333-20Z
2 OZ TOUCHUP KIT, GREEN EPDXY
1
$18.64
$18.[ADDRESS REDACTED]ep: 18.10.1
Completed
REMOVED MINOR CORROSION AROUND AFF FUSELAGE LH BELLY DRAIN
HOLE AT APPROX. KS. 605. BY HAND WITH SCOTCH BRITE, APPLIED
ALODINE, AND PRIMER AS REQUIRED. ALL WORK DONE IN ACCORDANCE
WITH GAC GIV SRM 51-13-10, AND 51-21-21 AND 51-07-10.
Discrepancy: 18.11
WHILE C/W CMPGIV 532069 TAIL COMPARTMENT BELOW FLOOR- INSPECTION FOUND OB ELEV
CABLE IN MLG WELL WELL HAS IMPROPER SIZE TURNBUCKLE INSTALLED.
Resolution: RQCI
VERIFIED CORRECT LENGTHS OF OUTBOARD, FORWARD AND AFT ELEVATOR CABLES. UPON FURTHER
INVESTIGATION FOUND TURNBUCKLE P/N M52125-6L TO BE ACCEPTABLE FOR USE. WORK PERFORMED
JAW GAC-DOC 1 1159SB20431 REV C, SHEET 2, 1159C20078 REV D, SHEET 2 AND 1159SB20430 REV B, SHEET
2.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
3.92
(#
$132.00
$517.44
Total USD:
$517.44
Discrepancy: 18.12
WHILE CAV CMPGIV 535008 NOSE COMPARTMENT/ RADOME INTERIOR - INSPECTION FOUND
NOSE RADOME BONDING CONTACT POINTS ON FUSELAGE RUSTED.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 68 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590863
Bill To: JEGE LLC
WO 0:
Invoice Number:
Resolution: REMOVED SURFACE CORROSION ON 4 EACH CONTACT POINTS ON NOSE RADONIE BONDING CONTACT
POINTS ON FUSELAGE. NO PITTING NOTED. CLEANED AND APPLIED PRIMER TO SURROUNDING AREAS
OF CONTACT POINTS. ALL WORK PERFORMED IAM GIV. SRM 51-21-23. 51-13-10.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.00
0
$132.00
$264.00
Total USD:
$264.00
Discrepancy: 18.13
WHILE C/W CMPGIV 535008 NOSE COMPARTMENT/ RADOME INTERIOR - INSPECTION FOUND
NOSE RADOME LATCHES RUSTING.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.63
@
$132.00
$347.16
Total USD:
$357.06
Step: 18.13.1
Completed
REMOVED SURFACE CORROSION ON 4 EACH RADOME HINGES. NO PITTING
NOTED.APPLIEDALODINE TOALUMINUM ALLOY SURFACES. APPLIED
PRIMER COATING TO METAL ALLOY SURFACES. ALL WORK PERFORMED
LAW GIV SRM 51-21-23. 51-13-10.
Step: 18.13.2
Open
OPEN FOR FINAL PAINT
Discrepancy: 18.14
WHILE C/W CMPGIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND PILOTS WINDSHILED
WIPER BLADE DETERIORATED.
Resolution:
Discrepancy: 18.15
WHILE C/W CMPGIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND BOTH PILOTS AND
COPILOTS WINDSHIELD WIPER ARMS AT BASE OF WIPER CONTACTING FUSELAGE SKIN.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
11.45
@
$132.00
$1,511.40
Parts USD:
Time and Material
$3.90
Total USD:
$1,515.30
Parts:
Ref. No.
Parr number:
lkscription
Quantity
Sell price USD
Extended USD
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 69 of 123
Printed: 321/2016 II:35:41AM
Rd: 322
EFTA00590864
Bill To: JEGE LLC
Farts:
WO 1/:
Invoice Number.
Ref. No.
Pan number:
Description
Quantity
Sell price USD
Extended USD
18.1501
NAS1580A3T6
SCREW
S
$0.78
$3.90
Step: 18.15.1
Waiting
REMOVED THE LAI AND Rai WINDSHIELD WIPER ARMS PIN N/A SIN NSN.
Insp
FOUNDTHE ARM MOUNTING GUIDE INSTALLED INCORRECTLY REMOVED
AND INSTALLED THE ARM MOUNTING GUIDE CORRECTLY. FOUND
CORRLSION ON THE MOUNTING PANEL FOR THE L/H AND Rill WIPER
MOTORS. ALL WORK DONE JAW GULFSTREAP4 GIV MM 30-04-00.
Step: 18.15.2
Completed
REMOVED 1./11 WINDSHIELD WIPER MOTOR ASSY. P/N: XW23796-1 S/N: 343.
MW GIV CMP 304005. REMOVED R/H WINDSHIELD WIPER MOTOR ASSY. PIN:
XW23796-2 S/N: 336 WW GIV CMP 304006.
Discrepancy: 18.16
WHILE C/W CMP GIV 216098 AIR CYCLE MACHINE COMPRESSOR OUTLET OVERHEAT SWITCH
(RIGHT) - TRIP POINT CHECK FOUND BOTH TEMP AND RESISTANCE CHECKS FAILED FOR THIS
UNIT.
Resolution: REMOVED OUTLET OVERHEAT SWITCH WITH PIN 1173T0458, SIN 1914. INSTALLED A NEW OUTLET
OVERHEAT SWITCH WITH P/N 1173T0458 SIN 2086. REFERENCE 8130-3 WITH FORM TRACKING d
20141124015239 DATED 24 NOV 2014 FROM GULFSTREAM AEROSPACE CORP. CRS? ODA-511131 . ALL
WORK DONE IN ACCORDANCE WITH GV AMA 21-01.09 AND GV CMP 216096 SW R ACM COMPRESS OUT
O/11EAT SWITCH OP CHECKS GOOD
UPDATE CMP AS REQUIRED
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
3.65
@
$132.00
$481.80
Parts USD:
Time and Material
$5,413.56
Total USD:
$5,895.36
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
18.1641
11737'0458
OVERHEAT SWITCH, ACM
1
$5,412.00
$5,412.00
COMPRESSOR OUTLET PILOT
OVERHEAD
18.1642
59026E112
O'RING
2
$0.78
$1.56
Discrepancy: 18.17
CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND FWD GOGO BIZ ANTENNA (AFT
BELLY) HAS MISSING AND DETERIORATED EROSION TAPE
Resolution: REMOVED OLD DETERIORATED EROSION TAPE, CLEANED AFFECTED AREA WITH ISOPROPYL
ALCOHOL AND REPLACED WITH NEW EROSION TAPE AS REQUIRED.
Labor USD:
Billing Method
Hours
Rate
Total
Time and Material
ST
1.07
d/
$132.00
$141.24
Total USD:
$141.24
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 70 of 123
Printed: 3/21/2016 II:35:41AM
Rd 322
EFTA00590865
Bill To: JEGE LLC
WO #:
Invoice Number:
Discrepancy: 18.18
WHILE C/W CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND NOSE SKIN FLANGE AFT
OF RADOME AT 11:00 OCLOCK POSITION TO BE TORN APROX 1/4" LONG
Resolution: UPON FURTHER INVESTIGATION OF NOSE FLANGE.FOUND AREA OF SEALANT TORN. REAPPLIED
SEALANT TO AFFECTED AREA. ALL WORK PERFORMED LAW SRM51-22-00 . GAMPS 7115.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.01
(F)
$132.00
$265.32
Total USD:
$265.32
Discrepancy: 18.19
WHILE C/W CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND FWD OXYGEN BLOW OUT
DISK TO BE UNSERVICABLE.
Resolution: REMOVED UNSERVICABLE O2 BLOWOUT DISC. INSTALLED NEW DISC P/N 171-10 NSN RECEIVED FROM
AVOX SYSTEMS. REF COC REFERENCE # 731642 DATED 26JAN2012. WORK DONE lAW GAC BP 1159AC40826
REV B.
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
2.86
@
$132.00
$377.52
Parts USD:
Time and Material
$21.24
Total USD:
$398.76
Parts:
Ref. No.
Part number:
Description
Ql1.111111>
Sell price USD
Extended USD
1&1981
171-10
INDICATOR. OXYGEN DLSC
1
$21.24
$21.24
Discrepancy: 18.20
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND THE COMBINED HYDRAULIC
SYSTEM RESERVOIR LEAKING EXTERNALLY AT THE AFT SIDE OF THE RESERVOIR.
Resolution:
Discrepancy: 18.21
DURING TAIL COMPARTMENT ABOVE FLOOR INSPECTION FOUND THE FLIGHT SIDE RESERVOIR
LEAKING EXTERNALLY AT THE AFT SIDE OF THE RESERVOIR.
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 71 of 123
Printed: 321/2016 II:35:41AM
Ret322
EFTA00590866
Bill To: JEGE LLC
WO #:
Invoice Number.
Discrepancy: 18.22
WHILE C/W CMP GIV 562005 EMERGENCY WINDOW RELEASE - OPERATIONAL TEST FOUND RH #1
E-WINDOW FAILED RELEASE CHECK RELEASE TENSION TOO LOW.
Resolution: RQCI
PERFORMED PULL TEST AND FOUND ALL FOUR WINDOW RELEASE LEVERS TO BE OVER TIGHTENED,
AND ROLLERS ON WINDOW RELEASE LEVERS TO BE OUT OF RIG. ADJUSTED WINDOW RELEASE LEVER
SET SCREWS AND CONTROL RODS.
PERFORMED E EXIT RIGGING AND FUNCTIONAL CHECK TAW GULFSTREAM GIV MM 56-22-00 WITH NO
FURTHER DISCREPANCIES NOTED.
RECEIVED O.K. TO INSTALL AND ACCOMPLISHED WINDOW R&I TAW GULFSTREAM GIV MM CH 52-22-00.
PERFORMED E EXIT WINDOW LEAK CHECK LAW GULFSTREAM GIV MM CH 56-21-00. NO FURTHER
DEFECTS NOTED.
Labor USD:
Billing Method
Hours
Rate
Total
Time and Material
ST
9.20
$132.00
$1,214.40
Total USD:
$1,214.40
Discrepancy: 18.23
WHILE C/W CMP GIV 562005 EMERGENCY WINDOW RELEASE - OPERATIONAL TEST FOUND RH # 2
WINDOW LEAKING FROM LEADING AND TRAILING EDGES.
Resolution: RQCI
REMOVED RH #2 E EXIT-WINDOW, CLEANED BED SEAL.RECEIVED O.K. TO INSTALL AND INSTALLED RH
#2 E EXIT-WINDOW TAW GIV M. CH 52-22-00.
PERFORMED E EXIT WINDOW LEAK CHECK RSV GULFSTREAM GIV MM CH 56-21-00. NO FURTHER
DEFECTS NOTED.
Labor USD:
Billing Method
Hours
Rate
Total
Time and Material
ST
7.46
(P)
$132.00
$984.72
Total USD:
$984.72
Discrepancy: 18.24
WHILE C/W CMP GIV 532031 ENTRANCE COMPARTMENT BELOW FLOOR - INSPECTION FOUND
INDENTATIONS ON TOP OF FLOORBOARD FLR-15
Resolution:
Discrepancy: 18.25
CMP GIV 533005 EXTERIOR FUSELAGE - INSPECTION FOUND PILOTS PITOT HEAD HAS DENTED TIP
OPENING
Resolution:
For detail description of the work complied wilh see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 72 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590867
Bill To: JEGE LLC
WO #:
Invoice Number.
Item: 19
36 MONTH CMP TASKS (GIV SN 1085)
Team Manager.
Charles Helwig
Customer Coordinator:
Vinny Cicala
Pan/Model #:
AC Serial No./Tail No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 19.1
36 MONTH CAP TASKS (LABOR ONLY)
Resolution:
ACCOMPLISH 36 MONTH CMP TASKS. (EXHIBIT 3)
NOTES:
CORRECTION OF DISCREPANCIES IS NOT INCLUDED IN THE QUOTED PRICE.
DUE LIST PROJECTED THROUGH 31 DECEMBER 2016.
IF CADMIUM PLATING DEGRADATION IS FOUND DURING THE WING TANK INTERNAL
INSPECTION, ESTIMATED REPAIRS COST CAN BE $35,000 IN LABOR AND MATERIALS DEPENDING
ON THE CONDITION OF THE AIRCRAFT.
RE: PROPOSAL
-2.3
•» LABOR ONLY
Billing Method
Hours
Raw
Total
Labor USD:
Flat Rate
530,078.75
Total USD:
530,078.75
Discrepancy: 19.2
ACCOMPLISH THE 36 MONTH SERVICE CMP TASKS BEIA)W:
Resolution:
Billing Method
Hours
Raw
I ot.J
Parts USD:
Total USD:
Parts:
Time and Material
S1.00.1.36
51.00436
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
19.2 MI
ACETONE
ACETONE (55 GAL DRUM = 440 PTS
2
SI-58
$3.16
= 365 LBS)
19.2 #2
NA.S754-204
BUSHING
4
$10.53
$42.12
19.2 #3
NA.S754-I27
BUSHING
2
$2238
$44.76
19.2 #4
NA.S75-4-130
BUSHING
2
$23.46
$46.92
19.2 #5
M524665-151
COTTER PIN
15
$0.78
SII.70
For detail description or the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 73 of 123
Printed: 3/21/2016 11:35:41AM
Rd 322
EFTA00590868
Bill To: ,TEGE, LLC
Parts:
WO #:
Invoice Number.
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
19.216
EIS20605R3W4
RIVET
10
$0.78
$7.80
19.217
GAR501AC3-5
RIVET [SEE EIS28605S3W5l
6
$1.03
$6.18
19.218
EIS21075L0SN
NUT PLATE
1
$0.78
$0.78
19.219
NAS1580C3T3
BOLT
30
$0.78
$23.40
19.2 #10
MS27039-1-06
SCREW-MACHINE,PAN HEAD
1
$0.78
$0.78
19.2111
NAS1149D0316H
WASHER
1
$0.78
$0.78
19.2112
PR1440B1-2-654
SEALANT, 6 OUNCE #654 SEMKIT
2
$31.39
$62.78
1/2 HOUR WORK LIFE
19.2113
PR1440B1-2-654
SEALANT, 6 OUNCE. #654 SEEIKIT
4
$31.39
$125.56
1/2 HOUR WORK LIFE
19.2114
PR1440B1.2-654
SEALANT, 6 OUNCE 0654 SEhlKIT
1
$31.39
$31.39
1/2 HOUR WORK LIFE
19.2 #15
NAS1993-3T
SCREW
30
$0.93
$27.90
19.2 #16
NAS1581C3T2
SCREW, FLUSH HEAD 100 DEGREE
15
$0.78
$11.70
SHEAR
19.2 #17
MS24694-552
SCREW - MACHINE, FLAT - CSK
50
$0.78
$39.00
19.2 #18
NAS158IC3T3
SCREW
45
$0.78
$35.10
19.2 #19
PRI440B1-2-654
SEALANT, 6 OUNCE #654 SEEIKIT
2
$31.39
$62.78
1/2 HOUR WORK LIFE
19.2120
PR1440B1-2-654
SEALANT, 6 OUNCE. #654 SKAIKIT
10
$31.39
$313.90
1/2 HOUR WORK LIFE
19.2121
AN960-10
FLAT WASHER
5
$0.78
$3.90
19.2 #22
NAS1149F0332P
WASHER, FLAT STEEL
1
$0.78
$0.78
19.2 #23
515X333-2OZ
2 OZ TOUCHUP KIT, GREEN EPDXY
2
$18.64
$37.28
PRIMER
19.2 #24
A EROSHELLI4
GREASE. 6.6 POUND CAN
1
$63.91
$63.91
Discrepancy: 193
CMPGIV 270101 Stall Barrier /Angle or Attack System - Ops Test
Resolution: COMPLIED WITH CMP GIV 270101 Stall Barrier /Angle of Attack System - Ops Test
Discrepancy: 19.4
CMPGIV 270221 Stall Barrier Dump Valve - Operational Test
Resolution: COMPLIED WITH CMP GIV 270221 Stall Barrier Dump Valve - Operational Test
Discrepancy: 19.5
CMPGIV 272038 Rudder Pedals - Lubrication
Resolution: COMPLIED WITH CMP GIV 272038 Rudder Pedals - Lubrication
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 74 of 123
Printed: 3/21/2016 II:35:41AM
Itc.322
EFTA00590869
Bill To: JEGE LLC
WO ft
Invoice Number.
Discrepancy: 19.6
CMPGIV 275009 Flap Actuator Yoke (Left Inboard) - Inspection
Resolution: COMPLIED WITH CMP GIV 275009 Flap Actuator Yoke (Left Inboard) - Inspection
Discrepancy: 19.7
CMPGIV 275003 Flap (Left) - Removal / Installation
Resolution: RQCI
COMPLIED WITH CMP GIV 275003 Flap (Left) - Removal / Installation
Discrepancy: 19.8
CMPGIV 275010 Flap Actuator Yoke (Right Inboard) - Inspection
Resolution: COMPLIED WITH CMP GIV 275010 Flap Actuator Yoke (Right Inboard) - Inspection
Discrepancy: 19.9
CMPGIV 275004 Flap (Right) - Removal / Installation
Resolution: RQCI:
COMPLIED WITH CMP GIV 275004 FLAP (RIGHT) - REMOVAL/ INSTALLATION
Discrepancy: 19.10
CMPGIV 275011 Flap Actuator Yoke (Left Outboard) - Inspection
Resolution: COMPLIED WITH CMP GIV 275011 Flap Actuator Yoke (Left Outboard) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 75 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590870
Bill To: JEGE LLC
WO #:
Invoice Number.
Discrepancy: 19.11
CMPGIV 275012 Flap Actuator Yoke (Right Outboard) - Inspection
Resolution: COMPLIED WITH CMP GIV 275012 Flap Actuator Yoke (Right Outboard) - Inspection
Discrepancy: 19.12
CMPGIV 275027 Flap Actuator Bushing (Left) - Lubrication
Resolution: COMPLIED WITH CMP GIV 275027 Flap Actuator Bushing (Left) - Lubrication
Discrepancy: 19.13
CMPGIV 275005 Inboard Flap Actuator (Left) - Removal / Installation
Resolution: RQCI
COMPLIED WITH CMP GIV 27.5005 Inboard Flap Actuator (Left) • Removal / Installation
Discrepancy: 19.14
CMPGIV 275007 Outboard Flap Actuator (Left) - Removal / Installation
Resolution: RQCI
COMPLIED WITH CMP GIV 275007 Outboard Flap Actuator (Left) - Removal / Installation
Discrepancy: 19.15
CMPGIV 275028 Flap Actuator Bushing (Right) - Lubrication
Resolution: COMPLIED WITH CMP GIV 275028 Flap Actuator Bushing (Right) - Lubrication
Discrepancy: 19.16
CMPGIV 275006 Inboard Flap Actuator (Right) - Removal / Installation
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 20I I
Page 76 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590871
Bill To: JEGE LLC
WO 8:
Invoice Number.
Resolution: RQCI
COMPLIED WITH CMP GIV 275006 Inboard Flap Actuator (Right) - Removal / Installation
Discrepancy: 19.17
CMP GIV 275008 Outboard Flap Actuator (Right) - Removal / Installation
Resolution: RQCI
COMPLIED WITH CMP GIV 275008 Outboard Flap Actuator (Right) - Removal / Installation
Discrepancy: 19.18
CMP GIV 280005 Fuel Control System - Functional Test
Resolution:
Discrepancy: 19.19
CMP GIV 532007 Forward Cabin Compartment Below Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532007 Forward Cabin Compartment Below Floor - Inspection
Discrepancy: 19.20
CMP GIV 532009 MIdcabin Compartment Below Floor - Inspection
Resolution: COMPLIED WITH CMP GIV 532009 Mldcabin Compartment Below Floor - Inspection
Discrepancy: 19.21
OAP GIV 551019 Horizontal Stabilizer/Elevator (Exterior) (Left) - Inspection
Resolution: COMPLIED WITH CMP GIV 551019 Horizontal Stabilizer / Elevator (Exterior) (Left) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 77 of 123
Printed: 321/2016 11:35:41AM
Rd: 322
EFTA00590872
Bill To: JEGE LLC
WO 41:
Invoice Number.
Discrepancy: 19.22
CMPGIV 273003 Elevator Free Play - Inspection
Resolution: COMPLIED WITH CMP GIV 273003 Elevator Free Play - Inspection
Discrepancy: 19.23
CMPGIV 551020 Horiz Stabilizer/ Elevator (Exterior) (Right) - lnsp
Resolution: COMPLIED WITH CMP GIV 551020 Horiz Stabilizer/ Elevator (Exterior) (Right) - Insp
Discrepancy: 19.24
CMPGIV 551023 Horizontal Stabilizer / Elevator (Interior/ Exterior) (Left) - Inspection
Resolution: COMPLIED WITH CMP GIV 551023 Horizontal Stabilizer / Elevator (Interior/ Exterior) (Left) - Inspection
Discrepancy: 19.25
CMPGIV 551024 Hz Stabilizer/Elevator (Interior/Exterior) (Right) - Imp
Resolution: COMPLIED WITH CMP GIV 551024 Hz Stabilizer/Elevator (Interior/Exterior) (Right) - Insp
Discrepancy: 19.26
CMPGIV 553005 Vertical Stabilizer / Rudder (External) - Inspection
Resolution: COMPLIED WITH CMP GIV 553005 Vertical Stabilizer / Rudder (External) - Inspection
Discrepancy: 19.27
CMPGIV 553007 Vertical Stabilizer / Rudder (Internal) - Inspection
Resolution: RQCI
COMPLIED WITH CMP GIV 553007 Vertical Stabilizer / Rudder (Internal) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 78 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590873
Bill To: JEGE LLC
WO tt:
Invoice Number.
Discrepancy: 19.28
CMPGIV 571011 Wing Front Beam Ili-Lite Collars (Left) - Inspection
Resolution: COMPLIED WITH CMP GIV 571011 Wing Front Beam III-Lite Collars (Left) - Inspection
Discrepancy: 19.29
CMPGIV 261169 SWITCHES, L WG O-TEMP--CK
Resolution: COMPLIED WITH CMP GIV 261169 SWITCHES, L WG O-TEMP--CK
Discrepancy: 19.30
CMPGIV 574005 Wing Leading Edge (Left Inboard) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574005 Wing Leading Edge (Left Inboard) - Removal / Installation
Discrepancy: 19.31
CMPGIV 574011 Wing Leading Edge (Left Center) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574011 Wing Leading Edge (Left Center) - Removal / Installation
Discrepancy: 1932
CMPGIV 574017 Wing Leading Edge (Left Outboard) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574017 Wing Leading Edge (Left Outboard) - Removal / Installation
Discrepancy: 19.33
CMPGIV 571012 Wing Front Beam Hi-Lite Collars (Right) - Inspection
Resolution: COMPLIED WITH CMP GIV 571012 Wing Front Beam Hi-Lite Collars (Right) - Inspection
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 79 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 322
EFTA00590874
Bill To: JEGE LLC
WO 0:
Invoice Number.
Discrepancy: 19.34
CMPGIV 261170 SWITCHES, R WG O-TEMP—CK
Resolution: COMPLIED WITH CMP GIV 261170 SWITCHES, R WG O-TEMP--CK
Discrepancy: 19.35
CMPGIV 574006 Wing Leading Edge (Right Inboard) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574006 Wing Leading Edge (Right Inboard) - Removal / Installation
Discrepancy: 19.36
CMPGIV 574012 Wing Leading Edge (Right Center) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574012 Wing Leading Edge (Right Center) - Removal / Installation
Discrepancy: 19.37
CMPGIV 574018 Wing Leading Edge (Right Outboard) - Removal / Installation
Resolution: COMPLIED WITH CMP GIV 574018 Wing Leading Edge (Right Outboard) - Removal / Installation
Discrepancy: 19.38
CMPGIV 571025 Wing Tank Interior cl.e(t) - Inspection
Resolution: COMPLIED WITH CMP GIV 571025 Wing Tank Interior (Left) - Inspection
Discrepancy: 19.39
CMPGIV 280011) Deluding Procedures
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 80 of 123
Printed: 321/2016 11:35:41 AM
Rea
EFTA00590875
Bill To: JEGE LLC
WO 4:
Invoice Number.
Discrepancy: 19.40
CMPGIV 280018 Fuel Tank (Left) - Leak Check
Resolution:
Discrepancy: 19.41
CMPGIV 282025 Fuel Pickup Screen (Main Left Wing) - Inspection
Resolution: COMPLIED WITH CMP GIV 282025 Fuel Pickup Screen (Main Left Wingi - Inspection
Discrepancy: 19.42
CMPGIV 282026 Fuel Pickup Screen (Alternate Left Wing) - Inspection
Resolution: COMPLIED WITH CMP GIV 282026 Fuel Pickup Screen (Alternate Left Wing) - Inspection
Discrepancy: 19.43
CMPGIV 571003 Wing Fasteners - Cadmium Plating Degradation - Check (Left)
Resolution: COMPLIED WITH CMP GIV 571003 Wing Fasteners Cadmium Plating Degradation - Check (Left)
Discrepancy: 19.44
CMPGIV 571026 Wing Tank Interior (Right) - Inspection
Resolution: COMPLIED WITH CMP GIV 571026 Wing Tank Interior (Right) - Inspection
Discrepancy: 19.45
CMPGIV 280019 Fuel Tank (Right) - Leak Check
Resolution:
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 20I I
Page 81 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590876
Bill To: JEGE LLC
WO 4:
Invoice Number.
Discrepancy: 19.46
CMPGIV 282027 Fuel Pickup Screen (Main Right Wing) - Inspection
Resolution: COMPLIED WITH CMP GIV 282027 Fuel Pickup Screen (Main Right Wing) - Inspection
Discrepancy: 19.47
CMPGIV 282028 Fuel Pickup Screen (Alternate Right Wing) - Inspection
Resolution: COMPLIED WITH CMP GIV 282028 Fuel Pickup Screen (Alternate Right Wing) - Inspection
Discrepancy: 19.48
CMPGIV 571004 Wing Fasteners Cadmium Plating Degradation - Check (Right)
Resolution: COMPLIED WITH CMP GIV 571004 Wing Fasteners - Cadmium Plating Degradation - Check (Right)
Discrepancy: 19.49
ACCOMPLISH THE 36 MONTH AVIONICS CMPTASKS BELOW:
Resolution: ACCOMPLISHED THE 36 MONTH AVIONICS CMP TASKS BELOW: 19.50
Discrepancy: 19.50
CMPGIV 245051 AC / DC Power Distribution System - Functional Test
Resolution: CUSTOMER REQUESTS NO ACTION AT THIS TIME.
Item: 20
36 MONTH COP TASKS DISCREPANCIES
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rpt 2011
Page 82 of 123
Printed: 321/2016 11:35:41 AM
Rd: 322
EFTA00590877
Bill To: JEGE LLC
WO th
Invoice Number.
Team Manager.
Charles Helw ig
Customer Coordinator:
Vinny Cicala
Pan/Model $/:
AC Serial No./Thil No.:
TSN/TSO:
CSN/CSO:
Aircraft Time:
Discrepancy: 20.1
WHILE C/W CMP GIV 571003 WING FASTENERS - CADMIUM PLATING DEGRADATION - CHECK
(LEFT) FOUND DEGRIDATION OF CADMIUM PLATING.
Resolution: CLEANED ALL Lill WING CADMIUM FASTENERS WITH NYLON BRUSH AND NOVEC 7100. PAINTED
FASTENERS WITH FUEL TANK INTEGRAL PAINT 823-011. ALL WORK DONE WW GIV CORROSION
PREVENTION CONTROL MANUAL 57-10-00 AND CNN 571004.
Labor USD:
Labor USD:
Pans USD:
Billing Method
Hours
Rate
Total
Time and Material
ST
47.89
O
$132.00
56,321.48
Time and Material
OT
4.77
O
$198.00
5944.46
Time and Material
$1,708.58
Total USD:
58,974.52
Parts:
Ref. No.
Pan number:
Description
Quantity
Sell price USD
Extended USD
20.1 NI
HFE-7100
SOLVENT, GALLON, NOVEC 7100
2
8854.29
51,708.58
Step: 20.1.1
Completed
Step: 20.1.2
Waiting
rasp
CLEANED AND PAINTED FASTENERS IN MI FUEL BAYS I THRU 4. CLEANED
FASTENERS IN BAYS 13 THRU IS AND LS READY FOR PAINLCLEANED
FASTENERS IN BAYS 5 AND 6 AND IS READY FOR PAINT. ALL WORK DONE
1AW GIV CMP 571004.
CLEANED AND PAINTED FASTENERS IN MI FUEL BAYS 10THROUGH I&
ALL WORK DONE IAW G1V CA1P 571004.
Discrepancy: 202
WHILE C/W CMP GIV 571004 WING FASTENERS- CADMIUM PLATING DEGRADATION -CHECK
(RIGHT) FOUND CADMIUM DEGRADATION.
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
47.18
(8)
$132.00
$6,227.76
Labor USD:
Time and Material
OT
0.30
(8)
$198.00
$59.40
Total USD:
56,287.16
Step: 20.2.1
Completed
CLEANED FASTENERS IN RAI WING INSIDE FUEL PANELS 22-17-14 TO
22-RT-18. ALL WORK DONE lAW CIV MSG-3 CORROSION PREVENTION
CONTROL MANUAL 57-10-00.
Step: 20.2.2
Completed
CLEANED FASTENERS IN RAI WING INSIDE FUEL PANELS 22-F r-8
22-RT-13. ALL WORK DONE 1AW CIV CORROSION PREVENTION CONTROL
MANUAL 57-10-00 AND CMP 571004
Step: 20.2.3
Waiting
PAINTED FASTENERS IN R/H WING INSIDE FUEL PANELS 22-FP-8 TO 22-FP-13.
Insp
ALL WORK DONE IAW CIV CORROSION PREVENTION CONTROL MANUAL
57-10-00 AND CA1P 571004.
Step: 20.2.4
Waiting
CLEANED FASTENERS IN RAI WING INSIDE FUEL PANELS 22-FP-1TO 22-FT.S.
Incp
ALL WORK DONE IAW G1V CORROSION PREVENTION CONTROL MANUAL
57-10-00 AND CMP 571004.
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_VttorkOrderPreliminarylnvoice.rpt 2011
Page 83 of 123
Printed: 321/2016 11:35:41AM
Rd: 322
EFTA00590878
Bill To: JEGE LLC
WO It:
Invoice Number.
Discrepancy: 203
WHILE C/W CMP GIV 553005 VERTICAL STABILIZER / RUDDER (EXTERNAL) - INSPECTION FOUND A
LARGE SPOT OF EXFOLIATION CORROSIONON LH SIDE OF VERTICAL STAB AT BASE
Resolution:
Billing Method
Hours
Rate
Total
Labor USD:
Time and Material
ST
39.46
0
$132.00
$5,208.72
Labor USD:
Time and Material
OT
10.73
0
$198.00
$2,124.54
Parts USD:
Time and Material
$3,060.66
Total USD:
$10,393.92
Parts:
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
20.3N1
1159S1120470-23
DOUBLER
1
$1.061.89
$1,061.89
20.313
NAS1921M05-03
RIVET
2
$3.75
$7.50
20.314
GAR501AB6-4
RIVET
2
$8.59
$17.18
20.315
OSMISIO0B0505
RIVET, OVERSIZE
I
$73.50
$73.50
20.316
0Sh11-SIOOM05-05
RIVET
16
$31.20
$499.20
20.317
NAS1921M05-05
RIVET
8
$6.42
$51.36
20.318
NAS1921M05-03
RIVET
-10
$3.75
$150.00
20.319
NAS1921M05-04
RIVET
6
$4.28
$25.68
20.3110
NAS1921M04-04
RIVET. HUCK FLUSH HEAD
2
$6.70
$13.40
20.3 III
NAS1921M04-05
RIVET
30
$4.47
$134.10
20.3113
OSMIS1003406-06
RIVET
3
$30.90
$92.70
20.3114
NIS21042L3
NUT
8
$0.78
$6.24
20.3115
MS90353-0505
RIVET
14
$1.41
$19.74
20.3116
GAR501AB6-6
RIVET
2
$16.29
$32.58
20.3117
GARSOIAB6-7
RIVET
2
$14.32
$28.64
20.3118
NAS1921M06S05
RIVET. SINGLE ACTION HUCK
2
$6.00
$12.00
20.3119
PS87082-654
SEALANT. 3.5 OUNCE #654 SEMKIT
I
$69.89
$69.89
(MEETS SPEC MIL-PRF-81733 REV D
05/98)
20.3120
NASI921M04-06
RIVET
5
$4.12
$20.60
20.3121
NAS1921M04-05
RIVET
9
$4.47
$40.23
20.3122
NAS1921M04-06
RIVET
9
$4.12
$37.08
20.3123
NAS1921M05-04
RIVET
23
$4.28
$98.44
20.3124
()Shit-4;10080401
OVERSIZE RIVET
2
$8.00
$16.00
20.3125
(kShIlS10080505
RIVET. OVERSIZE
2
$73.50
$147.00
20.3126
PS870112-654
SEALANT, 3.5 OUNCE *654 SEMKIT
1
$69.89
$69.89
(MEETS SPEC MIL-PRE-81733 REV D
05/98)
20.3127
PRI44081-2-654
SEALANT, 6 OUNCE 1654 SEMKIT
1
$31.39
$31.39
1/2 HOUR WORK LIFE
20.3128
NASI149D0316K
WASHER-FLAT ANODIZED ALUM
8
$0.78
$6.24
20.3129
NASI581C3R3
BOLT
1
$2.14
$2.14
20.3130
NASI581C3R2
BOLT
1
$0.99
$0.99
20.3 #31
NAS1581C3R4
BOLT, FLSHR HD
1
$0.78
$0.78
20.3132
NASI581C3R5
BOLT, FLSHR HD
1
$0.86
$0.86
20.3133
NAS1149D0332K
WASHER, FLAT ANODIZED
5
$0.78
$3.90
ALUMINUM
20.3134
NAS114900332,1
WASHER
5
$0.78
$3.90
For detail description of the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document are in US Dollars (USD).
GAC_VriarkOrderPreliminaryInvoice.rpt 2011
Page 84 of 123
Printed: 3/21/2016 11:35:41AM
Rd 332
EFTA00590879
Bill To: JEGE LLC
Parts:
WO tl:
Invoice Number.
Ref. No.
Part number:
Description
Quantity
Sell price USD
Extended USD
20.3035
NA51149D0363H
WASHER
5
$0.78
$3.90
20.3036
515X333-20Z
2 OZ TOUCHUP KIT. GREEN EPDXY
1
$18.64
$18.64
PRIMER
20.3037
08611-S100/005-04
RIVET
4
$58.71
$234.84
20.3038
P,S.1370B1-2DAB-KIT
SEALANT, 50 GRAM KIT (CUP &
1
$28.24
$28.24
SYRINGE) (MEETS SPEC
MIL-PRF-81733 REV D 05198)
(INTERNAL ONLY1
Step: 20.3.1
Completed
REMOVED PAINT AND A FASTENER AT DISCREPANT AREA. STARTED TO
MECHANICALLY REMOVE CORROSION. FOUND CORROSION DAMAGE TO
EXTERNAL DOUBLER TO EXTEND THROUGH OVER 50% OF MATERIAL
CAUSING DOUBLER TO BE UNSERVICEABLE.
ALL WORK DONE TAW GIV SRM 51.13.21 AND 51-42-00.
Step: 20.3.2
Completed
REMOVED REMAINING FASTENERS AND SCREWS RETAINING DOUBLER.
UPON REMOVAL OF DOUBLER. FOUND VERTICAL STAB SKIN UNDER MATED
DOUBLER TO HAVE MULTIPLE AREAS OF SURFACE CORROSION.
MECHANICALLY REMOVED CORROSION USING FINE ABRASIVES.
ALL WORK DONE IAW GIV SRM 51.13.21 AND 51-42-00.
Step: 20.33
Completed
FOUND AND REMOVED SMALL AREA OF LIGHT SURFACE CORROSION
DIRECTLY BELOW -23 DOUBLER ON TAILCONE SKIN.
NDT MEASUREMENTS OF Al.L REWORKED AREAS WHERE CORROSION WAS
REMOVED WERE PERFORMED BY STS INC. REF LOG BOOK ENTRY WITH
W/O 12691 DATED 16 MARCH. 2016. LOWEST SKIN THICKNESS ON VERTICAL
STAB RECORDED WAS .054 AND LOWEST THICKNESS ON TAILCONE SKIN
WAS .072.
ALL WORK DONE IAW GIV SRM 51.13.21 AND 51-42-00.
Step: 20.3.4
Completed
REQUEST ENGINEERING EVALUATION FOR CONTINUED SERVICE OF
BLENDED AREAS WHERE CORROSION WAS REMOVED ON VERTICAL STAB
UNDER -23 DOUBLER. AND DIRECTLY BELOW DOUBLER ON TAILCONE
SKIN.
Step: 20.3.5
Completed
ENGINEERING DISPOSITION:
THE REMAINING THICKNESS AFTER CORROSION REMOVAL ON THE
1159CS20154 VERT STAB SKIN AND 1159821601 ANGI.E ARE STRUCTURALLY
ACCEPTABLE FOR CONTINUED SERVICE.
COMPLETE REMAINDER OF WORK TAW ASC 230.
Step: 20.3.6
Walling
APPLIED AIAMINF: TO ALL BARE METALAREAS. APPLIED
Insp
COUNTEILSINK/MLSMATCH FILL COAT OF EA934NA HYSOL, FEATHER
SANDED DOWN FLUSH AND APPLIED ALODINE AND PRIMER TO ALL
REMAINING BARE METAL.
RECEIVED NEW 1159SB20470-23 DOUBLER FROM GULFSTREAM SAVANNAH.
REFERENCE FAA FORM 8130-3 WITH FORM TRACKING6 20091028083347. AND
AUTHORIZATION./ ODA-511131-CE DATED OCT 28. 2009.
MATCH DRILLED NEW -23 DOUBLER USING EXLSTING DOUBLER AS GUIDE.
COUNTERSUNK AND DEBURRED HOLES, AND APPLIED ALODINE TO ALL
BARE METALAREAS.
INSTALLED -23 DOUBLER AND ALL ATTACHING FASTENERS WET WITH
PS870 SEALANT.
ALL WORK DONE IAW GULFSTREAM DRAWING 1159SB20470 AND
ENGINEERING DISPOSITION
WITH REFERENCE TO ASC 230.
Discrepancy: 20.4
DURING FLIGHT CONTROL PRE-THROWS NOTED PILOT CONTROL WHEEL DIFFICULT TO MOVE
LEFTAND CLICKING IN YOKE DURING ROTATION.
Resolution: RQCI
For detail description or the work complied with see the Work Order Detail report.
Unless otherwise indicated, all financial values listed in this document arc in US Dollars (USD).
GAC_WorkOrderPreliminaryInvoice.rm 2011
Page 85 of 123
Printed: 3/21/2016 11:35:41 AM
Rd 322
EFTA00590880
Bill To: JEGE LLC
WO 1/:
Invoice Number.
Billing Method
Hours
Rate
Total
Labor USD:
Pans USD:
Time and Material
Time and Material
ST
19.36
(S)
4132.00
42,555.52
41,091.33
Total USD:
43,646.85
EFTA00590881
EFTA00590882
EFTA00590883
EFTA00590884
EFTA00590885
EFTA00590886
EFTA00590887
EFTA00590888
EFTA00590889
EFTA00590890
EFTA00590891
EFTA00590892
EFTA00590893
EFTA00590894
EFTA00590895
EFTA00590896
EFTA00590897
EFTA00590898
EFTA00590899
EFTA00590900
EFTA00590901
EFTA00590902
EFTA00590903
EFTA00590904
EFTA00590905
EFTA00590906
EFTA00590907
EFTA00590908
EFTA00590909
EFTA00590910
EFTA00590911
EFTA00590912
EFTA00590913
EFTA00590914
EFTA00590915
EFTA00590916
EFTA00590917
EFTA00590918
Technical Artifacts (64)
View in Artifacts BrowserEmail addresses, URLs, phone numbers, and other technical indicators extracted from this document.
GPS
1.2311
1.2312GPS
1.2313
1.2315Phone
13074315Phone
14528775Phone
14528778Phone
14900332Phone
15033032Phone
2100136Phone
2212008Phone
2716008Phone
353-0505Phone
373-0349Phone
3857863Phone
4015239Phone
4100105Phone
4151514Phone
5004909Phone
5008447Phone
5008897Phone
5012120Phone
5120669Phone
5120716Phone
5121875Phone
547-2100136Phone
567-1575Phone
622-9210Phone
622-9210409Phone
7004609Phone
7018879Phone
7020116Phone
750-3000Phone
7783052Phone
8004388560Phone
8030131Phone
8069100Phone
8069197Phone
8083347Phone
822-0836Phone
9082387Phone
929-2094Phone
9821504Phone
9821601SWIFT/BIC
AVIATIONSWIFT/BIC
CHASUS33SWIFT/BIC
CORRODEDSWIFT/BIC
REPLACEDSWIFT/BIC
RESOVOIRSWIFT/BIC
SAVANNAHSWIFT/BIC
SHIPMENTSWIFT/BIC
SOUTHERNSWIFT/BIC
TEMPERATURETail #
N1ATTail #
N212Wire Ref
REF: GULFSTREAMWire Ref
REF: SQUAWKWire Ref
REFERENCEWire Ref
Ref: 1159SC1204Wire Ref
ReferenceWire Ref
TRANSFER NUMBERWire Ref
WIRE
ResolutionWire Ref
WIRE HARNESSWire Ref
Wire RemittanceRelated Documents (6)
DOJ Data Set 10CorrespondenceUnknown
EFTA Document EFTA02078835
0p
DOJ Data Set 10CorrespondenceUnknown
EFTA Document EFTA02097596
0p
DOJ Data Set 11OtherUnknown
EFTA02225369
1p
DOJ Data Set 10CorrespondenceUnknown
EFTA Document EFTA01731630
0p
DOJ Data Set 11OtherUnknown
EFTA02327165
1p
DOJ Data Set 9OtherUnknown
From: Larry Visoski
1p
Forum Discussions
This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.
Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.