Case File
efta-efta01074467DOJ Data Set 9OtherWork Order Snapshot
Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta01074467
Pages
4
Persons
0
Integrity
No Hash Available
Extracted Text (OCR)
Text extracted via OCR from the original document. May contain errors from the scanning process.
Work Order Snapshot
Work Order #
14887
Aircraft
N62MS
1 ADMINISTRATIVE ITEMS
1
1
AIRCRAFT FLIGHT LOG (AFL) DATA EXTRACTION, REQUIRED AFL MAINTENANCE ENTRIES AND ISSUANCE OF
Completed
MAINTENANCE/AIRWORTHINESS RELEASE (FAR 43.9, 43.11 OR 135.443, AS APPLICABLE).
Resolution
FOR BILLING PURPOSES ONLY.
I
2
GENERATION OF REQUIRED MAINTENANCE LOGBOOK ENTRIES FOR AIRFRAME, ENGINES AND AUXILIARY
Completed
POWER UNIT, AS APPLICABLE.
Resob0on
FOR BILLING PURPOSES ONLY.
I
3
PROCESSING OF COMPLETED WORK INSTRUCTION CARDS WITH THE CUSTOMER'S MAINTENANCE TRACKING
Completed
PROVIDER FOR ALL MAINTENANCE ACTIVITIES (FAR 91.417 OR 135.439, AS APPLICABLE).
Resolution
FOR BILLING PURPOSES ONLY.
I
4
FREIGHT CHARGES
Completed
ReRiuti0n
FREIGHT CHARGES
I
5
COMPLY WITH TOUCH UP CLEANING AFTER MAINTENANCE
Completed
Resokition
COMPLY WITH TOUCH UP CLEANING AFTER MAINTENANCE
I
6
USE NEXT
Completed
Resolution
USE NEC'
I
7
MISC RECORDS AND FILE STORAGE
Completed
Resolution
BILLING ONLY
I
8
MISC. MATERIAL / WASTE DISPOSAL FEE
Completed
Resolution
BILLING ONLY
2 CUSTOMER REQUESTED MAINTENANCE
2
I
COMPLY WITH PRELIMINARY INSPECTION AS REQUIRED BY FAR 145.211(c) (1) (ii).
Completed
Resolution
COMPLIED WITH PRELIMINARY INSPECTION WITH NO DEFECTS NOTED.
I
TAKE PRELIM VIDEO OF AIRCRAFT PER CUSTOMER REQUEST.
Completed
2
2
UPON COMPLETION OF MAINTENANCE THE PERFORMANCE OF A WALK AROUND CHECK OF THE AIRCRAFT IS
Completed
REQUIRED BY THE AUTHORIZED INSPECTOR APPROVING THE AIRCRAFT FOR RETURN TO SERVICE.
Resolution
COMPLIED WITH WALKAROUND INSPECTION.
2
3
COMPLY WITH MAINTENANCE RELEASE TASKS, IF REQUIRED.
Completed
Resolution
COMPLIED WITH MAINTENANCE RELEASE TASKS FOR RETURN TO SERVICE.
I
REMOVE RED 'AIRCRAFT NOT AIRWORTHY" TAG. (FORM 1650) FROM AIRCRAFT.
Completed
2
4
COMPLY WITH REMOVING RECORDS UPON ARRIVAL (TAKING THEM UPSTAIRS)
Completed
Resolution
COMPLIED WITH REMOVING RECORDS
2
5
SPOT DETAIL IN PREPARATION FOR PHOTO SHOOT ON SEPTEMBER 11,2015.
Completed
Resolution
COMPLIED WITH SPOT DETAIL FOR PHOTO SHOOT
2
6
UPON COMPLETION OF MAINTENANCE THE PERFORMANCE OF A WALK MOUND CHECK OF THE AIRCRAFT IS
Completed
REQUIRED BY THE AUTHORIZED INSPECTOR APPROVING THE AIRCRAFT FOR RETURN TO SERVICE.
Resolution
DUPLICATE SQUAWK SEE SQUAWK 2.2 THIS WORK ORDER.
2
7
CHECK MAIN BATTERY STATE OF CHARGE PRIOR TO NEXT FLIGHT.
Completed
Resolution
CHECKED BATTERY STATE OF CHARGE, BOTH BATTERIES, 26.3 VOLTS.
2
8
UPDATE CMP CODE 346025 AND COMPLY WITH FMS NAV DATABASE UPDATE DUE 9.16.2015.
Resobtron
DO NOT WORK PER CUSTOMER REQUEST.
Monday, Arch 21, 2016
Completed
Page a4
EFTA01074467
Work Order Snapshot
Work Osier #
14887
Aircraft
N62MS
2
9
COMPLY WITH 28 DAY ENGINE PRESERVATION RUN
Completed
DUE 105.2015.
Resokton
COMPLIED WITH 28 DAY ENGINE PRESERVATION RUN. APU HOURS 1852.0
I
RECORD APU HOURS AFTER 28 DAY ENGINE PRESERVATION RUN
Completed
2
10
UPDATE CMP CODE 345004 AND COMPLY WITH FAR 91.171(bX1) 30 DAY VOR CHECK DUE 9-19-2015
Completed
RECORD THE FOLLOWING INFORMATION IN THE RESOLUTION:
-BEARING TRANSMITTED
-BEARING ERROR 81
-BEARING ERROR 82
NOTE: THE INSPECTOR RELEASING THE AIRCRAFT WILL ENTER RESULTS IN THE AFL
Resolutton
COMPLIED WITH FAR 91.171(b)(I) 30 DAY VOR CHECK.
TEST SIGNAL BEARING TRANSMITTED, 210 DEGREES ON 108.00 MHZ.
-BEARING ERROR *1 WAS ZERO DEGREES.
-BEARING ERROR #2 WAS ZERO DEGREES.
-BEARING ERROR #3 WAS ZERO DEGREES.
UPDATED CMP CODE 345004.
2
11
CUSTOMER REQUESTS THE WORK PACKAGE FOR WORK COMPLETED AT GULFSTREAM - WESTFIELD BE AUDITED.
Completed
Resolution
REVIEWED WORK PACKAGE TO INCLUDE GULFSTREAM WORK ORDER, CMP CARDS, PARTS CERTIFICATIONS AND CND
DATABASE UPDATES. NO DISCREPANCIES WERE NOTED.
2
12
ASSIST WITH PHOTO SHOOT
Completed
Re.$0/utiOn
ASSISTED WITH PHOTO SHOOT AS REQUIRED,
2
13
TOUCH UP CLEAN INTERIOR AFTER PHOTOSHOOT
Completed
Resolution
TOUCH UP ri FAN INTERIOR AFTER PHOTOSHOOT AS REQUIRED.
2
14
PLEASE READ THE CMC TO DETERMINE THE LATEST APU TIME AND SEND TO PHIL MORGAN.
Completed
Resolubon
• THE LATEST APU TIME OFF CMC IS 1850.5 AND SENT IT TO PHIL MORGAN
2
15
PLEASE OBTAIN THE SHIP'S ELT DATA AND SEND TO PHIL MORGAN FOR NOAA/SARSAT REGISTRATION.
Completed
Resolution
ELT INFO. MODEL C406.2, PN 453-5000-(366), SN 03976, BATT EXP APRIL 2018.
15 DIGIT HEX ID 2DC7S 02A10 FFBFF
ELT MODE S HEX CODE A81508, IS CORRECT FOR TAIL NUMBER. REQUEST COMPLIED WITH.
1
ELT IS REMOVED MD IN AVIONICS SHOP TO HAVE THE A/C ELT DATA SENT TO PHIL MORGAN.
Completed
2
INSTALL ELT INTO BAGGAGE AREA ABOVE WATER CLOSET.
Completed
3
ELT INFO. MODEL C406.2, PN 453.5000-(366), SN 03976, BATT EXP APRIL 2018.
Completed
IS DIGIT HEX ID 2DC7S 02A10 FFBFF
ELT MODE S HEX CODE A81508, IS CORRECT FOR TAIL NUMBER.
2
16
FQMS MAINT BLUE CAS MESSAGE PRESENT AND RIGHT WING FUEL QUANTITY NOT STABLE.
Completed
Resod/60n
CHECKED AND CLEARED FAULTS ON GROUND SERVICE CONTROL PANEL MD GROUND SERVICE OIL PANEL PERFORMED
FUEL GROUND SERVICE CONTROL PANEL OPERATIONAL TEST REFERENCING G550 AMM 28-4109 REV. 24 FEB IS, 2015.
AFTER TWO HOURS OF ENGINE RUNS MD AIRCRAFT TAXIING, FQMS MAINT BLUE CAS MESSAGE WAS NEVER PRESENT,
RIGHT WING FUEL QUANTITY WAS STABLE AND GSCP & GSOP HAD NO FAULTS.
1
FOUND TWO CODES IN THE FQMS UNDER FUEL.
Completed
28414 R FQMS STORED FAULT
28417 RIGHT SENSOR FAULT.
2
CLEAR EXISTING FAULTS ON GROUND SERVICE CONTROL PANEL AND GROUND SERVICE OIL PANEL. PERFORM FUEL
Completed
GROUND SERVICE CONTROL PANEL OPERATIONAL TEST REFERENCING G550 AMM 21.41-09 REV. AUGUST 31/03.
2
17
PASSENGER ADDRESS SYSTEM IS WEAK, DOES NOT APPEAR ALL SPEAKERS ARE OPERATING.
Completed
Resolution
CHECKED PASSENGER ADDRESS SYSTEM, FOUND ALL SPEAKERS OPERATIONAL AND ABOVE NORMAL VOLUME LEVEL.
I
CHECKED PASSENGER ADDRESS SYSTEM, FOUND ALL SPEAKERS OPERATIONAL AND ABOVE NORMAL VOLUME LEVEL.
Completed
2
18
LEFT POWER LEVER HUNTING WITH AUTO THROTTLES ENGAGED.
Completed
THE POWER LEVER TARGET GENERATED BY LAC HUNTS AND LOOKS LIKE THE AIRCRAFT DOES NOT KNOW
WHERE PLA IS AT HIGH POWER SETTINGS.
SUSPECT POWER LEVER QUADRANT
RecORMOn
PERFORMED FAN AIR VALVE FUNCTIONAL CHECK REF-G550-AMM-36-14-00, NO DEFECTS NOTED. REMOVED THROTTLE
QUADRANT P/N 1159SCF552-5 S/N B0261 AND INSTALLED SERVICEABLE THROTTLE QUADRANT P/N 1159SCF552-5 S/N
80511 FROM NSO8P REF W.O. 14923 SQWK 2.15 LAW CMP 761001. UPDATED CMP CODE 223005, 276203, 277002,
710025, 710026, 783007 & 783008.
Monday, Arch 24 2016
Page 2O'4
EFTA01074468
Work Order Snapshot
Work Order #
14887
Aircraft
N62MS
1
REMOVE LEFT PYLON PANEL (411G8), TO PERFORM FAN AIR VALVE - RJCTIONAL CHECK.
Completed
2
REMOVE LEFT PYLON PANEL (411HT) TO ACCESS FAN AIR VALVE TO PERFORM FUNCTIONAL CHECK.
Completed
3
INSTALL LEFT PYLON PANEL (411GB) AFTER FAN AIR VALVE CHECK COMPLETE
Completed
4
INSTALL LEFT PYLON PANEL (411HT) AFTER FAN AIR VALVE CHECK.
Completed
S
PERFORM FAN AIR VALVE - FUNCTIONAL CHECK, REF-GSSOAMM-36-14-00
Completed
6
INSTALL L/H LOWER PYLON BOARD (411G8), AND 1/H UPPER PYLON BOARD (411HT),
Completed
AIRCRAFT REQUIRES REPOSMONING.
7
REMOVE L/H UPPER PYLON BOARD (411HT) AND L/H LOWER PYLON BOMD (411GB),
Completed
IN ORDER TO COMPLY WITH ITEM/SQUAWK a 2.18.
8
INSTALL THROTTLE QUADRANT FROM NS08P REF W.O. 14923 SQWK 2.15 UAW G-550 MAINT MANUAL 76.1001.
Completed
2
19
ADM #2 INDICATES 80 FEET LOW 0 FL430. ALL FOUR PITOT PROBES JUST REPLACED.
Completed
ADVISE
Resobtion
[CSF) PERFORMED ADM ACCURACY CHECK UAW GAC GSSO MAINT MANUAL 34.13-00. ADM #2 CHECKED GOOD.
CUSTOMER REQUESTED SWAPPING #2 AND *3 ADM FOR MAINT COW. COMPLIED WIN SWAP. PERFORMED PITOT /
STATIC LEAK CHECK UAW GSSO MAINT MANUAL 34.13-00. CHECKED GOOD. NO CHANGE TO ORIGINAL FAR 91.411 DATE
(0301-15). UPDATED CMP CODES 341021 AND 341022.
1
PERFORMED ADM ACCURACY CHECK UAW GAC GSSO MAINT MANUAL 34-13-00. ADM a2 CHECKED GOOD.
Completed
2
PERFROM RADOME TO STRUCTURE PERIMETER STEP - DETAILED INSPECTION UAW GSSO MAINT MANUAL 5302-01.
Completed
2
20
UPDATE CMP CODE 970991 AND COMPLY WITH ASC 99A AILERON AND ELEVATOR POWER DISCONNECT•
Completed
REMOVAL
Resoji0on
PREVIOUSLY COMPLIED WITH BY GAC, REMOVED 24 MONTH FREQUENCY FROM CMP. NO FURTHER ACTION IS REQUIRED.
2
21
UPDATE CMP CODE 321006 AND COMPLY WITH MAIN LANDING GEAR (RIGHT). LUBRICATION.
Completed
Resolution
COMPLIED WITH MAIN LANDING GEM (RIGHT) LUBRICATION AND UPDATED GIP CODE 321006.
2
22
UPDATE CMP CODE 321005 AND COMPLY WITH MAIN LANDING GEAR (LEFT) • LUBRICATION.
Completed
Resolution
COMPLIED WITH MAIN LANDING GEAR (LEFT) - LUBRICATION AND UPDATED CMP CODE 321005.
2
23
UPDATE CMP CODE 322004 AND COMPLY WITH NOSE LANDING GEAR • LUBRICATION.
Completed
Resolution
COMPLIED WITH NOSE LANDING GEM LUBRICATION AND UPDATED CMP CODE 322004.
2
24
UPDATE CMP CODE 570017 AND COMPLY WITH WING REAR BEAM AT AILERON (WS 386 • WS 479) LEFT •
Completed
ZONAL INSPECTION.
Resolunon
COMPLIED WITH WING REAR BEAM AT AILERON (WS 386 WS 479) LEFT - ZONAL INSPECTION;.UPDATED CMP CODE
570017
2
25
UPDATE CMP CODE 570018 AND COMPLY WITH WING REAR BEAM AT AILERON (WS 386 • WS 479) RIGHT -
Completed
ZONAL INSPECTION.
Resolution
UPDATED CMP CODE 570018 AND COMPLIED WITH WING REM BEAM AT AILERON (WS 386 WS 479) RIGHT - ZONAL
INSPECTION.
2
26
UPDATE CMP CODE 262623 AND COMPLY WITH PORTABLE HALON FIRE EXTINGUISHER (AFT
CABIN,HYDROSTATIC) - FUNCTIONAL TEST.
UPDATE CMP CODE 262624 AND COMPLY WITH PORTABLE HALON FIRE EXTINGUISHER (AFT CABIN) • FINAL
PHASE RESTORE.
Resolution
REMOVED AND REPLACED AFT CABIN PORTABLE HALON FIRE EXTINGUISHER WITH NEW. UPDATED CMP CODES 262620,
262623, AND 262624. MOUNTED NEW BRACKET AND FIRE EXTINGUISHER IN THE SAME LOCATION AS THE ORIGINAL
USING THE SAME HOLE PROVISIONS AND HARDWARE M ORIGINAL
Discrepancy Steps...
2.26.1 - REMOVE AND REPLACE AFT CABIN PORTABLE HALON FIRE EXTINGUISHER WITH NEW. UPDATE CMP CODES
262620 AND 262623.
2.26.2 - MOUNT NEW FIRE EXTINGUISHER BRACKET TO CABINET DOOR USING ORIGINAL MOUNT HOLES PROVIDED.
2.26.3 - UPDATE CMP CODE 262624 AND COMPLY WITH PORTABLE HALON FIRE EXTINGUISHER (AFT CABIN) FINAL
PHASE RESTORE.
Completed
1
REMOVE AND REPLACE AFT CABIN PORTABLE HALON FIRE EXTINGUISHER WITH NEW. UPDATE CMP CODES 262620
Completed
AND 262623.
2
MOUNT NEW FIRE EXTINGUISHER BRACKET TO CABINET DOOR USING ORIGINAL MOUNT HOLES PROVIDED.
Completed
Monday, Mitch 21, 2016
Page 3 O'4
EFTA01074469
Work Order Snapshot
Work Order #
14887
Aircraft
N62MS
3
UPDATE CMP CODE 262624 AND COMPLY WITH PORTABLE HALON FIRE EXTINGUISHER (AFT CABIN) FINAL PHASE
RESTORE.
Completed
2
27
RESEARCH LAST INTERIOR UPGRADE AND EMAIL PHIL.
Completed
Resolution
COMPLIED WITH, BILLING ONLY.
2
28
RESEARCH ENGINE SB STATUS FOR IGNITER PLUGS.
Completed
Resobtron
ENTERED IN ERROR.
2
29
PRC SEAL LH AND RH UPPER AND LOWER AILERON COVE PANELS
Completed
Resolution
SEALED L/H AND R/H UPPER AND LOWER AILERON COVE PANELS IAW GAC GSS0 N.M. CHP 20.40.00. NO OTHER
DEFECTS NOTED.
2
30
TOUCH UP PAINT ON L/H AND R/H UPPER AND LOWER AILERON COVE PANELS.
Completed
ResobOon
COMPLY WITH AT A LATER DATE
2
31
COMPLY WITH INSTALLING ENGINE COVERS, PITOT AND STATIC COVERS AS NEEDED FOR OUTSIDE STORAGE
Completed
Resolution
(REMOVE COVERS WHEN NEEDED).
COMPLIED WITH.
2
32
COMPLY WITH A TOUCH UP BEFORE SHOWING AND AFTER SHOWING AS NEEDED
Completed
ReSoluten
COMPLIED WITH
2
33
UPDATE CMP CODE 262624 AND COMPLY WITH PORTABLE HALON FIRE EXTINGUISHER (AFT CABIN) - FINAL
Completed
PHASE RESTORE.
Resolution
SEE SQUAWK 2.26, THIS' .O.
Monday, Mark 21, 2015
Page 4 of 4
EFTA01074470
Technical Artifacts (4)
View in Artifacts BrowserEmail addresses, URLs, phone numbers, and other technical indicators extracted from this document.
Phone
453-5000Phone
453.5000Tail #
N62MSWire Ref
REFERENCINGForum Discussions
This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.
Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.