14 It) THOMAS A. FENNIM AN ARCH ITECT Facade Inspection & Safety Program Cycle 8A Report for 9 East 7151 Street New York, NY 10021 August 2015 ONE UNION SQUARE WEST. SUITE 501. NEW YORK. NEW YORK 10003 TEL FAX 212.414.0249 EFTA01083963 9 East 71" Street Facade Inspection & Safety Program August 2015 Cycle 8A As per our agreement with the Owner of the subject building, we have completed a critical examination of the subject building in order to comply with NYC Construction Code section §28-302 that mandates the periodic inspection of the exterior walls and appurtenances of buildings greater than six stories in height by a Qualified Exterior Wall Inspector (QEWI). The inspection was performed and completed in accordance with RCNY 103.04. Executive Overview Summary of Findings: The building is currently inspected as Safe. Conclusions and Recommendations: Based on the Safe status of the building there are no immediate recommendations required within the next 5 years. Categorization of Building: SAFE Report of Critical Examination Property Information A. Address of Critical Examination: 9 East 71" Street, New York, NY 10021 Nearest cross streets to the building: Between Fifth Avenue & Madison Avenue BIN#: 1041354 Tax Block: 1386 Tax Lot: 10 Zoning District, Map: RSB, Map 8c B. Building Owner: Maple Inc 9 East 71" Street New York, NY 10021 Richard Kahn, Treasurer T: E: C. Building Description: Number of Stories: 7 stories + cellar Height of Building: 120 feet Plan Dimensions: 50%0" wide x 921-0" deep Certificate of Occupancy number: #101428 Usage: Residential Age of Building: 1910 Type of exterior construction: Stone & Brick Masonry Landmark Status: Upper East Side Historic District D. Settlements, repairs, and revisions to exterior enclosures since previous report None 2 of 8 EFTA01083964 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle SA Methods Used to Conduct Inspection E. Critical Examination Procedures 1. Review of Prior Reports: 2. Visual Examinations: 3. Physical Examinations F. Description of Examinations: 1. Riggers Information: 3. Location Diagram: 4. Date of Inspections: Summary of Findings G. Conditions Observed Prior to examining the exterior walls, the most recent report and any available previous reports were carefully reviewed. Binoculars and a telescopic camera were used to conduct a visual inspection of all exterior facades. These include the 71' Street facade, East, West and Rear facades. A physical examination (close-up inspection) was conducted via scaffold / and terraces from grade to top of the 71'' Street facade. The location of the physical examination is noted on the attached plan. Andrew Rosenwach Herbert Rose Inc. 40-25 Crescent St. Lon Island Ci , NY 11101 T: #5739 Refer to attached plot plan. June 24, 2015 1. Significant Deterioration & Movement: None. 2. Apparent Water-tightness: The roofs, bulkheads & facades inspected during the critical examination appear, by the methods used to conduct the inspection, to be watertight. The building Manager reported that there are currently no active leaks attributed to the building envelope. 3. Classification of Conditions: Unsafe Conditions: None; No UNSAFE conditions were observed. SWARMP Conditions: The following conditions were noted to be safe with a repair and maintenance program (SWARMP). These conditions should be repaired within five years (prior to the next critical examination) to ensure they do not deteriorate into unsafe conditions. Should these conditions not be remedied prior to the next critical examination, they will automatically be deemed unsafe. The owner of the building is responsible for ensuring that the conditions described in the critical examination report as SWARMP are repaired and all actions recommended by the QEWI are completed within the time frame recommended by the QEWI, and are not left to deteriorate into unsafe conditions before the next critical examination. It is the owner's responsibility to notify the Department of any deviation from the timeframe to make corrections as specified in QEWI's report. Such notification shall be accompanied by supporting documents from the QEWI justifying the request for a new time frame. 3 oft EFTA01083965 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle SA None; No SWARMP conditions were observed. Safe Conditions: The following conditions were noted to be safe. These conditions need not be addressed at their current state, but should be tracked to ensure they do not begin to deteriorate into unsafe conditions after a five-year period. Condition Façade Floor Photo Open mortar joints - South Facade 3'd 8 and 4th 9 Open joints at metal flashing - 4ih Floor Cornice at' 10 South Facade 4. Exterior Appurtenances: The following exterior appurtenances were noted to be safe. Exterior fixtures Parapets Copings Guard rails Balcony enclosures Window frames (including hardware and lights) Window guards Communication equipment (ie: wires, satellite dishes, etc) 5. Safe Conditions Requiring Monitoring / Routine Maintenance: None. H. Causes of SIVARMP Conditions: N/A. I. Status of Exterior Maintenance: N/A Report of Findings and Recommendations .1 Comparison of Cycle 7 & Cycle 8 Reports: Previous cycle report status: SAFE Initial Filing Date: February 17, 2012 1. Open ECB Violations: None. K. Schedule of Repairs and Maintenance of SWARMP Items: 1. Repair Items: N/A; No SWARMP items. L Required Permits: N/A M. Photographs: Refer to attached photograph& N. The classification of the Building for the Current Report Filing is: Professional Seal and Signature SAFE 4 of 8 EFTA01083966 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle SA This report is prepared solely to comply with Section §28-302 of the Administrative Code of the City of New York in accordance with the rules and procedures of the Commissioner of Buildings of the City of New York. Opinions expressed herein reflect only conditions present at the time of Critical Examination. The report is not intended as a specification for repair nor is it to be used as such to obtain bids for repair. The Architect (QEWI) assumes no responsibility for the adequacy of design or construction of the original building, nor for the adequacy of alterations, repairs or maintenance of this building in the past, present or future by Contractors or maintenance personnel. The building was inspected for compliance with the Facade Inspection and Safety Program requirements only and this report should not be construed as presentation as to the conditions of any other building components including but not limited to the roof structure, drainage system, flashings, stairs, exits or elevator system. A copy of this report has been submitted to the Owner prior to filing with the Department of Buildings. Signed: Date: Thomas A. Fenniman, Architect Appendices 1. Photographs 2. Location (plot plan) diagram 3. BIS Property Profile Overview 4. BIS Facades Page 5 of 8 EFTA01083967 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle SA Photographs (06/24/2015) I . View of South (East 7151 Street) façade. 6 of 8 EFTA01083968 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle SA 2. Detail view of Southeast Corner (East 7Ig Street) facade. 3. View of east side of east chimney and elevator bulkhead. 7 of 8 EFTA01083969 9 East 71" Street Facade Inspection & Safety Program August 2015 Cycle SA 4. Detail view of 4ib Floor Balustrade. 5. View of 4th floor cornice brackets in good condition. 8 of 8 EFTA01083970 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle 8A 6. Replacement and patched stone at 4ib floor cornice. 7. Patched stone at 3n1 Floor southwest corner bandcourse. 9 of 8 EFTA01083971 9 East 71" Street Facade Inspection & Safety Program August 2015 Cycle SA 8. Partial open joint at upper portion of 4ih floor band course. 9. Partial open mortar joint at 3" Floor. 10 of 8 EFTA01083972 9 East 71" Street Facade Inspection & Safety Program August 2015 Cycle SA 10. Partial open joint at metal flashing above 4th floor cornice. 11. Detail of carved stonework above entrance in good condition. I1 of g EFTA01083973 9 East 71" Street Façade Inspection & Safety Program August 2015 Cycle 8A 12. Evidence of rusted metal at underside of 3rd Floor metalwork. 13. West face of southeast chimney. 12 of 8 EFTA01083974 9 East 7I" Street Facade Inspection & Safety Program August 20t5 Cycle SA 14. South view towards southwest chimney. 15. Main flue at northeast corner. I3of8 EFTA01083975 August 2015 Cycle gA 16. North face of elevator bulkhead with metal flue in good condition. 9 East 71" Street Façade Inspection & Safety Program I WWI I ts,gt I anti 3,31111/ ---agggggaaaepa4L...:yd J-318/a is i ig 17. Southwest corner of Elevator Bulkhead. as 14 of 8 EFTA01083976

Technical Artifacts (2)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

FaxFAX 212.414.0249
Phone212.414.0249

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.