Skip to main content
Skip to content
Case File
efta-efta01735386DOJ Data Set 10Correspondence

EFTA Document EFTA01735386

Date
Unknown
Source
DOJ Data Set 10
Reference
efta-efta01735386
Pages
0
Persons
0
Integrity
No Hash Available
Loading PDF viewer...

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
SIEMENS Field Panel Web Server weenier.. The Field Panel Web Server provides a Web-based Graphical User Interface (GUI) compatible with BACnet® networks. Using the Web Server, the facility operator can easily monitor and control the APOGEE® Building Automation System through an intuitive Web-based user interface. Description The Web Server allows system-wide access through a single log-in. Web pages are populated with data from any BACnet IP-enabled PXC controller and associated Field Level Network (FLN) devices. The Web Server runs on standard PXC controllers, eliminating the need for separate high-cost 'web appliances' or dedicated web servers. This means that the same APOGEE field panel can serve as an automation controller, with full building automation and I/O features, and provide the user with system information and access via a web browser. The use of web services for communication ensures that any web browser with Adobe® Flash® is able to access the Field Panel Web Server. A Web Server-enabled controller can accommodate an unlimited number of user accounts and simultaneous users. Technical Specification Sheet Rev. 1, December 2010 Security The Web Server is secured from IT security threats by means of password-protected operator access. The Web Server uses password encryption. User accounts can be individually configured for customized access privileges. Operator sessions may be configured to automatically log off during periods of user inactivity. The Field Panel Web Server is compatible with standard IT security policies and tools established within a particular facility, and can be protected within that environment. Browser/Client Requirements • Session cookies enabled • Adobe® Flash® Player Plug-in 10.1 or later installed Features The Field Panel Web Server encompasses the following operator applications: • Graphical Monitoring and Control • Network Layout • System Status Bar • Alarm Status and Acknowledgement • Point Commanding • Scheduling • Reporting • Graphical Trend Display • User Interface Customization • Online Database Editing Document No. 149-1000 Page 1 of 6 EFTA_R1_00017740 EFTA01735386 Graphics INIECIWN --11 =MI FAIT a-4; . • I • Customized system graphics Live animation of equipment Real-time point values and status updates • Link to system schedule and% or historical trend Network Layout C, • v • e: et •!,•••.t, Ahul • IT. S•• A111111 OGRAM:TOTKW • IL Sie bl.t..1 AMU ChoNV • L See BLDG1 AHUI worn/ BLDG! AHUI PAH DLOG1 AHUI PAT • dr., Graphics • 71 MST•TUE.02 • ES12.I3TECOI • I_ Ssernens13 00131 Local **Trends Schedules ▪ Gre•Pmcs • f.PITUNI 513.A1EC03 ..S13.ATECO4 513.TEC01 . 1 S13.TEC02 U • View network layout • View BACNET MSITP and P1 FLNs • Navigate to other Web-enabled panels • Search database for individual points System Status Bar 0 • • Visual indication of new alarms and unacknowledged alarms • Visual indication of out of service, faults, and failed devices Alarm Status and Acknowledgement •Los Repo.. • Ability to view, filter, and acknowledge system alarms from a single page Point Commanding • Change point values • Place points "Out of Service" • Command BACnet MS/TP and P1 FLN points Scheduling ▪ .•••••• >0.10 1611 ••• 0111.0. • View schedules in a daily, weekly, or monthly view • Add and delete schedules • Create exceptions for existing schedules Page 2 of 6 Siemens Industry, Inc. EFTA_R1_00017741 EFTA01735387 Reporting User Interface Customization • Generate Point Log Report with multiple filters Graphical Trend Display • Ability to view one display • Ability to view raw CSV file or more trends on a single data values and export to • Print trend graph to network printers FM Sae 10 il l Isnstage English Data Rene:hate. w" Altai coat ulitek mem coot OC5Cdor D•vre Fare Cool • Re:et to Default FAA CVC, • Custom Welcome Page • User interface translatable to any browser- supported language • Ability to customize font sizes and display colors Online Database Editing • Database Configuration o Add/ Modify/ Delete points o Add/ Modify! Delete trend definitions o Add/ Modify/ Delete Event Enrollment Objects o Add/ Modify/ Delete Notification Class Objects • Schedule o Add/ Modify! Delete schedules o Add/ Modify/ Delete Command Objects o Add! Modify! Delete Calendar Objects • Custom Program Editor o Add/ Modify/ Delete programs o View and clear program trace bits o View disabled, unresolved, and comment lines FLN Devices o Add/ Modify/ Delete FLN Devices o Set and Release TEC Initial values • User Account o Add! Modify/ Delete user accounts o Change user passwords Siemens Industry. Inc Page 3 of 6 EFTA_R1_00017742 EFTA01735388 Graphics Creation and Editing • Graphics configuration tool allows remote\ offline creation, modification, and deletion of graphics. • Library of predefined graphic backgrounds • Ability to import standard image formats (.png, .jpg, and, .gif) Page 4 of 6 Siemens Industry, Inc. EFTA_R1_00017743 EFTA01735389 Field Panel Web Server At least one PXC Compact 36 or PXC Modular controller with firmware 3.2.2 is required on each WEB Browser PXC 36 with Web Services Enabled I. BACnet MS/TP P1 FLN Pc 16/24 with Web Services Enabled network. Data from every controller that has the Web Services license enabled will be automatically displayed. Li WEB Browser PXC Modular a with Web Services Enabled BACnet MS/TP/ P1 FLN ± I =MI Inlij Figure 1 Field Panel Web Server Siemens Industry. Inc Page 5 of 6 EFTA_R1_00017744 EFTA01735390 Specifications Supported BACnet Field Panels BACnet IP-based PXC Modular BACnet IP-based PXC Compact 16/24/36 Note: At least one PXC Modular or PXC 36 is required on each network Web Browser Internet Explorer 6.0 or later, or Firefox 3.6 or later with Adobe Flash Player Plug-in 10.1 or later is supported Any browser capable of running and displaying Adobe Flash Player Plug-in 10.1 or later is compatible. Ordering Information Description Part Number SSN Field Panel Web Services License LSM-FPWEB P55801-Y104 Field Panel Graphic Editor 571-214 555801-Y139 Information in this document is based on specifications believed coned at the time of publication. The right is reserved to make changes as design improvements are introduced. APOGEE is a registered trademark of Siemens Industry. Inc. 2010 Siemens Industry. Inc. Siemens Industry. Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Country of Origin: US Page 6 of 6 EFTA_R1_00017745 EFTA01735391

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.